CS Paper Radar

Reading the Whole Heart: Latent-Attention Masked Autoencoders for Multimodal Cardiac Representation Learning

Andrea Agostini, Simon Böhi, Moritz Vandenhirtz, Samuel Ruiperez-Campillo, Max Krähenmann, Silke Mühlstedt, Irene Cannistraci, Ece Özkan Elsen, Julia E. Vogt, Thomas M. Sutter

cs.AI ·submitted 2026-09-10 17:49 UTC · v3

Abstract

Cardiovascular diagnosis and treatment rest on integrating complementary modalities, such as electrocardiogram, echocardiography, and chest X-rays, each capturing distinct but complementary aspects of cardiac pathophysiology. Yet most medical foundation models remain modality-specific, combining modalities only for finetuning or post-training. This discards the cross-modal evidence clinicians naturally integrate and ignores the structure within each modality. We introduce Latent-Attention Masked Autoencoder (LAMAE), a multimodal, structure-aware masked autoencoder that jointly learns patient-level representations during self-supervised pretraining. Instead of fusing modalities post hoc, LAMAE exchanges information directly in the latent space through a shared latent-attention module operating over a study-view-entity hierarchy, enabling aggregation of variable observations and handling of missing modalities. Pretrained on over 500'000 MIMIC-IV hospital stays, LAMAE outperforms modality-specific pretraining and strong contrastive and vision-language baselines across multimodal hospital-stay tasks, such as in-hospital mortality, ICD-10 and DRG coding, and length of stay, while remaining competitive on unimodal tasks. Modeling this structure also pays off within a single modality: even without cross-modal information, the latent-attention module improves representations over modality-specific pretraining.

Closest papers

Nearest neighbours by meaning across the whole index.

MR-JEPA: A General Purpose Video Foundation Model for Cardiac MRI

cs.CV cs.AI ·2026-08-31 ·Athira J. Jacob, Puneet Sharma, Dorin Comaniciu, Daniel Rueckert
published similarity 0.72
Abstract · Accepted at STACOM 2026 (MICCAI 2026 peer-reviewed workshop)

Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep learning approaches process individual 2D slices, discarding this context. We present MR-JEPA, a self-supervised video foundation model for CMR that extends LeJEPA to 3D spatiotemporal inputs through tubelet tokenization, spatiotemporal masking augmentation, and initialization from a 2D CMR foundation model. Unlike prior CMR video models limited to cine data, MR-JEPA is pretrained on multi-sequence data (cine, LGE, mapping) from 10,505 patients across two centers without annotations. We evaluate the frozen encoder on six downstream tasks using a unified multi-view gated attention architecture: LV ejection fraction, RV ejection fraction, three myocardial strains (GLS, GCS, GRS), and four-class disease detection. MR-JEPA outperforms other compared methods on all five regression tasks, including both a domain-specific CMR model pretrained on more data with text supervision and a natural-video foundation model, achieving an LV EF MAE of 4.79% (r =0.764) and a GLS MAE of 1.87 (r=0.805), with 21-27% MAE reductions over baselines on strain tasks. For disease detection, MR-JEPA achieved a macro AUG of 0.868, remaining competitive with the domain-specific baseline despite using a fully self-supervised pretraining objective. These results demonstrate the potential of a unified video encoder for robust, multi-view utilization of diverse CMR sequences in clinical cardiac quantification and diagnosis.

0.31

CheXFuse: Guided Differential Joint Attention Fusion for Robust Multimodal Chest X-Ray Classification in Data-Scarce Medical Settings

cs.CV cs.LG ·2026-10-19 ·Muntaqim Ahmed Raju, Priyanka Siddappa, Md Shifat Haider Al Amin, Ruizhe Ma, Md Ripon Ahammed
publishedhighly cited similarity 0.69
Abstract · IEEE ICDM DMBIH 2026

A central challenge in multimodal learning is how to fuse modalities that differ substantially in predictive strength. When one modality provides a much stronger representation than another, indiscriminate cross-modal interaction can introduce weak, redundant, or unstable signals, limiting or even degrading performance relative to the strongest unimodal representation. To address this problem, we propose CheXFuse, a multimodal fusion framework based on Guided Differential Joint Attention (GuDJA). CheXFuse combines image and text token representations within a joint multimodal sequence, where learned token guidance emphasizes informative representations and differential attention reduces less useful attention responses. We evaluate CheXFuse on the Indiana University (IU) Chest X-ray dataset, using binary (normal vs. abnormal) classification as the downstream task. Experiments are conducted under both original-report and masked-report settings, with the latter serving as a controlled stress test under reduced textual informativeness. CheXFuse with GuDJA achieves the strongest mean overall performance across the evaluated baselines and ablations, reaching 95.73% accuracy, 95.79% F1-score, 96.54% recall, and 95.28% sensitivity at 95% specificity (Sens@95Spec) with original reports, and 95.58%, 95.60%, 95.60%, and 94.34%, respectively, under masked reports. These results suggest that GuDJA provides a promising fusion strategy under asymmetric or partially reduced modality informativeness.

0.49

TRACE: Expert-Aligned ECG Representation Learning with Rigorous Benchmarking and Real-World Validation in Acute Cardiac Care

cs.LG cs.AI ·2026-09-28 ·Lovely Yeswanth Panchumarthi, Andrew Lu, Saurabh Kataria, Delgersuren Bold, Minxiao Wang +9 more
benchmark similarity 0.68
Abstract · 42 pages, 4 figures and 1 table

TRACE (Text-Reinforced Analysis of Cardio ECGs) is a multimodal electrocardiogram (ECG) representation model that learns clinically grounded signal embeddings for downstream cardiac classification. It is designed to address the limitations of existing CLIP-style training, which often struggles with noisy clinical text and fails to leverage the complementary strengths of unimodal (from ECG) and cross-modal (between ECG and matched cardiologist reports) learning. To bridge this gap, we propose a hybrid architecture that jointly learns unimodal and cross-modal representations via uncertainty-weighted multi-task learning while utilizing an LLM-based pipeline to extract high-fidelity findings from cardiologist reports. We evaluate TRACE across a spectrum of clinical urgency, establishing robust performance on public benchmarks for arrhythmia classification and structural abnormalities relative to existing unimodal and multimodal ECG models. To demonstrate real-world utility, we further validate the model on acute coronary occlusion (ACO), where the prevailing ST-elevation criteria miss 25-34% of true occlusions. Utilizing a large private ACO dataset with expert-annotated ground truth, TRACE significantly outperforms real-world clinical practice, yielding a 19.0% increase in sensitivity or a 62.6% reduction in false positive rates at the clinical baseline. This extensive evaluation confirms that TRACE delivers both strong performance on benchmark tasks and tangible clinical impact in the most acute, high-risk cardiac scenarios.

0.11

Learning Where to Look: Anatomical Grounding and Guided Attention for Cardiac MRI Vision-Language Models

cs.CV ·2026-09-30 ·Bangwei Guo, Xiao Chen, Boris Mailhe, Jia Yao, Yiqing Wang +6 more
similarity 0.68
Abstract

Cardiac magnetic resonance imaging (CMR) enables assessment of cardiac anatomy, ventricular function, and myocardial tissue characteristics. Clinicians interpret these images by identifying cardiac structures and focusing on the regions relevant to each clinical question, motivating anatomically guided vision-language models (VLMs). Yet CMR-specific supervision for anatomical localisation and clinical question answering remains limited. To address this gap, we investigate fine-grained CMR visual question answering through anatomical grounding and guided attention. We construct 128,915 anatomical-grounding and 42,799 clinical QA pairs across short-axis cine, late gadolinium enhancement, and long-axis cine. These datasets support anatomical recognition, localisation, and clinical assessment without requiring paired reports for individual training images. To help the model learn where to look, we introduce Cardiac Anatomy-Routed Attention (CARA), which selects predicted anatomical priors according to the question and guides decoder attention with learned task-specific strengths. Combining anatomical grounding pretraining with CARA yields our model, CARA-VL. Experiments demonstrate CARA-VL's strengths in clinical assessment and regional localisation across CMR imaging settings, with promising generalization to an external clinical cohort. Together, our data and method provide a practical framework for studying and advancing cardiac visual understanding in VLMs. We will release the QA data derived from public datasets upon publication.

0.36

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

cs.LG eess.IVstat.ML ·2026-08-13 ·Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu +1 more
similarity 0.68
Abstract

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.

0.42

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.68
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

LoRe-MIM: Lost-or-Replaced Masked Image Modeling for Self-Supervised Representation Learning in Whole-Body PET/CT

cs.CV ·2026-10-29 ·Amartya Bhattacharya, Bashirul Azam Biswas, Biratal Raj Wagle, Michael S. Leapman, Matthew E. Maeder +2 more
similarity 0.67
Abstract · 25 pages, 9 figures

Deep learning models for whole-body positron emission tomography/computed tomography (PET/CT) hold significant clinical potential for disease detection, treatment planning, and response assessment. However, the time and cost associated with expert annotations remain major bottlenecks in developing robust and generalizable models. Although self-supervised learning (SSL) has emerged as a promising approach to mitigating annotation scarcity, its application to whole-body PET/CT remains relatively underexplored due to the limited availability of large-scale datasets and the challenges associated with learning complementary cross-modal representations. To address these limitations, we curate a heterogeneous, multi-tracer, multi-institutional cohort comprising 6,531 whole-body PET/CT scans and propose LoRe-MIM (Lost-Or-Replaced Masked Image Modelling), a novel self-supervised framework designed to learn multimodal representations through masked image reconstruction. Specifically, LoRe-MIM introduces a masking strategy in which image regions are either replaced with zeros (Lost) or substituted with corresponding complementary imaging modality (Replaced), encouraging the model to capture both modality-specific characteristics and cross-modal relationships. We evaluate the learned representations across multiple downstream tasks, including multimodal PET/CT image reconstruction, patch-based classification into cancer vs. non-cancer, whole-body lesion segmentation, label-efficient training, and robustness assessment. Experimental results demonstrate that LoRe-MIM consistently outperforms the corresponding state-of-the-art baselines across these tasks, highlighting its potential as a scalable and generalizable self-supervised learning framework for whole-body PET/CT analysis.

0.20

CXR-CMFA: A Cross-Modal Feature Aggregation Network for Chest X-Ray Pathology Classification

cs.CV cs.AI ·2026-11-06 ·Talukder Hasnat Zadid, Jahin Sultana, Felipe Bochini Brisola, Kishore Roy, Mysha Rahman +2 more
benchmark similarity 0.67
Abstract

Chest X-ray (CXR) interpretation remains challenging because subtle pathology can be obscured by overlapping anatomy, image-quality variation, and limited visual evidence in isolated radiographs. Although image-only deep learning models provide useful baselines, they discard the complementary diagnostic context available in radiology reports, while large vision-language models can be computationally expensive for practical deployment. This paper presents CXR-CMFA, a lightweight cross-modal feature aggregation network for binary CXR pathology classification. The proposed framework combines a dual-stream visual encoder, using EfficientNet-B0 for global anatomical representation and DenseNet-121 for local pathological detail, with a TF-IDF-MLP report encoder. Two fusion modules integrate these modalities: the Dual-Modal Spatial Attention Module (DMSAM) uses the report embedding to gate global and local visual features, and the Cross-Modal Gated Feature Fusion (CGFF) module learns per-instance weights for visual and textual contributions. Experiments on the MIMIC-CXR benchmark, using the provided train, validation, and test splits, show that CXR-CMFA achieves 93.45% accuracy, 99.88% precision, 91.8% recall, 95.7% F1-score, and 99.19% AUC on the held-out test set. The model produces only four false positives among 984 normal test cases, supporting its suitability for high-specificity screening workflows. An ablation study further demonstrates a 22.47 percentage-point AUC improvement over the global-image-only variant, confirming the value of adaptive cross-modal fusion. These results indicate that compact report-conditioned fusion can provide strong discriminative performance without relying on large pretrained language models.

0.14