CS Paper Radar

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim, Young Ho Lee, Yu Jeong Kim, Sunghoon Joo, Ki Hong Lee

cs.LG cs.AIcs.CVeess.SP ·submitted 2026-10-06 07:32 UTC · v1
benchmarkcode/data

Abstract

Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

Comment
20 pages, 5 figures. First two authors contributed equally

Closest papers

Nearest neighbours by meaning across the whole index.

Bridging the Gap in ECG-Based Emotion Recognition: A Unified Evaluation of Deep Learning Models

eess.SP cs.LG ·2026-09-14 ·Timothy C Sweeney-Fanelli, Ajan Ahmed, Masudul Imtiaz
publishedbenchmarkcode/data similarity 0.72
Abstract · Accepted at 2026 IEEE 17th Annual Ubiquitous Computing, Electronics & Mobile Communication Conference (UEMCON) - 2026 IEEE UEMCON

Deep learning has led to numerous proposed architectures for Automated Emotion Recognition (AER) from electrocardiogram (ECG) data, but inconsistencies in preprocessing, training, and evaluation make direct comparisons difficult. Most studies train and validate models on individual datasets collected under homogeneous conditions, limiting variability and raising concerns about generalizability. Cross-dataset validation is sometimes used but primarily assesses model adaptability rather than true generalization. This study presents a comparative analysis of prominent deep learning architectures in AER, emphasizing model generalization over dataset adaptability. To enable this benchmark, we introduce two open-source frameworks: Affective Research on Representations and Classifications (ARRC), a standardized benchmarking toolkit, and Affective Research Dataset Toolkit (ARDT), a framework for inter-dataset training and validation. Using ARDT, we consolidate three publicly available AER datasets, CUADS, ASCERTAIN, and DREAMER, into a single dataset, increasing variability in sensor types, recording conditions, and participant demographics. We then use ARRC to evaluate three widely studied deep learning models and two CNN baselines through hyperparameter optimization and 10-fold cross-validation. Our findings provide insights into the trade-offs between classification accuracy and model complexity, establishing a reproducible benchmark for AER research. All source code for ARRC, ARDT, and model evaluation is publicly available to ensure transparency and facilitate further research.

0.37

Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU

cs.LG eess.SP ·2026-09-08 ·Athanasios Papastathopoulos-Katsaros, Alexandra Stavrianidi, Zhandong Liu
publishedbenchmark similarity 0.71
Abstract · Published at CinC 2026

False ventricular tachycardia (VT) alarms are a leading contributor to alarm fatigue in intensive care units. We propose a deep learning framework combining a 1D SE-ResNet with ICU-realistic data augmentations and a physics-informed auxiliary reconstruction task based on the three-element Windkessel hemodynamic model, implemented as a differentiable forward simulation. By requiring the network's latent representation to produce physiologically plausible arterial pressure waveforms, artifact-driven ECG patterns are penalized while true VT remains coherent across modalities. Evaluated on the VTaC benchmark under a strict real-time protocol (10-second pre-alarm window), our method achieves a 5-point Challenge Score improvement over prior state-of-the-art. Ablation studies confirm that the physics-informed objective is the primary performance driver, providing gains in accuracy, 2x label efficiency, and more localized and clinically meaningful ECG segments.

0.39

TransECG-SSL: Hybrid Self-Supervised Representation Learning for ECG Arrhythmia Classification

cs.LG ·2026-10-26 ·Ahtisham Ayyub, Fasih Haider, Muhammad Rehan Usman, Saturnino Luz, Christos Politis +1 more
similarity 0.71
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics

Cross-dataset generalisation remains a major challenge for automated electrocardiogram (ECG) arrhythmia classification because of differences in patient populations, acquisition protocols, annotation practices, and class distributions. Learning representations that remain informative across independent datasets could reduce reliance on dataset-specific labelled data. We propose TransECG-SSL, a self-supervised framework for transferable heartbeat representation learning from unlabelled ECG data. A Transformer encoder is pretrained using a hybrid objective combining masked signal reconstruction and contrastive learning, then frozen and evaluated by linear probing under patient-disjoint evaluation. Experiments across three public ECG databases and seven source--target settings show that Hybrid SSL consistently outperforms randomly initialised Transformers and achieves higher balanced accuracy than architecture-matched source-supervised pretraining. Reconstruction-only SSL remains competitive with Hybrid SSL, whereas contrastive-only pretraining performs substantially worse, highlighting the importance of masked reconstruction for transferability. Cross-dataset transfer nevertheless reduces balanced accuracy relative to target-specific self-supervised pretraining, while minority arrhythmia classes remain challenging under severe class imbalance. These findings demonstrate the potential of label-efficient self-supervised learning for cross-dataset ECG representation transfer while highlighting persistent limitations from domain shift and class imbalance.

0.24

Deviation-Aware Pretraining for Cardiovascular Disease Detection from Electrocardiograms

cs.LG ·2026-11-10 ·Siyuan Yan, Haibo Zheng, Feng Lu, Wei Li
similarity 0.71
Abstract

Electrocardiogram (ECG) signals are critical for cardiovascular disease (CVD) detection. Most current deep learning models rely on supervised, task-specific training, which limits their ability to generalize across diseases, patient populations, and acquisition settings. This paper presents a self-supervised ECG feature extraction framework that learns from nearly one million unlabeled 12-lead ECG recordings. The framework includes two modules: Deviation Localization Embedding (DLE), which detects waveform-level deviations from normal patterns, and Association Reconstruction Embedding (ARE), which models cross-lead associations through deviation-guided reconstruction to capture abnormal patterns expressed across multiple leads. These modules enable the framework to capture subtle deviation-related patterns and their cross-lead context. The framework achieves up to 6.5% AUROC and 12.8% F1 improvements over prior methods on multiple public datasets, even without additional fine-tuning the pretrained feature extractor. Embedding visualizations show that the learned features support meaningful disease grouping and anomaly identification. The approach reduces the need for labeled data and can support clinicians in diverse healthcare settings. The framework has potential to improve early detection and monitoring of cardiovascular diseases, contributing to more accessible and equitable heart care.

0.25

Deep learning for non-transvenous ICD screening: tailored neural network architectures, extended experiments, and explainability

cs.LG ·2026-10-27 ·Bartosz Morawski, Samuel J. Ward, Alex Touze, Lin-Thiri Toon, Paul R. Roberts +2 more
benchmarkhot direction similarity 0.69
Abstract

This paper studies two non-transvenous implantable cardioverter-defibrillators (ICDs), namely the Subcutaneous ICD (S-ICD) and the Extravascular ICD (EV-ICD). Both avoid the complications of transvenous leads but are prone to oversensing, which can trigger inappropriate shocks associated with increased mortality. Oversensing risk is predicted by the ratio of T- or P-wave amplitude to R-wave amplitude (T:R, P:R), and these ratios vary over a 24-hour period. Yet S-ICD screening uses a single 10-second electrocardiogram (ECG) segment, and the EV-ICD has no formal screening protocol whatsoever. We present a 24-hour ambulatory screening framework for both devices which includes the first T:R analysis in an EV-ICD cohort and the first full evaluation of P:R prediction. We introduce AmpRatioNet, a family of 1D convolutional neural network architectures operating directly on the ECG signal, and benchmark it against the best existing approach - based on 2D phase space reconstruction images. Evaluation uses 4,605 clinician-annotated 10-second segments from 89 patients, with patient-level 10-fold cross-validation and bootstrap confidence intervals. AmpRatioNet-SE demonstrates superior performance on every metric in each setting with no device- or ratio-specific redesign. An explainability analysis against interpretable classical peak labelling algorithms shows that AmpRatioNet-SE's increase in error on oversensing-prone segments is up to 14 times smaller than theirs. Segment-level predictions are aggregated into a 24-hour timeline, extending S-ICD screening beyond 10 seconds and offering a plausible EV-ICD screening pathway pending device-level validation.

0.26

Decoder Design Matters for ECG Delineation

cs.LG cs.AI ·2026-09-15 ·Joseph Scharpf, William Han, Chaojing Duan, Michael A. Rosenberg, Emerson Liu +1 more
code/datahot direction similarity 0.69
Abstract · 5 pages, 3 figures

Electrocardiogram (ECG) delineation identifies the boundaries of P waves, QRS complexes, and T waves, providing structural annotations that can guide AI models in learning to interpret ECGs. However, training accurate delineation models requires manual annotations that are scarce and time-consuming to obtain. Recent work addresses this limitation through semi-supervised learning (SSL), but the design of the architecture, particularly the decoder, has received less attention. To this end, we propose R-U-Net, an ECG delineation model that pairs a ResNet-18 encoder with a U-Net decoder. On SemiSegECG, R-U-Net outperforms the strongest evaluated ResNet-18 + fully convolutional network (FCN) head baseline in each of the 16 in-domain settings by 3.3-13.0 mIoU and achieves 82.6 mIoU in the cross-domain setting, an improvement of 8.1 mIoU. Controlled ablations show that decoder design contributes more to performance gains than the evaluated SSL methods, motivating further exploration of architectures for ECG delineation. All code is open-source at github.com/ELM-Research/ECG-Delineation.

0.47

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.69
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.20

Towards Myocardial Infarction Diagnosis: An Investigation into Machine Learning and Deep Learning Algorithms using ECG Data

eess.IV cs.CVcs.LG ·2026-10-26 ·Rafid Ahnaf, Husne Mubarak, Fahim Ahsan, G. M. Refatul Islam, Rafeed Rahman +1 more
similarity 0.69
Abstract · 18 pages, 7 figures, 3 tables. Based on the authors' undergraduate thesis at BRAC University (2023)

Myocardial Infarction (MI) is a severe and potentially fatal cardiac condition caused by myocardial injury due to ischemia, and timely detection can substantially reduce its mortality. Electrocardiography (ECG) is the primary diagnostic modality for MI, but manual interpretation is susceptible to human error. In this work, we propose Visionary V2, a multi-step, adaptive filtration method for ECG signal normalization, and use it to study machine learning (ML) and deep learning (DL) approaches to MI detection on the PTB Diagnostic ECG Database using all 15 available leads. On statistical features extracted from the filtered signals, such as the R-R interval, a Bagging ensemble of decision trees reaches 96.6% accuracy, compared with 87.7% when the signals are processed with BioSPPy. We further generate an image dataset from the filtered signals, on which a custom ResNet-50 misclassifies only 1 of 7,000 validation images and a custom CNN reaches an F1 score of about 98.7%. Finally, we apply LIME, Grad-CAM and Integrated Gradients to verify that the image models attend to the ECG waveform rather than the background. These results indicate that careful signal normalization combined with ML and DL models can support fast and accurate automated MI screening.

0.28