CS Paper Radar

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu, Aaqib Saeed

cs.LG eess.IVstat.ML ·submitted 2026-08-13 08:21 UTC · v2

Abstract

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.

Closest papers

Nearest neighbours by meaning across the whole index.

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.71
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.21

Interaction-Gated Time-Frequency Learning for Parameter-Efficient PPG-Based Heart Rate Estimation

cs.LG cs.AIeess.SP ·2026-10-20 ·Anh Khoi Pham, Phat Lam, Thien Truong Nguyen Ly, Lam Pham
benchmark similarity 0.70
Abstract · Conference preprint, accepted at SoICT 2026

Photoplethysmography (PPG) enables low-cost and non-invasive heart rate (HR) monitoring but remains sensitive to waveform distortion, physiological variability, and measurement interference. Temporal waveform characteristics and frequency-domain periodicity provide complementary information for HR estimation; however, effectively exploring and integrating these representations within a compact model remains challenging. This paper proposes TF-IG, a parameter-efficient interaction-gated time-frequency learning framework for PPG-based HR estimation. TF-IG employs a dual-branch architecture in which a temporal branch captures pulse morphology via dilated depthwise-separable convolutions, while a frequency branch extracts cardiac periodicity information from bounded log-spectrogram representations. To combine the two domains, we introduce an interaction-gated fusion module that explicitly models feature agreement and discrepancy, while also learning feature-wise weights to balance temporal and spectral information. A parameter-shared regression head further maps the temporal, spectral, and fused representations into the final HR prediction space. Experiments on the benchmark BIDMC PPG and Respiration Dataset using a subject-exclusive training, validation, and test protocol show that TF-IG achieves a mean absolute error (MAE) of 1.227 BPM, a root mean square error (RMSE) of 2.060 BPM, a Pearson correlation coefficient of 0.9934, and 92.28 percent of estimates within 3 BPM, while remaining parameter-efficient with only 84.6K parameters. Ablation results further demonstrate the complementary contributions of the temporal and frequency branches, interaction-gated fusion, and shared regression head. These results indicate that explicitly modeling cross-domain interactions provides an effective accuracy-complexity trade-off for lightweight PPG-based HR estimation.

0.11

A Hybrid CNN--State-Space--Attention Backbone with Joint-Embedding Predictive Pretraining for 12-Lead ECG Classification

cs.CV ·2026-09-24 ·Yakoub Bazi, Sarah Aljuhani, Mohamad M. Al Rahhal, Mansour Zuair, Naif Alajlan
code/data similarity 0.69
Abstract

Automatic 12-lead electrocardiogram (ECG) classification requires representations that jointly capture local waveform morphology, long-range temporal dynamics, and cross-lead dependencies, yet integrating these properties within a single efficient architecture remains challenging. This paper introduces a hybrid CNN-SSM-Attention backbone for 12-lead ECG classification. A convolutional stem performs early waveform tokenization and temporal reduction, mixed state-space and depthwise-convolutional blocks model temporal dynamics and local morphology, and a late self-attention stage enables global token interaction at reduced resolution. To improve transfer from unlabeled data, we further develop an ECG-oriented Joint-Embedding Predictive Pretraining (JEPA) framework. Unlike ViT-based JEPA methods that mask patch tokens before the encoder, the proposed method samples span masks at the latent temporal resolution and projects them back to the waveform domain, then predicts clean latent targets from a momentum encoder without waveform reconstruction. Experiments on CPSC2018, Chapman-Shaoxing, and PTB-XL, with pretraining on approximately 350K unlabeled CODE-15 recordings, show that the proposed backbone provides strong supervised baselines under a compact parameter budget. JEPA pretraining further improves transfer, particularly in reduced-label settings and under both full fine-tuning and LoRA-based adaptation. Code: https://github.com/yakoubbazi/Hybrid_ECG_Jepa

0.26

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

cs.LG eess.SP ·2026-08-13 ·Ahmed Sameh, Ramzi Al-Sharawi, Yogatheesan Varatharajah
publishedcode/data similarity 0.69
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026). 6 pages, 2 figures…

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.

0.41

Phenomenon-Graph JEPA: Label-Efficient Representation Learning for Contactless Cardiorespiratory Sensing

cs.LG cs.ET ·2026-09-26 ·Constantino Álvarez Casado, Nhi Nguyen, Mohammad Rakibur Rahman, Le Nguyen, Manuel Lage Cañellas +2 more
similarity 0.69
Abstract · 9 pages, 4 figures, 7 tables, 24 numbered equations. Extended version of a conference submission, with additional methodological details, im…

Millimeter-wave (mmWave) radar and RGB-D cameras can record cardiac and respiratory waveforms continuously and without contact, but labeled recordings remain scarce because every label requires a supervised acquisition session. Self-supervised pretraining can exploit the unlabeled signals, yet contrastive methods depend on signal transformations and negative pairs whose validity is uncertain for cardiorespiratory data, where time warping changes breathing rate and distant windows can share the same physiological state. We present Phenomenon-Graph JEPA, a joint-embedding predictive architecture that learns from four processed one-dimensional streams without negative pairs or synthetic augmentation in its base configuration. Each stream is encoded by a temporal convolutional branch and a band-limited spectral branch. During pretraining, the model predicts stopped target embeddings along typed edges, which connect streams assigned to the same physiological phenomenon, and forward in time within a state episode. We treat this physiological typing as a testable hypothesis and compare it with wrong-edge and all-pairs prediction graphs. In the OMuSense-23 dataset, pretraining improves label-efficiency area over matched supervised training by 3.91 percentage points (95% interval 2.08 to 5.80, Holm-adjusted p = 0.006), and by 3.74 points under a second configuration evaluated on the same test participants. However, the wrong-edge and all-pairs controls do not establish a benefit from physiological typing. Optional Takens-inspired delay coordinates improve a validation comparison with learned history, whereas two wrist-only WESAD protocols do not establish a pretraining advantage. The study therefore separates the measured benefit of predictive representations from the physiological prior used to organize their training.

0.20

Reading the Whole Heart: Latent-Attention Masked Autoencoders for Multimodal Cardiac Representation Learning

cs.AI ·2026-09-10 ·Andrea Agostini, Simon Böhi, Moritz Vandenhirtz, Samuel Ruiperez-Campillo, Max Krähenmann +5 more
similarity 0.68
Abstract

Cardiovascular diagnosis and treatment rest on integrating complementary modalities, such as electrocardiogram, echocardiography, and chest X-rays, each capturing distinct but complementary aspects of cardiac pathophysiology. Yet most medical foundation models remain modality-specific, combining modalities only for finetuning or post-training. This discards the cross-modal evidence clinicians naturally integrate and ignores the structure within each modality. We introduce Latent-Attention Masked Autoencoder (LAMAE), a multimodal, structure-aware masked autoencoder that jointly learns patient-level representations during self-supervised pretraining. Instead of fusing modalities post hoc, LAMAE exchanges information directly in the latent space through a shared latent-attention module operating over a study-view-entity hierarchy, enabling aggregation of variable observations and handling of missing modalities. Pretrained on over 500'000 MIMIC-IV hospital stays, LAMAE outperforms modality-specific pretraining and strong contrastive and vision-language baselines across multimodal hospital-stay tasks, such as in-hospital mortality, ICD-10 and DRG coding, and length of stay, while remaining competitive on unimodal tasks. Modeling this structure also pays off within a single modality: even without cross-modal information, the latent-attention module improves representations over modality-specific pretraining.

0.11

SOTER: A Generative Time-Series Foundation Model for Wearable Human Physiological Signals

cs.LG cs.AI ·2026-09-15 ·Fangke Chen, Sirry Chen, Wei Chen, Zhongyu Wei
similarity 0.67
Abstract

Time-series foundation models have demonstrated strong cross-domain transfer, yet their common architectural assumptions remain poorly aligned with wearable physiological signals, which are multichannel, irregularly sampled, noisy, and governed by coupled continuous-time dynamics spanning distinct spectral scales. We present SOTER, a generative foundation model for wearable physiological time series that unifies cross-channel coupling, spectrum-guided expert specialization, and continuous-time latent evolution within a single pre-training framework. SOTER combines a spatial feature-aware backbone that models inter-signal dependencies, a power spectral density (PSD)-guided mixture-of-experts layer that routes representations to experts associated with fixed spectral bands through an inspectable, non-learned rule, and a neural controlled differential equation decoder that supports prediction and imputation at arbitrary timestamps. We pre-train SOTER on 226 billion time points from five public physiological datasets and evaluate the same pre-trained model across out-of-distribution zero-shot forecasting, frozen-encoder linear-probe classification, and continuous-time imputation on wearable benchmarks. SOTER achieves the best RMSE on 4 of 6 datasets and the best MAE on 5 of 6 in zero-shot forecasting, the highest average Macro-AUROC in classification, and the lowest imputation error on all six datasets at 75% missingness. It further remains robust to additive acquisition noise, matching or surpassing baselines evaluated on clean inputs even under the strongest corruption. These results indicate that domain-specialized foundation models for wearable physiology benefit from jointly modeling channel structure, spectral scale, and continuous-time dynamics.

0.46

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.67
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25