CS Paper Radar

Leveraging Cardiac Imaging to Improve ECG-Based Detection of Chagas Disease in Resource-Constrained Settings

Laura Alvarez-Florez, Daniel Uyterlinde, Samuel Ruipérez-Campillo, Lukas P. A. Arts, Folkert W. Asselbergs, Fleur V. Y. Tjong

cs.LG cs.AIeess.IV ·submitted 2026-09-08 11:17 UTC · v1

Abstract

Chagas disease is a major cause of cardiomyopathy in Latin America. Cardiac magnetic resonance (CMR) imaging can characterize its structural abnormalities, but scanners and expert readers remain scarce in endemic regions. Electrocardiography (ECG) is inexpensive and widely available, yet structural disease must be inferred indirectly from electrical signals. We propose to transfer CMR-derived structural knowledge to ECG through contrastive pre-training. Using 63,193 paired ECG-CMR examinations from the UK Biobank, we align an ECG encoder with a clinically grounded CMR embedding space using an asymmetric InfoNCE objective. Despite seeing no Chagas cases during pre-training, the resulting representation improves ECG-based Chagas detection. Across CODE-15% and SaMi-Trop, a frozen linear probe achieves an AUROC of 0.851 and sensitivity at the top 5% of predicted risk (Top5%-TPR) of 0.427 in five-fold cross-validation, compared with 0.827 and 0.377 for an unaligned ECG-FM baseline. On the PhysioNet/CinC 2025 Challenge test set, our model obtains the highest AUROC on SaMi-Trop-3 and the best ELSA-Brasil challenge score among the three top-performing methods, indicating that imaging-supervised ECG representations can generalize to populations and settings beyond the pre-training distribution.

Closest papers

Nearest neighbours by meaning across the whole index.

Cardiac MRI-informed electrocardiography enables biologically grounded cardiomyopathy detection

cs.AI q-bio.QM ·2026-11-18 ·Zhengyao Ding, Kewen Wang, Yujian Hu, Ziyu Li, Yiheng Mao +25 more
similarity 0.76
Abstract · 46 pages, 9 figures

Precise myocardial phenotyping at population scale is limited by the cost and accessibility of cardiac magnetic resonance (CMR), whereas electrocardiography (ECG) is widely available but reflects electrical rather than structural and functional information. Here we develop MyoECG, a cross-modal representation learning framework that distils myocardial structural and functional knowledge from CMR into standard 12-lead ECGs, enabling imaging-informed cardiomyopathy detection and subtype classification from ECGs alone. MyoECG was pretrained on 45,241 paired ECG-CMR examinations from UK Biobank and a tertiary cardiovascular centre, then developed and validated across more than 1.8 million ECGs from seven independent datasets. Across internal and external datasets spanning prevalences of 0.2-54.7%, MyoECG outperformed five pretrained ECG foundation models, with AUROCs of 0.800-0.974 for cardiomyopathy detection. In a multi-reader study of six cardiologists, MyoECG assistance improved mean sensitivity by 0.109 (95% CI, 0.041-0.175; P = 0.009) and specificity by 0.056 (95% CI, 0.004-0.108; P = 0.040). In 41,128 UK Biobank participants, the MyoECG score showed genetic correlations with cardiomyopathy (rg = 0.409) and dilated cardiomyopathy (rg = 0.371), genome-wide associations at four loci, including regions mapped to NFIA and KCNQ1, and associations with 69 circulating proteins related to myocardial stress, cell adhesion, vascular biology and metabolism. The cardiomyopathy correlation attenuated to non-significance after adjustment for 27 measured CMR traits (rg = 0.131; P = 0.143), indicating that the score captures CMR-derived information rather than dataset-specific shortcuts. MyoECG offers a scalable route to CMR-informed cardiomyopathy assessment and a strategy for transferring knowledge from resource-intensive imaging to widely deployable physiological signals.

0.15

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.68
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.32

Learning from VAE Errors to support ECG-based Differential Diagnosis of Myocardial Scar

cs.LG stat.ML ·2026-09-04 ·Shayan Sharifi, Riccardo Treu, Ilaria Gandin, Federico Garoia, Marco Merlo +1 more
similarity 0.68
Abstract · Accepted at the PharML Workshop, ECML PKDD 2026

Late Gadolinium Enhancement (LGE) on cardiac magnetic resonance is a key marker of myocardial scar, but its limited accessibility motivates routine ECG-based screening. We evaluated whether $β$-variational autoencoder (VAE)-derived ECG representations can discriminate LGE+ from LGE- cardiomyopathic patients in a local cohort of 300 subjects. We compared 32-dimensional features from the foundation ECGx.AI model with those from a shallower $β$-VAE trained on normal PTB-XL ECGs, evaluating downstream classification and Dynamic Time Warping (DTW)-based reconstruction errors. ECGx.AI reached an area under ROC of 0.686 with Random Forest, while the proposed $β$-VAE reached 0.577 with sensitivity of 0.775 with Gradient Boosting. Notably, DTW-reconstruction errors significantly differed between classes in 10 out of 12 leads according to Mann-Whitney U test and help in classification, leading to an area under ROC of 0.643 with Logistic Regression, supporting their potential as markers of scar-related ECG alterations.

0.22

Robust Transfer Learning for Paper ECG Recognition

cs.LG cs.AI ·2026-09-30 ·Yinghao Xie, Zhenbang Dai, Haojun Wang, Jinyu Cai, Fabio Bonassi +4 more
similarity 0.65
Abstract

Paper ECG recognition is challenging because real-world ECG images vary in layout, physical artifacts, and label availability. We introduce RobECG-CL, a rank-aware contrastive learning framework for robust paper ECG representation learning. Starting from standard 12-lead ECG recordings, we construct progressively degraded paper ECG views with heterogeneous layouts and train the model to balance same-recording invariance with degradation-aware ordering. Across synthetic stress tests on CODE-II and EchoNext, RobECG-CL improves robustness under severe degradation and few-shot transfer, outperforming contrastive learning baselines and surpassing the waveform-based foundation model, ECG-FM, in the 1% labeled setting. On 312 samples of hospital data with 37 labels, RobECG-CL achieves the best macro AUROC.

0.16

Diagnosing as Cardiologists Do: ECG Agents with Doctor-Grounded Priors for Clinical Reasoning Across Diseases and Populations

eess.SP cs.CVcs.LG ·2026-08-10 ·Hongxiang Gao, He-yang Xu, Yuwen Li, Minghui Zhao, Zhipeng Cai +4 more
benchmark similarity 0.65
Abstract

Cardiologists interpret electrocardiograms by localizing waveform components, measuring rhythm and interval patterns, and translating these structured observations into diagnostic evidence. Whether this expert reading process can serve as an effective prior for ECG agents remains unclear. To address this question, we introduce LuminaECG, a clinically structured ECG reasoning framework that reformulates ECG interpretation as measurement-grounded visual reading. ECG signals are rendered on standard electrocardiographic grid paper to preserve the spatial and scale cues used in clinical reading. P-wave, QRS-complex, and T-wave boundaries are explicitly delineated, and color-coded segmentation decomposes the waveform into discrete visual measurement primitives. A general 2B vision-language backbone is then trained with low-rank supervised fine-tuning to associate these primitives with diagnostic reasoning, without architectural modification. Across open, proprietary, and ECG-specialist zero-shot baselines, LuminaECG improves both waveform measurement and diagnostic recovery. It reaches a clinically meaningful reader tier on the CODE-test benchmark, transfers across geographically diverse ECG datasets without retraining, and generates reports whose structure contains an emergent prognostic signal. These findings suggest that effective ECG agents require not only larger models, but supervision that preserves the alignment between measurable waveform evidence and clinical knowledge.

0.04

ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation

eess.IV cs.CVcs.LGphysics.med-ph ·2026-09-20 ·Omer Burak Demirel, Kelly K. Horst, Alessio Perazzolo, Elisa Bruno, Kenan Kaya +13 more
similarity 0.64
Abstract

Cardiovascular magnetic resonance (CMR) provides comprehensive cardiac assessment but remains underutilized because of the complexity of acquisition, post-processing, and interpretation. Existing artificial intelligence (AI) methods address isolated tasks, limiting clinical integration. We present ORION-CMR (On-scanner Reporting with Integrated fOunda-tioN Model), the first clinically evaluated scanner-native end-to-end CMR foundation model. Pretrained on 12,896,733 CMR images from 9,258 studies, ORION-CMR performs sequence classification, ventricular function assessment, late gadolinium enhancement (LGE) detection, binary and multiclass disease classification, and local large language model-based report generation in approximately 90 seconds. The framework. was evaluated on public benchmarks and clinically validated in a multi-vendor cohort of 68 subjects with normal examinations, congenital heart disease, dilated cardiomyopathy, and myocardial infarction. ORION-CMR outperformed supervised baselines and the previously published CMR foundation model (CMR-FM), achieving state-of-the-art performance for LGE classification and scar segmentation. Clinical evaluation achieved an AUC of 0.96 for normal-versus abnormal classification and 0.88 for multiclass disease classification, while generated reports demonstrated 81.4% agreement with expert interpretation. These results demonstrate the feasibility of real-time scanner-native AI-assisted CMR analysis and automated report generation.

0.15

ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography

cs.CL cs.IR ·2026-08-31 ·Mohammadsina Hassannia, Matthew A. Reyna, Reza Sameni
benchmarkcode/data similarity 0.63
Abstract

Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.

0.35

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.61
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17