CS Paper Radar

Cardiac MRI-informed electrocardiography enables biologically grounded cardiomyopathy detection

Zhengyao Ding, Kewen Wang, Yujian Hu, Ziyu Li, Yiheng Mao, Yue Wang, Haitao Li, Dengnan Zhang, Xuanhong Liu, Yue Wang, Jing Wang, Yue Chen, Longbo Wang, Mengjia Chen, Chengchen Zhao, Xuesen Chu, Yubin Zhang, Mor Peleg, Judith Somekh, Mingxuan Yuan, Hui Yan, Yue Gu, Fan Yi, Zhilong Jia, Zhentao Tang, Xi Hu, Fei Wu, Hongkun Zhang, Ting Chen, Zhengxing Huang

cs.AI q-bio.QM ·submitted 2026-11-18 06:16 UTC · v1

Abstract

Precise myocardial phenotyping at population scale is limited by the cost and accessibility of cardiac magnetic resonance (CMR), whereas electrocardiography (ECG) is widely available but reflects electrical rather than structural and functional information. Here we develop MyoECG, a cross-modal representation learning framework that distils myocardial structural and functional knowledge from CMR into standard 12-lead ECGs, enabling imaging-informed cardiomyopathy detection and subtype classification from ECGs alone. MyoECG was pretrained on 45,241 paired ECG-CMR examinations from UK Biobank and a tertiary cardiovascular centre, then developed and validated across more than 1.8 million ECGs from seven independent datasets. Across internal and external datasets spanning prevalences of 0.2-54.7%, MyoECG outperformed five pretrained ECG foundation models, with AUROCs of 0.800-0.974 for cardiomyopathy detection. In a multi-reader study of six cardiologists, MyoECG assistance improved mean sensitivity by 0.109 (95% CI, 0.041-0.175; P = 0.009) and specificity by 0.056 (95% CI, 0.004-0.108; P = 0.040). In 41,128 UK Biobank participants, the MyoECG score showed genetic correlations with cardiomyopathy (rg = 0.409) and dilated cardiomyopathy (rg = 0.371), genome-wide associations at four loci, including regions mapped to NFIA and KCNQ1, and associations with 69 circulating proteins related to myocardial stress, cell adhesion, vascular biology and metabolism. The cardiomyopathy correlation attenuated to non-significance after adjustment for 27 measured CMR traits (rg = 0.131; P = 0.143), indicating that the score captures CMR-derived information rather than dataset-specific shortcuts. MyoECG offers a scalable route to CMR-informed cardiomyopathy assessment and a strategy for transferring knowledge from resource-intensive imaging to widely deployable physiological signals.

Comment
46 pages, 9 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Leveraging Cardiac Imaging to Improve ECG-Based Detection of Chagas Disease in Resource-Constrained Settings

cs.LG cs.AIeess.IV ·2026-09-08 ·Laura Alvarez-Florez, Daniel Uyterlinde, Samuel Ruipérez-Campillo, Lukas P. A. Arts, Folkert W. Asselbergs +1 more
similarity 0.76
Abstract

Chagas disease is a major cause of cardiomyopathy in Latin America. Cardiac magnetic resonance (CMR) imaging can characterize its structural abnormalities, but scanners and expert readers remain scarce in endemic regions. Electrocardiography (ECG) is inexpensive and widely available, yet structural disease must be inferred indirectly from electrical signals. We propose to transfer CMR-derived structural knowledge to ECG through contrastive pre-training. Using 63,193 paired ECG-CMR examinations from the UK Biobank, we align an ECG encoder with a clinically grounded CMR embedding space using an asymmetric InfoNCE objective. Despite seeing no Chagas cases during pre-training, the resulting representation improves ECG-based Chagas detection. Across CODE-15% and SaMi-Trop, a frozen linear probe achieves an AUROC of 0.851 and sensitivity at the top 5% of predicted risk (Top5%-TPR) of 0.427 in five-fold cross-validation, compared with 0.827 and 0.377 for an unaligned ECG-FM baseline. On the PhysioNet/CinC 2025 Challenge test set, our model obtains the highest AUROC on SaMi-Trop-3 and the best ELSA-Brasil challenge score among the three top-performing methods, indicating that imaging-supervised ECG representations can generalize to populations and settings beyond the pre-training distribution.

0.12

Learning from VAE Errors to support ECG-based Differential Diagnosis of Myocardial Scar

cs.LG stat.ML ·2026-09-04 ·Shayan Sharifi, Riccardo Treu, Ilaria Gandin, Federico Garoia, Marco Merlo +1 more
similarity 0.68
Abstract · Accepted at the PharML Workshop, ECML PKDD 2026

Late Gadolinium Enhancement (LGE) on cardiac magnetic resonance is a key marker of myocardial scar, but its limited accessibility motivates routine ECG-based screening. We evaluated whether $β$-variational autoencoder (VAE)-derived ECG representations can discriminate LGE+ from LGE- cardiomyopathic patients in a local cohort of 300 subjects. We compared 32-dimensional features from the foundation ECGx.AI model with those from a shallower $β$-VAE trained on normal PTB-XL ECGs, evaluating downstream classification and Dynamic Time Warping (DTW)-based reconstruction errors. ECGx.AI reached an area under ROC of 0.686 with Random Forest, while the proposed $β$-VAE reached 0.577 with sensitivity of 0.775 with Gradient Boosting. Notably, DTW-reconstruction errors significantly differed between classes in 10 out of 12 leads according to Mann-Whitney U test and help in classification, leading to an area under ROC of 0.643 with Logistic Regression, supporting their potential as markers of scar-related ECG alterations.

0.22

ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation

eess.IV cs.CVcs.LGphysics.med-ph ·2026-09-20 ·Omer Burak Demirel, Kelly K. Horst, Alessio Perazzolo, Elisa Bruno, Kenan Kaya +13 more
similarity 0.66
Abstract

Cardiovascular magnetic resonance (CMR) provides comprehensive cardiac assessment but remains underutilized because of the complexity of acquisition, post-processing, and interpretation. Existing artificial intelligence (AI) methods address isolated tasks, limiting clinical integration. We present ORION-CMR (On-scanner Reporting with Integrated fOunda-tioN Model), the first clinically evaluated scanner-native end-to-end CMR foundation model. Pretrained on 12,896,733 CMR images from 9,258 studies, ORION-CMR performs sequence classification, ventricular function assessment, late gadolinium enhancement (LGE) detection, binary and multiclass disease classification, and local large language model-based report generation in approximately 90 seconds. The framework. was evaluated on public benchmarks and clinically validated in a multi-vendor cohort of 68 subjects with normal examinations, congenital heart disease, dilated cardiomyopathy, and myocardial infarction. ORION-CMR outperformed supervised baselines and the previously published CMR foundation model (CMR-FM), achieving state-of-the-art performance for LGE classification and scar segmentation. Clinical evaluation achieved an AUC of 0.96 for normal-versus abnormal classification and 0.88 for multiclass disease classification, while generated reports demonstrated 81.4% agreement with expert interpretation. These results demonstrate the feasibility of real-time scanner-native AI-assisted CMR analysis and automated report generation.

0.15

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.66
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.32

Interpretable Stress Detection from ECG Signals Using Motif-Based Anomaly Analysis

eess.SP cs.LG ·2026-08-27 ·Zhanna Balyan, Sachin Kumar
similarity 0.63
Abstract

Stress detection using physiological signals has gained significant attention due to its impact on both physical and mental health. While existing approaches based on machine learning and deep learning achieve strong predictive performance, they often rely on black-box models and fail to capture individual variability in physiological responses. In this work, we propose an interpretable and personalized framework for stress detection using electrocardiogram (ECG) signals based on motif discovery and Matrix Profile analysis. Instead of training a classifier, the method learns subject-specific baseline cardiac behavior by extracting recurring heartbeat patterns (motifs) from ECG signals. Stress is then detected as a deviation from these baseline patterns using a distance-based anomaly score. Experiments are conducted on the WESAD dataset using a carefully designed train-validation-test protocol to ensure reliable evaluation. The results show that the proposed approach can effectively detect stress for several subjects while providing clear interpretability through direct comparison of ECG patterns. However, the performance varies across individuals due to differences in physiological responses, with some subjects exhibiting minimal morphological changes under stress. Additional analysis incorporating heart rate variability (HRV) features reveals that while HRV can improve performance in certain cases, its contribution is not consistent across all subjects. These findings highlight the importance of personalization and interpretability in physiological stress detection and demonstrate that motif-based approaches provide a meaningful alternative to black-box models, while also revealing inherent limitations due to inter-subject variability.

0.23

A Vision Transformer for ECG-Based Detection of Left Ventricular Systolic Dysfunction Across Multiple Clinical Sites

cs.CV cs.LG ·2026-08-12 ·Burcu Ozek, Aruna Mohan, David Vorchheimer, Daniel Weiss, Eyal Kedar +3 more
similarity 0.63
Abstract · 19 pages, 5 figures, 5 tables; includes supplementary material with 3 additional figures

Reduced left ventricular ejection fraction (LVEF) is frequently asymptomatic and often detected only after advanced heart failure develops. Electrocardiograms are recorded routinely yet underused for this condition, because reduced LVEF has no single diagnostic waveform. We trained an ensemble of vision transformers from scratch to detect reduced LVEF ($\leq$40%) from 12-lead ECGs, analyzing each heartbeat individually, using 10,142 patients across seven sites in three US health systems. In a held-out external cohort of 4,092 patients from three geographically independent US clinical sites at a real-world reduced-LVEF prevalence of 8.72%, the model achieved an AUROC of 0.88 (95% CI 0.86-0.89), sensitivity 81.2%, specificity 81.0%, and negative predictive value 97.8%. Sensitivity remained high across sex, race, ethnicity, and comorbidity subgroups, while specificity was lower in older patients and those with atrial fibrillation or cardiomyopathy. Beat-level attention maps provided interpretability into the model's predictions, showing consistent focus on the QRS complex rather than the P wave. These findings support the potential of routine ECGs as a scalable first-pass triage step to identify patients who should undergo echocardiography for reduced ejection fraction across diverse patient populations.

0.10

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.63
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.63
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17