CS Paper Radar

A Vision Transformer for ECG-Based Detection of Left Ventricular Systolic Dysfunction Across Multiple Clinical Sites

Burcu Ozek, Aruna Mohan, David Vorchheimer, Daniel Weiss, Eyal Kedar, Tamar Sobol, Or Zilbershot, Fatemeh Afghah

cs.CV cs.LG ·submitted 2026-08-12 13:36 UTC · v1

Abstract

Reduced left ventricular ejection fraction (LVEF) is frequently asymptomatic and often detected only after advanced heart failure develops. Electrocardiograms are recorded routinely yet underused for this condition, because reduced LVEF has no single diagnostic waveform. We trained an ensemble of vision transformers from scratch to detect reduced LVEF ($\leq$40%) from 12-lead ECGs, analyzing each heartbeat individually, using 10,142 patients across seven sites in three US health systems. In a held-out external cohort of 4,092 patients from three geographically independent US clinical sites at a real-world reduced-LVEF prevalence of 8.72%, the model achieved an AUROC of 0.88 (95% CI 0.86-0.89), sensitivity 81.2%, specificity 81.0%, and negative predictive value 97.8%. Sensitivity remained high across sex, race, ethnicity, and comorbidity subgroups, while specificity was lower in older patients and those with atrial fibrillation or cardiomyopathy. Beat-level attention maps provided interpretability into the model's predictions, showing consistent focus on the QRS complex rather than the P wave. These findings support the potential of routine ECGs as a scalable first-pass triage step to identify patients who should undergo echocardiography for reduced ejection fraction across diverse patient populations.

Comment
19 pages, 5 figures, 5 tables; includes supplementary material with 3 additional figures

Closest papers

Nearest neighbours by meaning across the whole index.

Learning from VAE Errors to support ECG-based Differential Diagnosis of Myocardial Scar

cs.LG stat.ML ·2026-09-04 ·Shayan Sharifi, Riccardo Treu, Ilaria Gandin, Federico Garoia, Marco Merlo +1 more
similarity 0.63
Abstract · Accepted at the PharML Workshop, ECML PKDD 2026

Late Gadolinium Enhancement (LGE) on cardiac magnetic resonance is a key marker of myocardial scar, but its limited accessibility motivates routine ECG-based screening. We evaluated whether $β$-variational autoencoder (VAE)-derived ECG representations can discriminate LGE+ from LGE- cardiomyopathic patients in a local cohort of 300 subjects. We compared 32-dimensional features from the foundation ECGx.AI model with those from a shallower $β$-VAE trained on normal PTB-XL ECGs, evaluating downstream classification and Dynamic Time Warping (DTW)-based reconstruction errors. ECGx.AI reached an area under ROC of 0.686 with Random Forest, while the proposed $β$-VAE reached 0.577 with sensitivity of 0.775 with Gradient Boosting. Notably, DTW-reconstruction errors significantly differed between classes in 10 out of 12 leads according to Mann-Whitney U test and help in classification, leading to an area under ROC of 0.643 with Logistic Regression, supporting their potential as markers of scar-related ECG alterations.

0.22

Cardiac MRI-informed electrocardiography enables biologically grounded cardiomyopathy detection

cs.AI q-bio.QM ·2026-11-18 ·Zhengyao Ding, Kewen Wang, Yujian Hu, Ziyu Li, Yiheng Mao +25 more
similarity 0.63
Abstract · 46 pages, 9 figures

Precise myocardial phenotyping at population scale is limited by the cost and accessibility of cardiac magnetic resonance (CMR), whereas electrocardiography (ECG) is widely available but reflects electrical rather than structural and functional information. Here we develop MyoECG, a cross-modal representation learning framework that distils myocardial structural and functional knowledge from CMR into standard 12-lead ECGs, enabling imaging-informed cardiomyopathy detection and subtype classification from ECGs alone. MyoECG was pretrained on 45,241 paired ECG-CMR examinations from UK Biobank and a tertiary cardiovascular centre, then developed and validated across more than 1.8 million ECGs from seven independent datasets. Across internal and external datasets spanning prevalences of 0.2-54.7%, MyoECG outperformed five pretrained ECG foundation models, with AUROCs of 0.800-0.974 for cardiomyopathy detection. In a multi-reader study of six cardiologists, MyoECG assistance improved mean sensitivity by 0.109 (95% CI, 0.041-0.175; P = 0.009) and specificity by 0.056 (95% CI, 0.004-0.108; P = 0.040). In 41,128 UK Biobank participants, the MyoECG score showed genetic correlations with cardiomyopathy (rg = 0.409) and dilated cardiomyopathy (rg = 0.371), genome-wide associations at four loci, including regions mapped to NFIA and KCNQ1, and associations with 69 circulating proteins related to myocardial stress, cell adhesion, vascular biology and metabolism. The cardiomyopathy correlation attenuated to non-significance after adjustment for 27 measured CMR traits (rg = 0.131; P = 0.143), indicating that the score captures CMR-derived information rather than dataset-specific shortcuts. MyoECG offers a scalable route to CMR-informed cardiomyopathy assessment and a strategy for transferring knowledge from resource-intensive imaging to widely deployable physiological signals.

0.15

Diagnosing as Cardiologists Do: ECG Agents with Doctor-Grounded Priors for Clinical Reasoning Across Diseases and Populations

eess.SP cs.CVcs.LG ·2026-08-10 ·Hongxiang Gao, He-yang Xu, Yuwen Li, Minghui Zhao, Zhipeng Cai +4 more
benchmark similarity 0.61
Abstract

Cardiologists interpret electrocardiograms by localizing waveform components, measuring rhythm and interval patterns, and translating these structured observations into diagnostic evidence. Whether this expert reading process can serve as an effective prior for ECG agents remains unclear. To address this question, we introduce LuminaECG, a clinically structured ECG reasoning framework that reformulates ECG interpretation as measurement-grounded visual reading. ECG signals are rendered on standard electrocardiographic grid paper to preserve the spatial and scale cues used in clinical reading. P-wave, QRS-complex, and T-wave boundaries are explicitly delineated, and color-coded segmentation decomposes the waveform into discrete visual measurement primitives. A general 2B vision-language backbone is then trained with low-rank supervised fine-tuning to associate these primitives with diagnostic reasoning, without architectural modification. Across open, proprietary, and ECG-specialist zero-shot baselines, LuminaECG improves both waveform measurement and diagnostic recovery. It reaches a clinically meaningful reader tier on the CODE-test benchmark, transfers across geographically diverse ECG datasets without retraining, and generates reports whose structure contains an emergent prognostic signal. These findings suggest that effective ECG agents require not only larger models, but supervision that preserves the alignment between measurable waveform evidence and clinical knowledge.

0.04

ECG-SDI: Single-lead Electrocardiogram Enables Continuous Sleep Depth Index Profiling and Scalable Digital Biomarkers for Sleep Health

eess.SP cs.LG ·2026-10-16 ·Donglin Xie, Qingshuo Zhao, Songchi Zhou, Haoyu Wang, Jingyu Wang +3 more
similarity 0.60
Abstract

Conventional sleep staging provides a coarse-grained representation that obscures within-stage depth variation. We developed ECG-SDI, a single-lead electrocardiography (ECG) framework for continuous sleep-depth profiling and digital biomarker extraction. Using 12,392 overnight polysomnographic recordings, we trained and validated a two-stage deep learning model supervised by conventional sleep-stage labels. Correlations with ordered stages excluding rapid eye movement (REM) sleep were 0.828 in the pooled internal test set and 0.848 in the external Cleveland Family Study; corresponding REM classification AUROCs were 0.954 and 0.977. Overnight trajectories captured within-stage variation. Biomarker-based phenotyping identified a disturbed subtype associated with poorer subjective sleep quality and higher all-cause mortality in the Sleep Heart Health Study (adjusted hazard ratio, 1.20; 95% CI, 1.05-1.38). Among 507 participants with paired recordings before and after continuous positive airway pressure (CPAP), normalized sleep-depth area increased by 6.1% and shallow-sleep burden below 0.3 decreased by 16.0%. Exploratory analyses linked reductions in approximate entropy and depth variability to reduced oxygen desaturation and increased sleep efficiency, respectively (Spearman rho = 0.24 and 0.12); both associations remained positive after covariate adjustment. Mean ECG-SDI within N2 increased by 0.017 (95% CI, 0.004-0.030). A wearable proof-of-concept illustrated the acquisition-to-report workflow. These findings support ECG-based sleep phenotyping and further evaluation of CPAP response monitoring at home.

0.13

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

eess.IV cs.AIcs.CV ·2026-11-13 ·João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós
published similarity 0.60
Abstract · 9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challeng…

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

0.37

ECG Mirage: Revealing and Mitigating the Underutilisation of ECGs in Vision-Language Models for Clinical Prediction

cs.AI ·2026-09-18 ·Jinning Liang, Mingcheng Zhu, Tingting Zhu
similarity 0.60
Abstract

Emergency department (ED) decision-making relies on heterogeneous clinical information, including patient history, vital signs, laboratory results, and electrocardiograms (ECGs). Vision--language models (VLMs) can jointly process these modalities, but strong predictive performance does not necessarily imply meaningful use of the correct patient's ECG. We term this failure mode ECG Mirage: apparent multimodal capability without useful dependence on patient-specific ECG information. We distinguish two forms: ECG neglect, where ECGs provide little predictive benefit, and ECG confusion, where matched ECGs outperform no-image inputs but not mismatched ECGs. To evaluate these behaviours, we compare predictions obtained with matched ECGs, outcome-discordant mismatched ECGs, and no-image inputs while holding the clinical text and prediction targets fixed. Across four VLMs on MDS-ED, matched ECGs provide no consistent advantage for either ICU admission or clinical deterioration prediction. We then train four restricted visual prompts using supervised learning followed by conditional direct preference optimisation, while keeping the VLM backbone frozen. The resulting models achieve balanced accuracies of 70.6% for ICU admission and 67.5% for deterioration and increase the matched-versus-mismatched performance gap to approximately 16.5 and 5.5 percentage points, respectively. Overall, our study identifies ECG Mirage in multimodal clinical prediction and introduces visual prompt tuning as an efficient mitigation strategy.

0.36

A Cardiorespiratory Foundation Model Pretrained on Ten Physiological Signals for Perioperative and Critical Care

cs.LG cs.AI ·2026-11-11 ·Cheol-Hui Lee, Wookyung Kim, Hyeonhoon Lee, Garam Lee, Da-in Eun +1 more
similarity 0.59
Abstract

Arterial, venous, pulmonary artery and intracranial pressures and ventilator waveforms guide decisions in operating rooms and intensive care units, yet foundation models for physiological waveforms have been built almost entirely on the electrocardiogram and photoplethysmogram. We present CARMEN, a single encoder pretrained without labels on ten cardiorespiratory waveforms (2.27 million modality-hours). CARMEN accepts any combination of co-recorded signals from 10 s to 5 min, and a conditioning mechanism, LSCNorm, restores the absolute signal level that normalization removes; without it, the AUROC for intraoperative hypotension fell from 0.894 to 0.780. Across 19 tasks from Korean and US cohorts, the frozen encoder outperformed supervised models on 12 of 15 and three foundation models, one general-purpose and two for biosignals, on 14 to 17 of 19, with none exceeding it on any task. Given the electrocardiogram or photoplethysmogram alone, it matched or exceeded signal-specific foundation models in most comparisons, and it retained its performance when channels were missing.

0.16

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.59
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17