Abstract

Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.

Closest papers

Nearest neighbours by meaning across the whole index.

ECGJev: Question-Conditioned Option Scoring for 12-Lead ECG Interpretation

cs.LG eess.SP ·2026-11-01 ·Zhuoyuan Li, Xidong Wu, Hanyu Cui, Jiansong Gao, Rongrong Fu +2 more
code/datahot direction similarity 0.76
Abstract · 5 pages (4 pages plus ethics statement and references), 2 figures. Submitted to IEEE ISBI 2027. Zhuoyuan Li and Xidong Wu contributed equall…

Clinical interpretation of a 12-lead electrocardiogram (ECG) often requires answering targeted diagnostic questions with clear, quantifiable decisions. We introduce ECGJev, the first ECG framework built on a decision decoder, a pretrained language model trained to return a probability for every listed option. A question-conditioned bridge compresses frozen waveform and spectrogram features into 16 ECG tokens, and a two-stage procedure adapts the bridge and low-rank adapters on the decoder's native option readout using diagnostic labels alone, scoring all options for a question in one forward pass. Evaluated across four ECG benchmarks, ECGJev achieves the highest macro-F1 on CPSC2018 (80.46%), PTB-XL (71.68%) and Chapman (96.86%), and generalizes competitively to the small-sample PTB cohort. Concept probes and perturbation analyses further show that its predictions rely directly on the ECG input, remain stable under option-order and wording variations, and transfer zero-shot to unseen waveform concepts. Our code is available at https://github.com/zhuoyuanli-lab/ECGJev.

0.34

Diagnosing as Cardiologists Do: ECG Agents with Doctor-Grounded Priors for Clinical Reasoning Across Diseases and Populations

eess.SP cs.CVcs.LG ·2026-08-10 ·Hongxiang Gao, He-yang Xu, Yuwen Li, Minghui Zhao, Zhipeng Cai +4 more
benchmark similarity 0.69
Abstract

Cardiologists interpret electrocardiograms by localizing waveform components, measuring rhythm and interval patterns, and translating these structured observations into diagnostic evidence. Whether this expert reading process can serve as an effective prior for ECG agents remains unclear. To address this question, we introduce LuminaECG, a clinically structured ECG reasoning framework that reformulates ECG interpretation as measurement-grounded visual reading. ECG signals are rendered on standard electrocardiographic grid paper to preserve the spatial and scale cues used in clinical reading. P-wave, QRS-complex, and T-wave boundaries are explicitly delineated, and color-coded segmentation decomposes the waveform into discrete visual measurement primitives. A general 2B vision-language backbone is then trained with low-rank supervised fine-tuning to associate these primitives with diagnostic reasoning, without architectural modification. Across open, proprietary, and ECG-specialist zero-shot baselines, LuminaECG improves both waveform measurement and diagnostic recovery. It reaches a clinically meaningful reader tier on the CODE-test benchmark, transfers across geographically diverse ECG datasets without retraining, and generates reports whose structure contains an emergent prognostic signal. These findings suggest that effective ECG agents require not only larger models, but supervision that preserves the alignment between measurable waveform evidence and clinical knowledge.

0.04

Holtercare-Bench: A Multimodal Benchmark for Evaluating Long-Term Dynamic ECG Analysis

cs.LG ·2026-08-19 ·Yihan Xie, Hanwen Cui, Runze Ye, Juekai Lin, Haoyang Wang +6 more
top venuebenchmarkcode/data similarity 0.69
Abstract

While multimodal large language models (MLLMs) excel in medical applications, most of them favor static images or short-term signals. In the critical field of dynamic electrocardiograms (ECG), models struggle with complex temporal reasoning and diagnostic report generation due to a lack of high-quality datasets and benchmarks. To address this, we introduce (i) Holtercare-23K, a large-scale multimodal dynamic ECG dataset comprising 22,980 QA pairs derived from 788 clinical Holter records and featuring a novel signal-video-text tri-modal alignment. Based on this dataset, we present (ii) Holtercare-Bench, a multimodal benchmark that evaluates models on temporal localization, clinical diagnosis, and global summarization. Zero-shot evaluations of leading MLLMs reveal a significant performance gap in processing ultra-long pathological sequences. However, fine-tuning representative models yields substantial improvements. This work illuminates the limitations of current MLLMs in electrophysiology and provides a foundational benchmark for long-term medical MLLMs. Our project is available at https://github.com/ZJU4HealthCare/Holtercare-Bench.

0.47

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.69
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.32

TRACE: Expert-Aligned ECG Representation Learning with Rigorous Benchmarking and Real-World Validation in Acute Cardiac Care

cs.LG cs.AI ·2026-09-28 ·Lovely Yeswanth Panchumarthi, Andrew Lu, Saurabh Kataria, Delgersuren Bold, Minxiao Wang +9 more
benchmark similarity 0.67
Abstract · 42 pages, 4 figures and 1 table

TRACE (Text-Reinforced Analysis of Cardio ECGs) is a multimodal electrocardiogram (ECG) representation model that learns clinically grounded signal embeddings for downstream cardiac classification. It is designed to address the limitations of existing CLIP-style training, which often struggles with noisy clinical text and fails to leverage the complementary strengths of unimodal (from ECG) and cross-modal (between ECG and matched cardiologist reports) learning. To bridge this gap, we propose a hybrid architecture that jointly learns unimodal and cross-modal representations via uncertainty-weighted multi-task learning while utilizing an LLM-based pipeline to extract high-fidelity findings from cardiologist reports. We evaluate TRACE across a spectrum of clinical urgency, establishing robust performance on public benchmarks for arrhythmia classification and structural abnormalities relative to existing unimodal and multimodal ECG models. To demonstrate real-world utility, we further validate the model on acute coronary occlusion (ACO), where the prevailing ST-elevation criteria miss 25-34% of true occlusions. Utilizing a large private ACO dataset with expert-annotated ground truth, TRACE significantly outperforms real-world clinical practice, yielding a 19.0% increase in sensitivity or a 62.6% reduction in false positive rates at the clinical baseline. This extensive evaluation confirms that TRACE delivers both strong performance on benchmark tasks and tangible clinical impact in the most acute, high-risk cardiac scenarios.

0.11

CardioVascBench:Prioritized Diagnosis Generation from Real-World Chinese Cardiovascular Records

cs.CL ·2026-11-03 ·Minghao Kong, Muyao Chen, Jianhao Wu, Yuqiang Zhang, Xiangbin Meng +5 more
benchmark similarity 0.67
Abstract · 26 pages,17 figures,5 tables,including appendices

Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance. We introduce CardioVascBench, a retrospective benchmark for prioritized diagnosis generation from real-world Chinese cardiovascular inpatient records. It contains 3,262 de-identified cases, with 2,174 for training and 1,088 for evaluation, linking clinical narratives and textual ECG reports to expert-verified, ordered discharge diagnoses standardized to ICD-10. An English translation of the evaluation set supports aligned cross-lingual comparison. Our evaluation protocol combines terminology normalization and rank-aware scoring to separately assess primary-diagnosis identification, reference-diagnosis coverage, and list precision. Evaluation across 36 systems shows that higher primary-diagnosis accuracy does not necessarily imply higher list precision against discharge references. We also provide CardioKG-Agent, a knowledge-enhanced baseline combining entity normalization, constrained graph retrieval, and guideline evidence. In a staged comparison of three baseline models, supervised fine-tuning plus the agent achieves a 73.5% higher mean composite score than fine-tuning alone, representing a system-level gain. These results measure retrospective agreement with recorded diagnoses; agreement between metric rankings and physician judgments remains to be validated. CardioVascBench supports research on diagnosis prioritization and knowledge-enhanced generation.

0.20

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.67
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

RAG-TRACE: Tracing Measurement Evidence and Diagnostic Completeness in AI-Generated ECG Reports

cs.CL ·2026-11-01 ·Elyas Irankhah, Shahed Salehzehi, Parisa Hosseini
code/data similarity 0.67
Abstract · Code and study materials available at https://github.com/Elyasirankhah/RAG-TRACE

Purpose: Retrieval-augmented generation (RAG) can introduce electrocardiogram (ECG) criteria that lack patient-specific measurement support. This study evaluates the reliability of retrieved diagnostic criteria in AI-generated ECG reports. Methods: We analyzed 1,083 human-validated PTB-XL patient records using a library of 47 criteria cards, including 33 without numeric verification rules. Language models generated structured reports with and without retrieval. Criterion applicability was evaluated using Marquette 12SL measurements, with independent assessment using Uni-G and comparison against expert-validated diagnostic labels. Results: Keyword retrieval introduced untestable or measurement-disconfirmed criteria in 46.8% of GPT-4.1-mini reports. A deterministic verification rule withdrew 647 criterion applications, including 639 without numeric checks, while preserving 268 of 269 applications independently supported by Uni-G. Restricting retrieval to 14 testable criteria reduced the initial unsupported-criterion rate to 13.8%. Under matched instructions and an identical output schema, retrieval increased unsupported-criterion reports from 17.4% to 31.1%, while hypertrophy recall remained unchanged at 62.6%. Conclusion: These findings identify a fundamental limitation of retrieval-based clinical report generation: retrieved criteria do not necessarily provide valid patient-specific evidence. Measurement-based verification can reduce unsupported criterion applications, but diagnostic validity requires independent assessment.