CS Paper Radar

Pulseflow: PPG Counterfactual Generation Via Latent Transport

Hung Manh Pham, Dong Ma, Bin Zhu, Pan Zhou

cs.LG ·submitted 2026-09-27 12:09 UTC · v1
code/data

Abstract

Photoplethysmography (PPG) has become an important modality for continuous cardiovascular monitoring, including atrial fibrillation (AF) detection. However, labeled AF recordings remain limited in many clinical settings, making model adaptation difficult when only limited target data are available. Generative modeling offers a natural way to alleviate this scarcity by synthesizing additional AF signals. Existing approaches, however, mainly generate samples that match the target condition without explicitly modeling how an observed source recording should be transformed, making it difficult to leverage abundant source recordings from a specific population or cohort for targeted augmentation. We introduce PulseFlow, a source-conditioned counterfactual generation framework that combines conditional representation learning with invertible latent transport to edit cardiac rhythm while retaining information from the source. Experiments across two clinical cohorts demonstrate effective rhythm transformation, measurable source correspondence, and improved AF classification under limited labels.

Closest papers

Nearest neighbours by meaning across the whole index.

Represent, Then Generate: Multimodal-Conditioned Time-Series Generation under Irregular Missingness

cs.LG ·2026-08-12 ·Haochen Zhang, Jiaheng Guo, Yu-Chao Huang, Nicholas Konz, Tianlong Chen
similarity 0.66
Abstract · 17 pages, 5 figures

Continuous physiological time series underpin modern clinical monitoring, yet many of the most informative signals are invasive, expensive, or simply unavailable for a given patient. Conditional generation offers a remedy: an absent signal can be synthesized from co-recorded signals and routine clinical variables. Existing generators, however, are built around a single conditioning modality and degrade when forced to handle the heterogeneous, irregularly missing mix of time-variant signals and static covariates seen in practice. We propose ReCoGen (Represent Conditions, then Generate), a two-stage framework that decouples multimodal condition representation from target generation. Stage I trains one masked autoencoder per modality, distilling each time-variant condition into a compact and missingness-tolerant token sequence. Stage II trains a flow-matching generator that fuses these tokens with static conditions to synthesize the target signal. Across three physiological benchmarks, including continuous glucose monitoring on AI-READI and arterial blood pressure generation on MIMIC-III and MIMIC-IV, ReCoGen attains the best downstream utility on all sixteen (dataset, task, metric) settings, surpassing six representative conditional generators; on thirteen of them its utility also reaches or exceeds the utility measured on the real signal, a reference we read as an approximate anchor rather than a ceiling. Ablations trace the gains to the conditioning path: learnable cross-attention over the frozen per-modality encoders, and a dual token-plus-AdaLN route for the static conditions. ReCoGen thus turns routinely collected signals into informative surrogates for invasive or unavailable ones, a step toward less invasive, lower-cost continuous clinical monitoring.

0.10

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.65
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

Generating Chest X-Ray Counterfactuals by Specialising Foundation Image Models

cs.CV ·2026-09-21 ·Xiaodan Xing, Rajat R. Rasal, Julia A. Meister, Sara Ghorayeb, Galvin Khara +1 more
code/data similarity 0.65
Abstract · 32 pages, 6 figures, 16 tables. Code: https://github.com/GSK-AI/RadCF/

Counterfactual image generation answers questions about how a subject would have looked under retrospective, hypothetical scenarios. Recent methods have improved perceptual quality, identity preservation and faithfulness to an underlying causal model, but their adoption in healthcare is limited by scarce annotated data, distribution shift between datasets, and mismatches between pretrained generative models and those required for counterfactual inference. We propose specialisation, a data and parameter-efficient framework for adapting pretrained, non-causal generative models into causal mechanisms under distribution shift. Based on this framework, we train a radiology counterfactual image generation model, called RadCF, using latent flow matching. We validate our approach on three chest X-ray datasets spanning different dataset shifts, data volumes, and counterfactual questions, associated with challenging, highly-localised interventions. Our results show that RadCF and specialisation improve counterfactual soundness over existing methods while being data and parameter efficient, and that the resulting counterfactuals can detect and mitigate shortcut learning in a downstream medical classifier. Code is available at https://github.com/GSK-AI/RadCF/.

0.59

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.65
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

cs.LG eess.IVstat.ML ·2026-08-13 ·Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu +1 more
similarity 0.64
Abstract

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.

0.42

Intervention-Aware Clinical World Model for Post-Op Outcome Forecasting in Cardiology

cs.LG cs.CV ·2026-08-13 ·Yunsung Chung, Yingshuo Liu, Abboud F. Hassan, Han Feng, Mary M. Maleckar +2 more
published similarity 0.64
Abstract · Medical World Models (MWM) Workshop at MICCAI 2026

Many clinical prediction models treat post-intervention outcomes as a one-step mapping from baseline measurements to a future endpoint. However, recovery after a procedure often unfolds as an irregular trajectory: clinical observations, medication changes, repeat interventions, and physiological measurements are recorded asynchronously and can change risk assessment over time. We propose an intervention-aware clinical world model that represents each patient with a structured latent state and evolves it through time-ordered post-intervention events. The model first encodes baseline imaging into a 3D spatial latent state. It then updates this state using procedural context, static covariates, elapsed time, and peri-event physiological embeddings. Follow-up imaging provides training-only supervision through a latent forecasting objective. We apply the framework to atrial fibrillation ablation. During the 90-day recovery window, irregular post-procedure records provide clinically meaningful evidence for long-term recurrence risk. In repeated internal cross-validation on DECAAF-II, our model achieves AUROC 0.756 and AUPRC 0.777 for recurrence prediction. It also achieves a scar-extent MAE of 2.971 percentage points without requiring follow-up MRI intensities at inference. The learned state supports recurrence-risk queries at different horizons and retrospective input editing of blanking-period records.

0.46

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.63
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

Interaction-Gated Time-Frequency Learning for Parameter-Efficient PPG-Based Heart Rate Estimation

cs.LG cs.AIeess.SP ·2026-10-20 ·Anh Khoi Pham, Phat Lam, Thien Truong Nguyen Ly, Lam Pham
benchmark similarity 0.63
Abstract · Conference preprint, accepted at SoICT 2026

Photoplethysmography (PPG) enables low-cost and non-invasive heart rate (HR) monitoring but remains sensitive to waveform distortion, physiological variability, and measurement interference. Temporal waveform characteristics and frequency-domain periodicity provide complementary information for HR estimation; however, effectively exploring and integrating these representations within a compact model remains challenging. This paper proposes TF-IG, a parameter-efficient interaction-gated time-frequency learning framework for PPG-based HR estimation. TF-IG employs a dual-branch architecture in which a temporal branch captures pulse morphology via dilated depthwise-separable convolutions, while a frequency branch extracts cardiac periodicity information from bounded log-spectrogram representations. To combine the two domains, we introduce an interaction-gated fusion module that explicitly models feature agreement and discrepancy, while also learning feature-wise weights to balance temporal and spectral information. A parameter-shared regression head further maps the temporal, spectral, and fused representations into the final HR prediction space. Experiments on the benchmark BIDMC PPG and Respiration Dataset using a subject-exclusive training, validation, and test protocol show that TF-IG achieves a mean absolute error (MAE) of 1.227 BPM, a root mean square error (RMSE) of 2.060 BPM, a Pearson correlation coefficient of 0.9934, and 92.28 percent of estimates within 3 BPM, while remaining parameter-efficient with only 84.6K parameters. Ablation results further demonstrate the complementary contributions of the temporal and frequency branches, interaction-gated fusion, and shared regression head. These results indicate that explicitly modeling cross-domain interactions provides an effective accuracy-complexity trade-off for lightweight PPG-based HR estimation.

0.11