CS Paper Radar

A Hybrid CNN--State-Space--Attention Backbone with Joint-Embedding Predictive Pretraining for 12-Lead ECG Classification

Yakoub Bazi, Sarah Aljuhani, Mohamad M. Al Rahhal, Mansour Zuair, Naif Alajlan

cs.CV ·submitted 2026-09-24 10:58 UTC · v1
code/data

Abstract

Automatic 12-lead electrocardiogram (ECG) classification requires representations that jointly capture local waveform morphology, long-range temporal dynamics, and cross-lead dependencies, yet integrating these properties within a single efficient architecture remains challenging. This paper introduces a hybrid CNN-SSM-Attention backbone for 12-lead ECG classification. A convolutional stem performs early waveform tokenization and temporal reduction, mixed state-space and depthwise-convolutional blocks model temporal dynamics and local morphology, and a late self-attention stage enables global token interaction at reduced resolution. To improve transfer from unlabeled data, we further develop an ECG-oriented Joint-Embedding Predictive Pretraining (JEPA) framework. Unlike ViT-based JEPA methods that mask patch tokens before the encoder, the proposed method samples span masks at the latent temporal resolution and projects them back to the waveform domain, then predicts clean latent targets from a momentum encoder without waveform reconstruction. Experiments on CPSC2018, Chapman-Shaoxing, and PTB-XL, with pretraining on approximately 350K unlabeled CODE-15 recordings, show that the proposed backbone provides strong supervised baselines under a compact parameter budget. JEPA pretraining further improves transfer, particularly in reduced-label settings and under both full fine-tuning and LoRA-based adaptation. Code: https://github.com/yakoubbazi/Hybrid_ECG_Jepa

Closest papers

Nearest neighbours by meaning across the whole index.

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

cs.LG eess.SP ·2026-08-13 ·Ahmed Sameh, Ramzi Al-Sharawi, Yogatheesan Varatharajah
publishedcode/data similarity 0.74
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026). 6 pages, 2 figures…

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.

0.41

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.70
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

cs.LG eess.IVstat.ML ·2026-08-13 ·Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu +1 more
similarity 0.69
Abstract

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.

0.42

Deviation-Aware Pretraining for Cardiovascular Disease Detection from Electrocardiograms

cs.LG ·2026-11-10 ·Siyuan Yan, Haibo Zheng, Feng Lu, Wei Li
similarity 0.69
Abstract

Electrocardiogram (ECG) signals are critical for cardiovascular disease (CVD) detection. Most current deep learning models rely on supervised, task-specific training, which limits their ability to generalize across diseases, patient populations, and acquisition settings. This paper presents a self-supervised ECG feature extraction framework that learns from nearly one million unlabeled 12-lead ECG recordings. The framework includes two modules: Deviation Localization Embedding (DLE), which detects waveform-level deviations from normal patterns, and Association Reconstruction Embedding (ARE), which models cross-lead associations through deviation-guided reconstruction to capture abnormal patterns expressed across multiple leads. These modules enable the framework to capture subtle deviation-related patterns and their cross-lead context. The framework achieves up to 6.5% AUROC and 12.8% F1 improvements over prior methods on multiple public datasets, even without additional fine-tuning the pretrained feature extractor. Embedding visualizations show that the learned features support meaningful disease grouping and anomaly identification. The approach reduces the need for labeled data and can support clinicians in diverse healthcare settings. The framework has potential to improve early detection and monitoring of cardiovascular diseases, contributing to more accessible and equitable heart care.

0.20

QECGBERT: A Scalable ECG Foundation Model Based on Self-Supervised Language Learning via VQ-VAE Waveform Tokenization

cs.LG cs.AI ·2026-10-25 ·Aruna Mohan, Burcu Ozek, Or Zilbershot, Fatemeh Afghah
similarity 0.69
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

AI foundation models play a pivotal role in advancing heart disease diagnosis from electrocardiogram (ECG) data, particularly for rare diseases where the lack of sufficient labeled data hinders supervised learning. However, most self-supervised learning methods treat ECGs as generic sequence or image data without exploiting underlying physiological structure. To address this limitation, we propose QECGBERT, a self-supervised ECG language model that explicitly encodes physiological semantics by tokenizing the P, QRS, T, and isoelectric background waveforms. Vector-quantized variational autoencoder (VQ-VAE) tokenization is applied to each 12-lead ECG, with tokens enriched by continuous waveform features to preserve morphology lost during quantization without increasing sequence length. This design enables compact BERT masked language modeling with short sequences, improving scalability and reducing computational cost relative to long-sequence approaches. QECGBERT applies BERT pre-training to the MIMIC-IV dataset containing over 800,000 unlabeled ECG recordings, and fine-tuning on labeled PTB-XL, CPSC2018, and Chapman--Shaoxing--Ningbo datasets for evaluation. The results demonstrate that QECGBERT achieves comparable or superior performance to published benchmarks, offering a scalable, physiologically aware approach to ECG foundation modeling for cardiac diagnosis.

0.22

AF-Mamba: Efficient Long-Term Signal Modeling for Early Prediction of Atrial Fibrillation Onset

cs.LG ·2026-09-07 ·Yongbin Lee, Ki H. Chon
code/data similarity 0.69
Abstract · 11 pages, 5 figures, 7 tables. Extended version of IEEE BSN 2025. Code: https://github.com/yongbin98/AF_Mamba

Atrial fibrillation (AF) is the most common cardiac arrhythmia and is associated with increased risks of stroke and heart failure. The growing availability of wearable and portable ECG monitoring enables continuous assessment of cardiac rhythm outside clinical settings. Predicting AF before its onset could provide additional lead time for timely clinical assessment and potentially improve the management of patients at risk of AF-related complications. This study focuses on predicting AF onset one hour in advance using long-term RR intervals (RRIs). To address this challenge, we propose a deep learning architecture that integrates temporal convolutional networks (TCNs) for local features encoding with Mamba, a selective state-space model capable of long-range sequence modeling. This hybrid TCN-Mamba design enables efficient training and inference on one-hour input windows, overcoming limitations of Transformers' quadratic scaling and recurrent networks' vanishing gradients. In subject-wise 5-fold testing, the proposed model achieved a sensitivity of 0.889, specificity of 0.943, F1-score of 0.813, AUROC of 0.974, and AUPRC of 0.933. In paired cross-dataset holdout evaluation, AF-Mamba maintained discriminative performance across unseen AF and NSR datasets, achieving a mean AUROC of 0.897. Compared against state-of-the-art AF prediction models and general time-series models, AF-Mamba achieved competitive predictive performance while providing a favorable performance-efficiency trade-off for long RRI sequences. These findings demonstrate the potential of AF-Mamba for accurate AF prediction one hour in advance and real-time continuous ambulatory monitoring.

0.38

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

cs.LG cs.AIcs.CVeess.SP ·2026-10-06 ·Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim +4 more
benchmarkcode/data similarity 0.67
Abstract · 20 pages, 5 figures. First two authors contributed equally

Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

0.30

DR-net-Mamba: Selective State-Space Modeling for Long-Range ECG Time-Series Denoising

cs.LG cs.AI ·2026-09-28 ·Basile Morel, Samuel Ruiperez-Campillo, Andreas P. Streich, Julia E. Vogt, Thomas Hofmann
similarity 0.67
Abstract · First three authors are co-first. Last two authors are co-last

Electrocardiogram (ECG) recordings are corrupted by non-stationary noise sources that degrade diagnostic reliability, particularly in ambulatory and long-duration recordings. Deep learning denoisers exist, but convolutional architectures are limited by their receptive field, transformer-based models scale quadratically with sequence length, and diffusion-based approaches incur prohibitive inference cost. We propose a Mamba-augmented model that inserts selective state-space blocks at the convolutional bottleneck, combining local feature extraction with long-range temporal modeling at linear complexity. We comprehensively evaluate the proposed model with respect to reconstruction fidelity, noise robustness, recording-length scaling, and downstream diagnostic classification across over 40 pathology classes. On synthetic and real datasets, our model achieves the highest SNR and lowest RMSE, with the Mamba advantage increasing with sequence length and in low-SNR regimes. On classification with two independent classifiers, the proposed Mamba-based models achieve the best macro AUROC among all denoisers and improve over their convolutional base models. Calibration is more nuanced and classifier-dependent: denoising improves Binary Cross-Entropy and Brier score on Inception1D but often fails to beat the noisy input on ResNet1D-Wang, and the lead-specific Mamba variant is the only denoiser to improve both calibration metrics over the noisy baseline on both classifiers. Per-class analysis reveals a morphology-dependent benefit: Mamba substantially improves ST/T-change diagnoses, which depend on broad, context-sensitive waveforms.

0.07