CS Paper Radar

AF-Mamba: Efficient Long-Term Signal Modeling for Early Prediction of Atrial Fibrillation Onset

Yongbin Lee, Ki H. Chon

cs.LG ·submitted 2026-09-07 03:19 UTC · v1
code/data

Abstract

Atrial fibrillation (AF) is the most common cardiac arrhythmia and is associated with increased risks of stroke and heart failure. The growing availability of wearable and portable ECG monitoring enables continuous assessment of cardiac rhythm outside clinical settings. Predicting AF before its onset could provide additional lead time for timely clinical assessment and potentially improve the management of patients at risk of AF-related complications. This study focuses on predicting AF onset one hour in advance using long-term RR intervals (RRIs). To address this challenge, we propose a deep learning architecture that integrates temporal convolutional networks (TCNs) for local features encoding with Mamba, a selective state-space model capable of long-range sequence modeling. This hybrid TCN-Mamba design enables efficient training and inference on one-hour input windows, overcoming limitations of Transformers' quadratic scaling and recurrent networks' vanishing gradients. In subject-wise 5-fold testing, the proposed model achieved a sensitivity of 0.889, specificity of 0.943, F1-score of 0.813, AUROC of 0.974, and AUPRC of 0.933. In paired cross-dataset holdout evaluation, AF-Mamba maintained discriminative performance across unseen AF and NSR datasets, achieving a mean AUROC of 0.897. Compared against state-of-the-art AF prediction models and general time-series models, AF-Mamba achieved competitive predictive performance while providing a favorable performance-efficiency trade-off for long RRI sequences. These findings demonstrate the potential of AF-Mamba for accurate AF prediction one hour in advance and real-time continuous ambulatory monitoring.

Comment
11 pages, 5 figures, 7 tables. Extended version of IEEE BSN 2025. Code: https://github.com/yongbin98/AF_Mamba

Closest papers

Nearest neighbours by meaning across the whole index.

DR-net-Mamba: Selective State-Space Modeling for Long-Range ECG Time-Series Denoising

cs.LG cs.AI ·2026-09-28 ·Basile Morel, Samuel Ruiperez-Campillo, Andreas P. Streich, Julia E. Vogt, Thomas Hofmann
similarity 0.75
Abstract · First three authors are co-first. Last two authors are co-last

Electrocardiogram (ECG) recordings are corrupted by non-stationary noise sources that degrade diagnostic reliability, particularly in ambulatory and long-duration recordings. Deep learning denoisers exist, but convolutional architectures are limited by their receptive field, transformer-based models scale quadratically with sequence length, and diffusion-based approaches incur prohibitive inference cost. We propose a Mamba-augmented model that inserts selective state-space blocks at the convolutional bottleneck, combining local feature extraction with long-range temporal modeling at linear complexity. We comprehensively evaluate the proposed model with respect to reconstruction fidelity, noise robustness, recording-length scaling, and downstream diagnostic classification across over 40 pathology classes. On synthetic and real datasets, our model achieves the highest SNR and lowest RMSE, with the Mamba advantage increasing with sequence length and in low-SNR regimes. On classification with two independent classifiers, the proposed Mamba-based models achieve the best macro AUROC among all denoisers and improve over their convolutional base models. Calibration is more nuanced and classifier-dependent: denoising improves Binary Cross-Entropy and Brier score on Inception1D but often fails to beat the noisy input on ResNet1D-Wang, and the lead-specific Mamba variant is the only denoiser to improve both calibration metrics over the noisy baseline on both classifiers. Per-class analysis reveals a morphology-dependent benefit: Mamba substantially improves ST/T-change diagnoses, which depend on broad, context-sensitive waveforms.

0.07

TSPFN: A Temporal Tabular Foundation Model for Physiological Time Series Classification

cs.LG cs.CV ·2026-08-31 ·Jérémie Stym-Popper, Clément Rambour, Federica Granese, Nicolas Thome, Olivier Bernard
publishedcode/data similarity 0.74
Abstract · Accepted at STACOM 2026 (MICCAI Workshop). 10 pages, 3 figures

Designing models that generalize effectively in low- to medium-data regimes remains a primary challenge in medical machine learning, particularly for physiological time-series classification. While tabular foundation models such as TabPFN offer an attractive alternative to conventional fine-tuning through in-context learning, they are not designed to capture the temporal dependencies inherent to physiological signals. ~In this paper, we introduce TSPFN, a foundation model that redesigns TabPFN's architecture for time series data. TSPFN integrates structured temporal representations and positional embeddings to capture intra-sample temporal and channel dependencies. To fully leverage its spatio-temporal design, the model is pretrained on 140,000 real-world physiological time series across multiple medical domains. This yields a unified, generalizable framework capable of learning the specificities of medical time series. Experiments across diverse physiological benchmarks demonstrate that TSPFN consistently outperforms standard tabular baselines and TabPFN, and achieves superior cross-domain generalization compared to specialized deep time-series models. All our experiments, ablation studies, and pre-processing scheme are publicly available at https://github.com/Jeremstym/TSPFN

0.48

Atrial Fibrillation Detection with Arbitrary Leads via a Codebook-Based Reconstruction-Classification Framework

cs.LG q-bio.QM ·2026-08-19 ·Hongtao Li, Jia Wei, Guoyao Li, Yuchen Lei, Guangnian Ma +4 more
benchmark similarity 0.70
Abstract

\textbf{Background and Objective}: Reliable atrial fibrillation (AF) detection from electrocardiogram (ECG) signals remains challenging in real-world clinical settings due to variable lead configurations, cross-dataset domain shifts, and pervasive physiological and technical artifacts. So we develop a robust and generalizable deep learning model for accurate AF detection.\\ \textbf{Methods}: We propose the Dual-Codebook Graph Collaborative Network (DCGCNet), a novel end-to-end vector-quantized variational autoencoder that jointly performs AF classification and ECG reconstruction. DCGCNet introduces two key components: (1) a Local-Global Contrastive Module for learning noise-invariant representations, and (2) an Adaptive Codebook Vector Quantizer that dynamically refines codebook prototypes to better align with input data distributions, thereby preventing codebook collapse and enhancing generalization.\\ \textbf{Results}: DCGCNet achieves state-of-the-art performance in standard intra-dataset 12-lead evaluation and demonstrates exceptional cross-dataset generalization across seven diverse settings, consistently attaining AUC > 0.98 in all cases. Furthermore, it maintains high diagnostic accuracy under realistic noisy conditions, including baseline wander, powerline interference, and EMG artifacts.\\ \textbf{Conclusions}: DCGCNet establishes a new benchmark for robust, generalizable, and noise-resilient AF detection, showing strong potential for deployment in real-world clinical environments.

0.15

Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU

cs.LG eess.SP ·2026-09-08 ·Athanasios Papastathopoulos-Katsaros, Alexandra Stavrianidi, Zhandong Liu
publishedbenchmark similarity 0.69
Abstract · Published at CinC 2026

False ventricular tachycardia (VT) alarms are a leading contributor to alarm fatigue in intensive care units. We propose a deep learning framework combining a 1D SE-ResNet with ICU-realistic data augmentations and a physics-informed auxiliary reconstruction task based on the three-element Windkessel hemodynamic model, implemented as a differentiable forward simulation. By requiring the network's latent representation to produce physiologically plausible arterial pressure waveforms, artifact-driven ECG patterns are penalized while true VT remains coherent across modalities. Evaluated on the VTaC benchmark under a strict real-time protocol (10-second pre-alarm window), our method achieves a 5-point Challenge Score improvement over prior state-of-the-art. Ablation studies confirm that the physics-informed objective is the primary performance driver, providing gains in accuracy, 2x label efficiency, and more localized and clinically meaningful ECG segments.

0.39

A Hybrid CNN--State-Space--Attention Backbone with Joint-Embedding Predictive Pretraining for 12-Lead ECG Classification

cs.CV ·2026-09-24 ·Yakoub Bazi, Sarah Aljuhani, Mohamad M. Al Rahhal, Mansour Zuair, Naif Alajlan
code/data similarity 0.69
Abstract

Automatic 12-lead electrocardiogram (ECG) classification requires representations that jointly capture local waveform morphology, long-range temporal dynamics, and cross-lead dependencies, yet integrating these properties within a single efficient architecture remains challenging. This paper introduces a hybrid CNN-SSM-Attention backbone for 12-lead ECG classification. A convolutional stem performs early waveform tokenization and temporal reduction, mixed state-space and depthwise-convolutional blocks model temporal dynamics and local morphology, and a late self-attention stage enables global token interaction at reduced resolution. To improve transfer from unlabeled data, we further develop an ECG-oriented Joint-Embedding Predictive Pretraining (JEPA) framework. Unlike ViT-based JEPA methods that mask patch tokens before the encoder, the proposed method samples span masks at the latent temporal resolution and projects them back to the waveform domain, then predicts clean latent targets from a momentum encoder without waveform reconstruction. Experiments on CPSC2018, Chapman-Shaoxing, and PTB-XL, with pretraining on approximately 350K unlabeled CODE-15 recordings, show that the proposed backbone provides strong supervised baselines under a compact parameter budget. JEPA pretraining further improves transfer, particularly in reduced-label settings and under both full fine-tuning and LoRA-based adaptation. Code: https://github.com/yakoubbazi/Hybrid_ECG_Jepa

0.26

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.68
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

A New AFIB Detection Method with Deep Neural Networks

cs.LG ·2026-10-29 ·Sara Gjorgjieva, Ana Angjelevska, Dimitar Trajanov, Marjan Gusev
benchmarkhot direction similarity 0.68
Abstract · 10 pages, 7 tables, 3 formulas

Early detection of atrial fibrillation (AFIB), characterized by irregular heart rhythms, can potentially save thousands of lives annually [20]. Numerous studies have attempted to address this challenge using various algorithms and methodologies. This paper introduces a novel and robust method that enhances the precision of AFIB detection. Neural Networks (NN) are widely recognized for their ability to identify complex electrocardiogram (ECG) patterns, facilitating the accurate detection of irregular heart rhythms. This study explores multiple conventional machine learning algorithms alongside neural network approaches to develop a robust AFIB detection system. To evaluate the effective- ness and robustness of the proposed method, the MIT BIH arrhythmia database (MITDB) and the Long-term Atrial Fibrillation Database (LTAFDB), both available on the Physionet site. Our approach presents a novel feature engineering technique, employing specific features such as a time series of the differences in successive heart rates (dBPM) rather than traditional inter-beat intervals. The model analyzes inputs labeled into five distinct classes, using only clean intervals identified through a new labeling method for training while treating others as outliers. This strategy ensures a more accurate and reliable AFIB detection process. The best-performing model, a Deep Neural Network (DNN), achieved an F1 score of 95.18% for binary atrial fibrillation classification on a benchmark dataset distinct from the training set. Models trained using our approach have demonstrated superior performance than previously published models.

0.47

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.67
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.41