CS Paper Radar

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi, Andrew King, Oleg Aslanidi

cs.AI ·submitted 2026-11-09 12:27 UTC · v2

Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

Closest papers

Nearest neighbours by meaning across the whole index.

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.75
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.32

TransECG-SSL: Hybrid Self-Supervised Representation Learning for ECG Arrhythmia Classification

cs.LG ·2026-10-26 ·Ahtisham Ayyub, Fasih Haider, Muhammad Rehan Usman, Saturnino Luz, Christos Politis +1 more
similarity 0.74
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics

Cross-dataset generalisation remains a major challenge for automated electrocardiogram (ECG) arrhythmia classification because of differences in patient populations, acquisition protocols, annotation practices, and class distributions. Learning representations that remain informative across independent datasets could reduce reliance on dataset-specific labelled data. We propose TransECG-SSL, a self-supervised framework for transferable heartbeat representation learning from unlabelled ECG data. A Transformer encoder is pretrained using a hybrid objective combining masked signal reconstruction and contrastive learning, then frozen and evaluated by linear probing under patient-disjoint evaluation. Experiments across three public ECG databases and seven source--target settings show that Hybrid SSL consistently outperforms randomly initialised Transformers and achieves higher balanced accuracy than architecture-matched source-supervised pretraining. Reconstruction-only SSL remains competitive with Hybrid SSL, whereas contrastive-only pretraining performs substantially worse, highlighting the importance of masked reconstruction for transferability. Cross-dataset transfer nevertheless reduces balanced accuracy relative to target-specific self-supervised pretraining, while minority arrhythmia classes remain challenging under severe class imbalance. These findings demonstrate the potential of label-efficient self-supervised learning for cross-dataset ECG representation transfer while highlighting persistent limitations from domain shift and class imbalance.

0.24

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

cs.LG eess.SP ·2026-08-13 ·Ahmed Sameh, Ramzi Al-Sharawi, Yogatheesan Varatharajah
publishedcode/data similarity 0.72
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026). 6 pages, 2 figures…

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.

0.41

TRACE: Expert-Aligned ECG Representation Learning with Rigorous Benchmarking and Real-World Validation in Acute Cardiac Care

cs.LG cs.AI ·2026-09-28 ·Lovely Yeswanth Panchumarthi, Andrew Lu, Saurabh Kataria, Delgersuren Bold, Minxiao Wang +9 more
benchmark similarity 0.72
Abstract · 42 pages, 4 figures and 1 table

TRACE (Text-Reinforced Analysis of Cardio ECGs) is a multimodal electrocardiogram (ECG) representation model that learns clinically grounded signal embeddings for downstream cardiac classification. It is designed to address the limitations of existing CLIP-style training, which often struggles with noisy clinical text and fails to leverage the complementary strengths of unimodal (from ECG) and cross-modal (between ECG and matched cardiologist reports) learning. To bridge this gap, we propose a hybrid architecture that jointly learns unimodal and cross-modal representations via uncertainty-weighted multi-task learning while utilizing an LLM-based pipeline to extract high-fidelity findings from cardiologist reports. We evaluate TRACE across a spectrum of clinical urgency, establishing robust performance on public benchmarks for arrhythmia classification and structural abnormalities relative to existing unimodal and multimodal ECG models. To demonstrate real-world utility, we further validate the model on acute coronary occlusion (ACO), where the prevailing ST-elevation criteria miss 25-34% of true occlusions. Utilizing a large private ACO dataset with expert-annotated ground truth, TRACE significantly outperforms real-world clinical practice, yielding a 19.0% increase in sensitivity or a 62.6% reduction in false positive rates at the clinical baseline. This extensive evaluation confirms that TRACE delivers both strong performance on benchmark tasks and tangible clinical impact in the most acute, high-risk cardiac scenarios.

0.11

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

cs.LG eess.IVstat.ML ·2026-08-13 ·Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu +1 more
similarity 0.71
Abstract

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.

0.42

A Hybrid CNN--State-Space--Attention Backbone with Joint-Embedding Predictive Pretraining for 12-Lead ECG Classification

cs.CV ·2026-09-24 ·Yakoub Bazi, Sarah Aljuhani, Mohamad M. Al Rahhal, Mansour Zuair, Naif Alajlan
code/data similarity 0.70
Abstract

Automatic 12-lead electrocardiogram (ECG) classification requires representations that jointly capture local waveform morphology, long-range temporal dynamics, and cross-lead dependencies, yet integrating these properties within a single efficient architecture remains challenging. This paper introduces a hybrid CNN-SSM-Attention backbone for 12-lead ECG classification. A convolutional stem performs early waveform tokenization and temporal reduction, mixed state-space and depthwise-convolutional blocks model temporal dynamics and local morphology, and a late self-attention stage enables global token interaction at reduced resolution. To improve transfer from unlabeled data, we further develop an ECG-oriented Joint-Embedding Predictive Pretraining (JEPA) framework. Unlike ViT-based JEPA methods that mask patch tokens before the encoder, the proposed method samples span masks at the latent temporal resolution and projects them back to the waveform domain, then predicts clean latent targets from a momentum encoder without waveform reconstruction. Experiments on CPSC2018, Chapman-Shaoxing, and PTB-XL, with pretraining on approximately 350K unlabeled CODE-15 recordings, show that the proposed backbone provides strong supervised baselines under a compact parameter budget. JEPA pretraining further improves transfer, particularly in reduced-label settings and under both full fine-tuning and LoRA-based adaptation. Code: https://github.com/yakoubbazi/Hybrid_ECG_Jepa

0.26

Robust Transfer Learning for Paper ECG Recognition

cs.LG cs.AI ·2026-09-30 ·Yinghao Xie, Zhenbang Dai, Haojun Wang, Jinyu Cai, Fabio Bonassi +4 more
similarity 0.70
Abstract

Paper ECG recognition is challenging because real-world ECG images vary in layout, physical artifacts, and label availability. We introduce RobECG-CL, a rank-aware contrastive learning framework for robust paper ECG representation learning. Starting from standard 12-lead ECG recordings, we construct progressively degraded paper ECG views with heterogeneous layouts and train the model to balance same-recording invariance with degradation-aware ordering. Across synthetic stress tests on CODE-II and EchoNext, RobECG-CL improves robustness under severe degradation and few-shot transfer, outperforming contrastive learning baselines and surpassing the waveform-based foundation model, ECG-FM, in the 1% labeled setting. On 312 samples of hospital data with 37 labels, RobECG-CL achieves the best macro AUROC.

0.16

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

cs.LG ·2026-08-24 ·Wenhan Jiang, Zhipeng Deng, Jiale Zhou, Haolin Wang, Yafei Ou +1 more
top venue similarity 0.70
Abstract · Accepted at MICCAI 2026

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.

0.55