CS Paper Radar

TRACE: Expert-Aligned ECG Representation Learning with Rigorous Benchmarking and Real-World Validation in Acute Cardiac Care

Lovely Yeswanth Panchumarthi, Andrew Lu, Saurabh Kataria, Delgersuren Bold, Minxiao Wang, Runze Yan, Patricia Dykes, Brian J. Gow, Tom J. Pollard, Jessica K. Zègre-Hemsey, Dillon J. Dzikowicz, Lekshmi Kumar, Xiao Hu, Ran Xiao

cs.LG cs.AI ·submitted 2026-09-28 01:26 UTC · v1
benchmark

Abstract

TRACE (Text-Reinforced Analysis of Cardio ECGs) is a multimodal electrocardiogram (ECG) representation model that learns clinically grounded signal embeddings for downstream cardiac classification. It is designed to address the limitations of existing CLIP-style training, which often struggles with noisy clinical text and fails to leverage the complementary strengths of unimodal (from ECG) and cross-modal (between ECG and matched cardiologist reports) learning. To bridge this gap, we propose a hybrid architecture that jointly learns unimodal and cross-modal representations via uncertainty-weighted multi-task learning while utilizing an LLM-based pipeline to extract high-fidelity findings from cardiologist reports. We evaluate TRACE across a spectrum of clinical urgency, establishing robust performance on public benchmarks for arrhythmia classification and structural abnormalities relative to existing unimodal and multimodal ECG models. To demonstrate real-world utility, we further validate the model on acute coronary occlusion (ACO), where the prevailing ST-elevation criteria miss 25-34% of true occlusions. Utilizing a large private ACO dataset with expert-annotated ground truth, TRACE significantly outperforms real-world clinical practice, yielding a 19.0% increase in sensitivity or a 62.6% reduction in false positive rates at the clinical baseline. This extensive evaluation confirms that TRACE delivers both strong performance on benchmark tasks and tangible clinical impact in the most acute, high-risk cardiac scenarios.

Comment
42 pages, 4 figures and 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

Holtercare-Bench: A Multimodal Benchmark for Evaluating Long-Term Dynamic ECG Analysis

cs.LG ·2026-08-19 ·Yihan Xie, Hanwen Cui, Runze Ye, Juekai Lin, Haoyang Wang +6 more
top venuebenchmarkcode/data similarity 0.73
Abstract

While multimodal large language models (MLLMs) excel in medical applications, most of them favor static images or short-term signals. In the critical field of dynamic electrocardiograms (ECG), models struggle with complex temporal reasoning and diagnostic report generation due to a lack of high-quality datasets and benchmarks. To address this, we introduce (i) Holtercare-23K, a large-scale multimodal dynamic ECG dataset comprising 22,980 QA pairs derived from 788 clinical Holter records and featuring a novel signal-video-text tri-modal alignment. Based on this dataset, we present (ii) Holtercare-Bench, a multimodal benchmark that evaluates models on temporal localization, clinical diagnosis, and global summarization. Zero-shot evaluations of leading MLLMs reveal a significant performance gap in processing ultra-long pathological sequences. However, fine-tuning representative models yields substantial improvements. This work illuminates the limitations of current MLLMs in electrophysiology and provides a foundational benchmark for long-term medical MLLMs. Our project is available at https://github.com/ZJU4HealthCare/Holtercare-Bench.

0.47

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.73
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.32

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.72
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

Reading the Whole Heart: Latent-Attention Masked Autoencoders for Multimodal Cardiac Representation Learning

cs.AI ·2026-09-10 ·Andrea Agostini, Simon Böhi, Moritz Vandenhirtz, Samuel Ruiperez-Campillo, Max Krähenmann +5 more
similarity 0.68
Abstract

Cardiovascular diagnosis and treatment rest on integrating complementary modalities, such as electrocardiogram, echocardiography, and chest X-rays, each capturing distinct but complementary aspects of cardiac pathophysiology. Yet most medical foundation models remain modality-specific, combining modalities only for finetuning or post-training. This discards the cross-modal evidence clinicians naturally integrate and ignores the structure within each modality. We introduce Latent-Attention Masked Autoencoder (LAMAE), a multimodal, structure-aware masked autoencoder that jointly learns patient-level representations during self-supervised pretraining. Instead of fusing modalities post hoc, LAMAE exchanges information directly in the latent space through a shared latent-attention module operating over a study-view-entity hierarchy, enabling aggregation of variable observations and handling of missing modalities. Pretrained on over 500'000 MIMIC-IV hospital stays, LAMAE outperforms modality-specific pretraining and strong contrastive and vision-language baselines across multimodal hospital-stay tasks, such as in-hospital mortality, ICD-10 and DRG coding, and length of stay, while remaining competitive on unimodal tasks. Modeling this structure also pays off within a single modality: even without cross-modal information, the latent-attention module improves representations over modality-specific pretraining.

0.11

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.68
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.41

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.68
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32

IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for Electrocardiogram

cs.AI ·2026-10-20 ·Huynh Dang Nguyen, Trong-Thang Pham, Anh-Thuan Do, Phuong-Nhi Dinh, Brijesh Patel +2 more
published similarity 0.67
Abstract · Accepted in WACV 2027

Electrocardiography (ECG) is a cornerstone of cardiac diagnosis, yet most machine learning methods for ECG analysis lack interpretability, limiting their clinical adoption. We present IECG, a weakly-supervised ECG foundation model that jointly performs diagnostic classification and abnormality localization without requiring manual abnormal region annotations, overcoming a long-standing bottleneck in interpretable ECG learning. Central to IECG is a weakly-supervised attention strategy that explicitly incorporates clinical priors by deriving abnormality heatmap pseudo-labels from established ECG clinical knowledge. These pseudo-labels guide the model's CLS-token attention through a KL-divergence loss, encouraging it to focus on diagnostically relevant waveform regions. During pretraining, IECG is jointly optimized with clinically guided attention supervision, ECG-text contrastive alignment, and report captioning objectives, enabling it to learn rich multimodal representations while producing localized waveform evidence. By explicitly aggregating features from clinically guided attention regions, IECG grounds its diagnostic predictions in interpretable waveform evidence without sacrificing classification performance. Extensive experiments demonstrate that IECG achieves state-of-the-art abnormal region localization while maintaining strong classification performance, advancing trustworthy foundation models for ECG analysis.

0.31

ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography

cs.CL cs.IR ·2026-08-31 ·Mohammadsina Hassannia, Matthew A. Reyna, Reza Sameni
benchmarkcode/data similarity 0.67
Abstract

Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.

0.35