CS Paper Radar

ECGJev: Question-Conditioned Option Scoring for 12-Lead ECG Interpretation

Zhuoyuan Li, Xidong Wu, Hanyu Cui, Jiansong Gao, Rongrong Fu, Mingke Yan, Haotian Tang

cs.LG eess.SP ·submitted 2026-11-01 16:39 UTC · v1
code/datahot direction

Abstract

Clinical interpretation of a 12-lead electrocardiogram (ECG) often requires answering targeted diagnostic questions with clear, quantifiable decisions. We introduce ECGJev, the first ECG framework built on a decision decoder, a pretrained language model trained to return a probability for every listed option. A question-conditioned bridge compresses frozen waveform and spectrogram features into 16 ECG tokens, and a two-stage procedure adapts the bridge and low-rank adapters on the decoder's native option readout using diagnostic labels alone, scoring all options for a question in one forward pass. Evaluated across four ECG benchmarks, ECGJev achieves the highest macro-F1 on CPSC2018 (80.46%), PTB-XL (71.68%) and Chapman (96.86%), and generalizes competitively to the small-sample PTB cohort. Concept probes and perturbation analyses further show that its predictions rely directly on the ECG input, remain stable under option-order and wording variations, and transfer zero-shot to unseen waveform concepts. Our code is available at https://github.com/zhuoyuanli-lab/ECGJev.

Comment
5 pages (4 pages plus ethics statement and references), 2 figures. Submitted to IEEE ISBI 2027. Zhuoyuan Li and Xidong Wu contributed equally

Closest papers

Nearest neighbours by meaning across the whole index.

ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography

cs.CL cs.IR ·2026-08-31 ·Mohammadsina Hassannia, Matthew A. Reyna, Reza Sameni
benchmarkcode/data similarity 0.76
Abstract

Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.

0.35

LEAP-LLM: Preserving lead-time structure for question-conditioned ECG interpretation

cs.LG cs.AI ·2026-11-13 ·Aakash Agarwal, Yidan Shen, Xin Fu, Renjie Hu
similarity 0.69
Abstract · 23 Pages including Appendix

The electrocardiogram (ECG) records cardiac electrical activity across multiple leads and is used for detecting cardiac abnormalities. Recent ECG-language models enable large language models (LLMs) to interpret cardiac signals and answer clinically relevant questions. However, existing ECG-language models typically encode the ECG independently of the clinical question, forcing the ECG representation to retain broad and potentially irrelevant signal information. Moreover, these models often aggregate information across leads which can obscure lead-specific details needed for a particular question. To tackle these limitations, we introduce LEAP-LLM, an ECG-LLM architecture for Lead-aware ECG Alignment with Prompt conditioning. LEAP-LLM uses the clinical question to guide ECG feature extraction while preserving explicit lead and temporal structure. Task-trained instruction representations distill information from the question and guide two complementary branches. The Lead branch captures question-relevant temporal patterns within each ECG lead, while the Temporal branch summarizes relevant information across leads at each temporal position. Together, they provide the LLM with compact, question-relevant ECG information while preserving lead and temporal structure. LEAP-LLM reduces modality-token count by 89.0% and prefill FLOPs by 7.2x on average relative to other ECG-LLMs baselines. Across four ECG benchmarks, LEAP-LLM achieves better performance, including a 3.4-percentage-point improvement in G12EC over the strongest prior ECG-specific method. We further show that the model adaptively emphasizes the clinically relevant anatomical lead groups for different cardiac abnormalities, with lead importance patterns consistent with established diagnostic knowledge, providing interpretable evidence that the predictions are supported by clinically meaningful ECG structure.

0.27

IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for Electrocardiogram

cs.AI ·2026-10-20 ·Huynh Dang Nguyen, Trong-Thang Pham, Anh-Thuan Do, Phuong-Nhi Dinh, Brijesh Patel +2 more
published similarity 0.68
Abstract · Accepted in WACV 2027

Electrocardiography (ECG) is a cornerstone of cardiac diagnosis, yet most machine learning methods for ECG analysis lack interpretability, limiting their clinical adoption. We present IECG, a weakly-supervised ECG foundation model that jointly performs diagnostic classification and abnormality localization without requiring manual abnormal region annotations, overcoming a long-standing bottleneck in interpretable ECG learning. Central to IECG is a weakly-supervised attention strategy that explicitly incorporates clinical priors by deriving abnormality heatmap pseudo-labels from established ECG clinical knowledge. These pseudo-labels guide the model's CLS-token attention through a KL-divergence loss, encouraging it to focus on diagnostically relevant waveform regions. During pretraining, IECG is jointly optimized with clinically guided attention supervision, ECG-text contrastive alignment, and report captioning objectives, enabling it to learn rich multimodal representations while producing localized waveform evidence. By explicitly aggregating features from clinically guided attention regions, IECG grounds its diagnostic predictions in interpretable waveform evidence without sacrificing classification performance. Extensive experiments demonstrate that IECG achieves state-of-the-art abnormal region localization while maintaining strong classification performance, advancing trustworthy foundation models for ECG analysis.

0.31

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.66
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.33

Diagnosing as Cardiologists Do: ECG Agents with Doctor-Grounded Priors for Clinical Reasoning Across Diseases and Populations

eess.SP cs.CVcs.LG ·2026-08-10 ·Hongxiang Gao, He-yang Xu, Yuwen Li, Minghui Zhao, Zhipeng Cai +4 more
benchmark similarity 0.66
Abstract

Cardiologists interpret electrocardiograms by localizing waveform components, measuring rhythm and interval patterns, and translating these structured observations into diagnostic evidence. Whether this expert reading process can serve as an effective prior for ECG agents remains unclear. To address this question, we introduce LuminaECG, a clinically structured ECG reasoning framework that reformulates ECG interpretation as measurement-grounded visual reading. ECG signals are rendered on standard electrocardiographic grid paper to preserve the spatial and scale cues used in clinical reading. P-wave, QRS-complex, and T-wave boundaries are explicitly delineated, and color-coded segmentation decomposes the waveform into discrete visual measurement primitives. A general 2B vision-language backbone is then trained with low-rank supervised fine-tuning to associate these primitives with diagnostic reasoning, without architectural modification. Across open, proprietary, and ECG-specialist zero-shot baselines, LuminaECG improves both waveform measurement and diagnostic recovery. It reaches a clinically meaningful reader tier on the CODE-test benchmark, transfers across geographically diverse ECG datasets without retraining, and generates reports whose structure contains an emergent prognostic signal. These findings suggest that effective ECG agents require not only larger models, but supervision that preserves the alignment between measurable waveform evidence and clinical knowledge.

0.04

ECG-Scroll: A Long-Horizon, Streaming Benchmark and Agent Environment for Interpretation of Ambulatory Electrocardiograms

cs.LG cs.AIcs.CLeess.SP ·2026-09-27 ·Haitao Li, Chenglin Li, Zhengyao Ding, Ziyu Li, Yiheng Mao +1 more
benchmark similarity 0.66
Abstract

Multimodal large language models (MLLMs) can now interpret a standard ten-second, twelve-lead electrocardiogram (ECG) with clinically grounded, reward-verified reasoning. Real cardiac monitoring is different. Ambulatory (Holter) and telemetry recordings span hours to days and are read as they stream in, and their clinically decisive findings are paroxysmal, brief episodes buried in an otherwise unremarkable trace. Such a recording cannot be held in one context at diagnostic resolution, and its future has not yet happened, so a reader must work online, deciding what to measure now, committing evidence to memory as it passes, and reporting events as they occur. We recast long-duration ECG interpretation as a long-horizon, online (streaming, causal) sequential decision process and introduce ECG-Scroll. As a benchmark, long ambulatory recordings are streamed to an agent chunk by chunk, and it must localize, quantify, and promptly flag paroxysmal events without access to future signal; because the underlying signal is retained, every answer is checkable against objective ground truth, giving rule-based rather than judge-based rewards, and the streaming formulation adds a metric batch evaluation cannot express, the detection latency between an event's onset and the moment the agent records it. As an agent environment, it is a fixed, gym-style interaction layer that exercises three competencies single-glance ECG models never touch: Memory, Tool use through signal-grounded measurement rather than reading pixels, and Planning of what to measure now and when to commit. We release 390 whole-recording instances spanning 2,536 hours of two-lead ambulatory ECG and evaluate a signal-threshold rule agent alongside off-the-shelf LLM agents online, characterizing how they use memory, tools, and planning and where the benchmark's head-room lies.

0.08

ECG Mirage: Revealing and Mitigating the Underutilisation of ECGs in Vision-Language Models for Clinical Prediction

cs.AI ·2026-09-18 ·Jinning Liang, Mingcheng Zhu, Tingting Zhu
similarity 0.65
Abstract

Emergency department (ED) decision-making relies on heterogeneous clinical information, including patient history, vital signs, laboratory results, and electrocardiograms (ECGs). Vision--language models (VLMs) can jointly process these modalities, but strong predictive performance does not necessarily imply meaningful use of the correct patient's ECG. We term this failure mode ECG Mirage: apparent multimodal capability without useful dependence on patient-specific ECG information. We distinguish two forms: ECG neglect, where ECGs provide little predictive benefit, and ECG confusion, where matched ECGs outperform no-image inputs but not mismatched ECGs. To evaluate these behaviours, we compare predictions obtained with matched ECGs, outcome-discordant mismatched ECGs, and no-image inputs while holding the clinical text and prediction targets fixed. Across four VLMs on MDS-ED, matched ECGs provide no consistent advantage for either ICU admission or clinical deterioration prediction. We then train four restricted visual prompts using supervised learning followed by conditional direct preference optimisation, while keeping the VLM backbone frozen. The resulting models achieve balanced accuracies of 70.6% for ICU admission and 67.5% for deterioration and increase the matched-versus-mismatched performance gap to approximately 16.5 and 5.5 percentage points, respectively. Overall, our study identifies ECG Mirage in multimodal clinical prediction and introduces visual prompt tuning as an efficient mitigation strategy.

0.36

RAG-TRACE: Tracing Measurement Evidence and Diagnostic Completeness in AI-Generated ECG Reports

cs.CL ·2026-11-01 ·Elyas Irankhah, Shahed Salehzehi, Parisa Hosseini
code/data similarity 0.64
Abstract · Code and study materials available at https://github.com/Elyasirankhah/RAG-TRACE

Purpose: Retrieval-augmented generation (RAG) can introduce electrocardiogram (ECG) criteria that lack patient-specific measurement support. This study evaluates the reliability of retrieved diagnostic criteria in AI-generated ECG reports. Methods: We analyzed 1,083 human-validated PTB-XL patient records using a library of 47 criteria cards, including 33 without numeric verification rules. Language models generated structured reports with and without retrieval. Criterion applicability was evaluated using Marquette 12SL measurements, with independent assessment using Uni-G and comparison against expert-validated diagnostic labels. Results: Keyword retrieval introduced untestable or measurement-disconfirmed criteria in 46.8% of GPT-4.1-mini reports. A deterministic verification rule withdrew 647 criterion applications, including 639 without numeric checks, while preserving 268 of 269 applications independently supported by Uni-G. Restricting retrieval to 14 testable criteria reduced the initial unsupported-criterion rate to 13.8%. Under matched instructions and an identical output schema, retrieval increased unsupported-criterion reports from 17.4% to 31.1%, while hypertrophy recall remained unchanged at 62.6%. Conclusion: These findings identify a fundamental limitation of retrieval-based clinical report generation: retrieved criteria do not necessarily provide valid patient-specific evidence. Measurement-based verification can reduce unsupported criterion applications, but diagnostic validity requires independent assessment.

0.41