CS Paper Radar

Deviation-Aware Pretraining for Cardiovascular Disease Detection from Electrocardiograms

Siyuan Yan, Haibo Zheng, Feng Lu, Wei Li

cs.LG ·submitted 2026-11-10 14:29 UTC · v1

Abstract

Electrocardiogram (ECG) signals are critical for cardiovascular disease (CVD) detection. Most current deep learning models rely on supervised, task-specific training, which limits their ability to generalize across diseases, patient populations, and acquisition settings. This paper presents a self-supervised ECG feature extraction framework that learns from nearly one million unlabeled 12-lead ECG recordings. The framework includes two modules: Deviation Localization Embedding (DLE), which detects waveform-level deviations from normal patterns, and Association Reconstruction Embedding (ARE), which models cross-lead associations through deviation-guided reconstruction to capture abnormal patterns expressed across multiple leads. These modules enable the framework to capture subtle deviation-related patterns and their cross-lead context. The framework achieves up to 6.5% AUROC and 12.8% F1 improvements over prior methods on multiple public datasets, even without additional fine-tuning the pretrained feature extractor. Embedding visualizations show that the learned features support meaningful disease grouping and anomaly identification. The approach reduces the need for labeled data and can support clinicians in diverse healthcare settings. The framework has potential to improve early detection and monitoring of cardiovascular diseases, contributing to more accessible and equitable heart care.

Closest papers

Nearest neighbours by meaning across the whole index.

Interpretable Stress Detection from ECG Signals Using Motif-Based Anomaly Analysis

eess.SP cs.LG ·2026-08-27 ·Zhanna Balyan, Sachin Kumar
similarity 0.72
Abstract

Stress detection using physiological signals has gained significant attention due to its impact on both physical and mental health. While existing approaches based on machine learning and deep learning achieve strong predictive performance, they often rely on black-box models and fail to capture individual variability in physiological responses. In this work, we propose an interpretable and personalized framework for stress detection using electrocardiogram (ECG) signals based on motif discovery and Matrix Profile analysis. Instead of training a classifier, the method learns subject-specific baseline cardiac behavior by extracting recurring heartbeat patterns (motifs) from ECG signals. Stress is then detected as a deviation from these baseline patterns using a distance-based anomaly score. Experiments are conducted on the WESAD dataset using a carefully designed train-validation-test protocol to ensure reliable evaluation. The results show that the proposed approach can effectively detect stress for several subjects while providing clear interpretability through direct comparison of ECG patterns. However, the performance varies across individuals due to differences in physiological responses, with some subjects exhibiting minimal morphological changes under stress. Additional analysis incorporating heart rate variability (HRV) features reveals that while HRV can improve performance in certain cases, its contribution is not consistent across all subjects. These findings highlight the importance of personalization and interpretability in physiological stress detection and demonstrate that motif-based approaches provide a meaningful alternative to black-box models, while also revealing inherent limitations due to inter-subject variability.

0.23

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

cs.LG cs.AIcs.CVeess.SP ·2026-10-06 ·Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim +4 more
benchmarkcode/data similarity 0.71
Abstract · 20 pages, 5 figures. First two authors contributed equally

Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

0.30

QECGBERT: A Scalable ECG Foundation Model Based on Self-Supervised Language Learning via VQ-VAE Waveform Tokenization

cs.LG cs.AI ·2026-10-25 ·Aruna Mohan, Burcu Ozek, Or Zilbershot, Fatemeh Afghah
similarity 0.70
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

AI foundation models play a pivotal role in advancing heart disease diagnosis from electrocardiogram (ECG) data, particularly for rare diseases where the lack of sufficient labeled data hinders supervised learning. However, most self-supervised learning methods treat ECGs as generic sequence or image data without exploiting underlying physiological structure. To address this limitation, we propose QECGBERT, a self-supervised ECG language model that explicitly encodes physiological semantics by tokenizing the P, QRS, T, and isoelectric background waveforms. Vector-quantized variational autoencoder (VQ-VAE) tokenization is applied to each 12-lead ECG, with tokens enriched by continuous waveform features to preserve morphology lost during quantization without increasing sequence length. This design enables compact BERT masked language modeling with short sequences, improving scalability and reducing computational cost relative to long-sequence approaches. QECGBERT applies BERT pre-training to the MIMIC-IV dataset containing over 800,000 unlabeled ECG recordings, and fine-tuning on labeled PTB-XL, CPSC2018, and Chapman--Shaoxing--Ningbo datasets for evaluation. The results demonstrate that QECGBERT achieves comparable or superior performance to published benchmarks, offering a scalable, physiologically aware approach to ECG foundation modeling for cardiac diagnosis.

0.22

Graph-Based Pseudo-multimodal Contrastive Learning for 12-Lead ECG Representations

cs.LG ·2026-08-27 ·Mengyu Wang, Kozo Okada, Takafumi Goto, Natsuko Jinba, Hiroki Yamaya +2 more
published similarity 0.69
Abstract · 7 pages, 7 figures. Presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026…

12-lead electrocardiogram (ECG) is a standard, non-invasive examination widely used for diagnosing coronary artery disease, where clinical interpretation relies on comparing waveform patterns across multiple leads. However, most existing ECG analysis methods focus on single-lead signals or treat each lead independently, and typically process ECG signals as one-dimensional time-series data using CNNs or RNNs. While effective in modeling local waveform changes, such approaches have difficulty capturing inter-lead dependency and global waveform patterns essential for clinical diagnosis. To address this limitation, we propose a graph-based pseudo-multimodal contrastive learning framework called Graph-CMMC. ECG waveforms are transformed into Gramian Angular Difference Field (GADF) images to construct complementary representations of the same cardiac activity, enabling a pseudo-multimodal learning setting. Using all 12 leads, Graph-CMMC aligns waveform and GADF representations in a self-supervised manner, while a graph-based relational module is employed to model inter-lead dependency and enforce structural consistency across leads during contrastive learning. Experimental results on a multi-label coronary artery occlusion classification task demonstrate that the proposed framework achieves competitive performance compared to supervised learning methods. These results further suggest the effectiveness of using GADF as a complementary representation and incorporating explicit graph-based modeling of inter-lead dependency for learning robust 12-lead ECG representations.

0.32

Atrial Fibrillation Detection with Arbitrary Leads via a Codebook-Based Reconstruction-Classification Framework

cs.LG q-bio.QM ·2026-08-19 ·Hongtao Li, Jia Wei, Guoyao Li, Yuchen Lei, Guangnian Ma +4 more
benchmark similarity 0.69
Abstract

\textbf{Background and Objective}: Reliable atrial fibrillation (AF) detection from electrocardiogram (ECG) signals remains challenging in real-world clinical settings due to variable lead configurations, cross-dataset domain shifts, and pervasive physiological and technical artifacts. So we develop a robust and generalizable deep learning model for accurate AF detection.\\ \textbf{Methods}: We propose the Dual-Codebook Graph Collaborative Network (DCGCNet), a novel end-to-end vector-quantized variational autoencoder that jointly performs AF classification and ECG reconstruction. DCGCNet introduces two key components: (1) a Local-Global Contrastive Module for learning noise-invariant representations, and (2) an Adaptive Codebook Vector Quantizer that dynamically refines codebook prototypes to better align with input data distributions, thereby preventing codebook collapse and enhancing generalization.\\ \textbf{Results}: DCGCNet achieves state-of-the-art performance in standard intra-dataset 12-lead evaluation and demonstrates exceptional cross-dataset generalization across seven diverse settings, consistently attaining AUC > 0.98 in all cases. Furthermore, it maintains high diagnostic accuracy under realistic noisy conditions, including baseline wander, powerline interference, and EMG artifacts.\\ \textbf{Conclusions}: DCGCNet establishes a new benchmark for robust, generalizable, and noise-resilient AF detection, showing strong potential for deployment in real-world clinical environments.

0.15

A Hybrid CNN--State-Space--Attention Backbone with Joint-Embedding Predictive Pretraining for 12-Lead ECG Classification

cs.CV ·2026-09-24 ·Yakoub Bazi, Sarah Aljuhani, Mohamad M. Al Rahhal, Mansour Zuair, Naif Alajlan
code/data similarity 0.69
Abstract

Automatic 12-lead electrocardiogram (ECG) classification requires representations that jointly capture local waveform morphology, long-range temporal dynamics, and cross-lead dependencies, yet integrating these properties within a single efficient architecture remains challenging. This paper introduces a hybrid CNN-SSM-Attention backbone for 12-lead ECG classification. A convolutional stem performs early waveform tokenization and temporal reduction, mixed state-space and depthwise-convolutional blocks model temporal dynamics and local morphology, and a late self-attention stage enables global token interaction at reduced resolution. To improve transfer from unlabeled data, we further develop an ECG-oriented Joint-Embedding Predictive Pretraining (JEPA) framework. Unlike ViT-based JEPA methods that mask patch tokens before the encoder, the proposed method samples span masks at the latent temporal resolution and projects them back to the waveform domain, then predicts clean latent targets from a momentum encoder without waveform reconstruction. Experiments on CPSC2018, Chapman-Shaoxing, and PTB-XL, with pretraining on approximately 350K unlabeled CODE-15 recordings, show that the proposed backbone provides strong supervised baselines under a compact parameter budget. JEPA pretraining further improves transfer, particularly in reduced-label settings and under both full fine-tuning and LoRA-based adaptation. Code: https://github.com/yakoubbazi/Hybrid_ECG_Jepa

0.26

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

cs.LG eess.SP ·2026-08-13 ·Ahmed Sameh, Ramzi Al-Sharawi, Yogatheesan Varatharajah
publishedcode/data similarity 0.69
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026). 6 pages, 2 figures…

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.

0.41

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

cs.LG ·2026-08-24 ·Wenhan Jiang, Zhipeng Deng, Jiale Zhou, Haolin Wang, Yafei Ou +1 more
top venue similarity 0.68
Abstract · Accepted at MICCAI 2026

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.

0.55