CS Paper Radar

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel, Salar Abbaspourazad, Anshuman Mishra, Guillermo Sapiro, Andrew C. Miller, Joseph Futoma

cs.LG ·submitted 2026-10-06 02:58 UTC · v2

Abstract

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

Comment
Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Closest papers

Nearest neighbours by meaning across the whole index.

IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for Electrocardiogram

cs.AI ·2026-10-20 ·Huynh Dang Nguyen, Trong-Thang Pham, Anh-Thuan Do, Phuong-Nhi Dinh, Brijesh Patel +2 more
published similarity 0.78
Abstract · Accepted in WACV 2027

Electrocardiography (ECG) is a cornerstone of cardiac diagnosis, yet most machine learning methods for ECG analysis lack interpretability, limiting their clinical adoption. We present IECG, a weakly-supervised ECG foundation model that jointly performs diagnostic classification and abnormality localization without requiring manual abnormal region annotations, overcoming a long-standing bottleneck in interpretable ECG learning. Central to IECG is a weakly-supervised attention strategy that explicitly incorporates clinical priors by deriving abnormality heatmap pseudo-labels from established ECG clinical knowledge. These pseudo-labels guide the model's CLS-token attention through a KL-divergence loss, encouraging it to focus on diagnostically relevant waveform regions. During pretraining, IECG is jointly optimized with clinically guided attention supervision, ECG-text contrastive alignment, and report captioning objectives, enabling it to learn rich multimodal representations while producing localized waveform evidence. By explicitly aggregating features from clinically guided attention regions, IECG grounds its diagnostic predictions in interpretable waveform evidence without sacrificing classification performance. Extensive experiments demonstrate that IECG achieves state-of-the-art abnormal region localization while maintaining strong classification performance, advancing trustworthy foundation models for ECG analysis.

0.31

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.75
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.21

Robust Transfer Learning for Paper ECG Recognition

cs.LG cs.AI ·2026-09-30 ·Yinghao Xie, Zhenbang Dai, Haojun Wang, Jinyu Cai, Fabio Bonassi +4 more
similarity 0.74
Abstract

Paper ECG recognition is challenging because real-world ECG images vary in layout, physical artifacts, and label availability. We introduce RobECG-CL, a rank-aware contrastive learning framework for robust paper ECG representation learning. Starting from standard 12-lead ECG recordings, we construct progressively degraded paper ECG views with heterogeneous layouts and train the model to balance same-recording invariance with degradation-aware ordering. Across synthetic stress tests on CODE-II and EchoNext, RobECG-CL improves robustness under severe degradation and few-shot transfer, outperforming contrastive learning baselines and surpassing the waveform-based foundation model, ECG-FM, in the 1% labeled setting. On 312 samples of hospital data with 37 labels, RobECG-CL achieves the best macro AUROC.

0.16

TRACE: Expert-Aligned ECG Representation Learning with Rigorous Benchmarking and Real-World Validation in Acute Cardiac Care

cs.LG cs.AI ·2026-09-28 ·Lovely Yeswanth Panchumarthi, Andrew Lu, Saurabh Kataria, Delgersuren Bold, Minxiao Wang +9 more
benchmark similarity 0.73
Abstract · 42 pages, 4 figures and 1 table

TRACE (Text-Reinforced Analysis of Cardio ECGs) is a multimodal electrocardiogram (ECG) representation model that learns clinically grounded signal embeddings for downstream cardiac classification. It is designed to address the limitations of existing CLIP-style training, which often struggles with noisy clinical text and fails to leverage the complementary strengths of unimodal (from ECG) and cross-modal (between ECG and matched cardiologist reports) learning. To bridge this gap, we propose a hybrid architecture that jointly learns unimodal and cross-modal representations via uncertainty-weighted multi-task learning while utilizing an LLM-based pipeline to extract high-fidelity findings from cardiologist reports. We evaluate TRACE across a spectrum of clinical urgency, establishing robust performance on public benchmarks for arrhythmia classification and structural abnormalities relative to existing unimodal and multimodal ECG models. To demonstrate real-world utility, we further validate the model on acute coronary occlusion (ACO), where the prevailing ST-elevation criteria miss 25-34% of true occlusions. Utilizing a large private ACO dataset with expert-annotated ground truth, TRACE significantly outperforms real-world clinical practice, yielding a 19.0% increase in sensitivity or a 62.6% reduction in false positive rates at the clinical baseline. This extensive evaluation confirms that TRACE delivers both strong performance on benchmark tasks and tangible clinical impact in the most acute, high-risk cardiac scenarios.

0.11

Diagnosing as Cardiologists Do: ECG Agents with Doctor-Grounded Priors for Clinical Reasoning Across Diseases and Populations

eess.SP cs.CVcs.LG ·2026-08-10 ·Hongxiang Gao, He-yang Xu, Yuwen Li, Minghui Zhao, Zhipeng Cai +4 more
benchmark similarity 0.73
Abstract

Cardiologists interpret electrocardiograms by localizing waveform components, measuring rhythm and interval patterns, and translating these structured observations into diagnostic evidence. Whether this expert reading process can serve as an effective prior for ECG agents remains unclear. To address this question, we introduce LuminaECG, a clinically structured ECG reasoning framework that reformulates ECG interpretation as measurement-grounded visual reading. ECG signals are rendered on standard electrocardiographic grid paper to preserve the spatial and scale cues used in clinical reading. P-wave, QRS-complex, and T-wave boundaries are explicitly delineated, and color-coded segmentation decomposes the waveform into discrete visual measurement primitives. A general 2B vision-language backbone is then trained with low-rank supervised fine-tuning to associate these primitives with diagnostic reasoning, without architectural modification. Across open, proprietary, and ECG-specialist zero-shot baselines, LuminaECG improves both waveform measurement and diagnostic recovery. It reaches a clinically meaningful reader tier on the CODE-test benchmark, transfers across geographically diverse ECG datasets without retraining, and generates reports whose structure contains an emergent prognostic signal. These findings suggest that effective ECG agents require not only larger models, but supervision that preserves the alignment between measurable waveform evidence and clinical knowledge.

0.04

Holtercare-Bench: A Multimodal Benchmark for Evaluating Long-Term Dynamic ECG Analysis

cs.LG ·2026-08-19 ·Yihan Xie, Hanwen Cui, Runze Ye, Juekai Lin, Haoyang Wang +6 more
top venuebenchmarkcode/data similarity 0.71
Abstract

While multimodal large language models (MLLMs) excel in medical applications, most of them favor static images or short-term signals. In the critical field of dynamic electrocardiograms (ECG), models struggle with complex temporal reasoning and diagnostic report generation due to a lack of high-quality datasets and benchmarks. To address this, we introduce (i) Holtercare-23K, a large-scale multimodal dynamic ECG dataset comprising 22,980 QA pairs derived from 788 clinical Holter records and featuring a novel signal-video-text tri-modal alignment. Based on this dataset, we present (ii) Holtercare-Bench, a multimodal benchmark that evaluates models on temporal localization, clinical diagnosis, and global summarization. Zero-shot evaluations of leading MLLMs reveal a significant performance gap in processing ultra-long pathological sequences. However, fine-tuning representative models yields substantial improvements. This work illuminates the limitations of current MLLMs in electrophysiology and provides a foundational benchmark for long-term medical MLLMs. Our project is available at https://github.com/ZJU4HealthCare/Holtercare-Bench.

0.47

ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography

cs.CL cs.IR ·2026-08-31 ·Mohammadsina Hassannia, Matthew A. Reyna, Reza Sameni
benchmarkcode/data similarity 0.69
Abstract

Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.

0.35

Leveraging Cardiac Imaging to Improve ECG-Based Detection of Chagas Disease in Resource-Constrained Settings

cs.LG cs.AIeess.IV ·2026-09-08 ·Laura Alvarez-Florez, Daniel Uyterlinde, Samuel Ruipérez-Campillo, Lukas P. A. Arts, Folkert W. Asselbergs +1 more
similarity 0.68
Abstract

Chagas disease is a major cause of cardiomyopathy in Latin America. Cardiac magnetic resonance (CMR) imaging can characterize its structural abnormalities, but scanners and expert readers remain scarce in endemic regions. Electrocardiography (ECG) is inexpensive and widely available, yet structural disease must be inferred indirectly from electrical signals. We propose to transfer CMR-derived structural knowledge to ECG through contrastive pre-training. Using 63,193 paired ECG-CMR examinations from the UK Biobank, we align an ECG encoder with a clinically grounded CMR embedding space using an asymmetric InfoNCE objective. Despite seeing no Chagas cases during pre-training, the resulting representation improves ECG-based Chagas detection. Across CODE-15% and SaMi-Trop, a frozen linear probe achieves an AUROC of 0.851 and sensitivity at the top 5% of predicted risk (Top5%-TPR) of 0.427 in five-fold cross-validation, compared with 0.827 and 0.377 for an unaligned ECG-FM baseline. On the PhysioNet/CinC 2025 Challenge test set, our model obtains the highest AUROC on SaMi-Trop-3 and the best ELSA-Brasil challenge score among the three top-performing methods, indicating that imaging-supervised ECG representations can generalize to populations and settings beyond the pre-training distribution.

0.12