CS Paper Radar

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós

eess.IV cs.AIcs.CV ·submitted 2026-11-13 17:19 UTC · v1
published

Abstract

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

Comment
9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challenges) proceedings. The accepted version includes methodological revisions and is available at https://papers.miccai.org/miccai-2026-sat/paper/EchoRisk2026_018.pdf

Closest papers

Nearest neighbours by meaning across the whole index.

A Unified DINOv2-Based Framework for LVEF Estimation, GLS Dysfunction Classification, and Early Cardiotoxicity Prediction

eess.IV cs.CV ·2026-08-14 ·Xiaotong Zhang, Mingyue Cui, Qing Cao, Jingming Xia
published similarity 0.78
Abstract · Accepted as an oral at the EchoRisk Challenge Workshop, MICCAI 2026

Left ventricular ejection fraction (LVEF) estimation (Task 1), global longitu-dinal strain (GLS)-based dysfunction classification (Task 2), and early cardi-otoxicity prediction (Task 3) provide complementary information for cardio-oncology assessment. LVEF reflects macroscopic ventricular volume chang-es as the clinical standard, whereas GLS captures subtle myocardial defor-mation, indicating subclinical cardiotoxicity before overt LVEF decline. Fur-thermore, predicting cardiotoxicity from baseline echocardiography prior to treatment enables preventive interventions at an early stage. To address these three tasks, we employ a DINOv2-based framework with task-specific adap-tation and prediction heads. Built upon a frozen foundation encoder, the framework incorporates parameter-efficient Low-Rank Adaptation (LoRA) and temporal aggregation to learn task-specialized representations, ensuring robust generalization. Crucially, during inference, it operates in a fully cycle-detection-free and phase-free manner, requiring neither cardiac cycle seg-mentation nor explicit End-Diastolic/End-Systolic (ED/ES) annotations. Ad-ditionally, we introduce an ED/ES-guided 2D/3D hybrid multi-view regres-sion model specifically to optimize Task 1. On a patient-level split containing 1,203 training videos from 237 patients and 300 validation videos from 59 independent patients, the DINOv2-based framework achieved a mean abso-lute error (MAE) of 5.03% for Task 1, an AUC-ROC of 76.48% for Task 2, and an AUC-ROC of 70.26% for Task 3. For Task 1, the specialized ED/ES-guided model further improves performance, achieving an MAE of 4.64%. This framework demonstrates the effectiveness of foundation model repre-sentations across diverse cardio-oncology tasks and the additional benefit of physiology-guided modeling for accurate LVEF estimation.

0.18

Domain adaptation of a video Foundation model for Heart Failure Diagnosis from Echocardiography

cs.CV ·2026-11-09 ·Mahyar Bolhassani, Tijana Geroski, Narayana S. Singam, Amir Amini
publishedcode/datahot direction similarity 0.73
Abstract · 6 pages, 6 figures, accepted and presented at Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC …

The rapid advancement of foundation models has transformed computer vision, yet their adaptation to medical imaging, particularly purpose built foundation models for spatio temporal echocardiography videos, remains limited. In this work, we explore the feasibility of fine tuning a pretrained foundation model for video (TimeSformer) for automated diagnosis of reduced ejection fraction heart failure (HFrEF) from apical four chamber videos. The model is finetuned on the publicly available RVENet A4C dataset with a phase aware clip generation strategy that captures complementary systolic and diastolic dynamics. We employ divided space time attention, layer wise learning rate decay, and multi clip inference to enhance robustness under limited data. Experimental results show that full fine tuning of the proposed model outperforms classifier only tuning and a 3D CNN baseline. These findings highlight the potential of leveraging foundation video models for echocardiography based heart failure diagnosis and motivates further domain adaptation studies in medical imaging.

0.41

Learning from Scarce Labels: Multi-View Echocardiography for Ejection Fraction Prediction

eess.IV cs.CVcs.LG ·2026-09-02 ·Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
top venuedatasetcode/data similarity 0.73
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:025

We present, to the best of our knowledge, the first publicly available resource for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography. Because no PLAX-EF datasets previously existed, our work focuses on an innovative data generation strategy to overcome this scarcity. By leveraging a time-based correlation between clinical notes and echocardiographic videos, combined with fine-tuning view classifiers and proxy labeling, we created a labeled dataset of over 25,000 PLAX videos. This enables us to train the first reproducible PLAX EF model, achieving a mean absolute error (MAE) of 6.86%. Given that apical four-chamber (A4C) methods, the clinical standard, report MAE values of 6%-7%, our results demonstrate that EF estimation from PLAX views is both feasible and clinically relevant. This surpasses the performance of existing methods and provides a clinically relevant solution for situations where apical views may not be feasible. Going further, we demonstrate that combining PLAX and A4C predictions via simple unweighted late fusion improves both single-view baselines to a 6.37% MAE, underscoring the value of multi-view integration. To promote continued research, we release the dataset labels, trained models, and runnable demos on GitHub, Hugging Face, and Google Colab: https://github.com/Jeffrey4899/PLAX_EF_Labels_202509

0.46

EchoTab: Learning Measurement-Grounded Representations for Echocardiographic Diagnosis through Tabular Reconstruction

cs.LG ·2026-10-09 ·Michelle Espranita Liman, Ioana Ionac, Alexander Müller, Eimo Martens, Daniel Rueckert +1 more
code/data similarity 0.68
Abstract

Diagnostic information in multi-view medical imaging studies, like echocardiography, is distributed across views, each capturing different aspects of cardiac structure and function. In clinical practice, these views are first interpreted through quantitative measurements, which then support specific diagnoses. However, existing echo representation learning methods do not explicitly model measurements as an intermediate representation between views and diagnosis. As a result, individual measurements are not explicitly represented in a form that downstream diagnostic tasks can selectively use, hindering accurate diagnosis. Inspired by this hierarchical clinical workflow, we introduce EchoTab, a measurement-grounded representation learning framework that represents multi-view echocardiography studies using measurement-specific tokens as an intermediate representation between echo views and diagnosis. Each measurement token selectively attends to the views relevant to its estimation and is trained through tabular reconstruction to predict the corresponding measurement value. The resulting tokens form a factorized echo representation, which encode clinically meaningful structural and functional properties and can be selectively used for downstream diagnosis. Unlike the commonly used contrastive approaches, EchoTab does not require negative samples or large batch sizes. Experiments on two datasets demonstrate that EchoTab learns effective measurement-grounded representations that improve diagnosis classification in multi-view echocardiography and its learned attention aligns with established measurement-view relationships used by cardiologists. Our code is accessible at https://github.com/michelleespranita/EchoTab.

0.44

MR-JEPA: A General Purpose Video Foundation Model for Cardiac MRI

cs.CV cs.AI ·2026-08-31 ·Athira J. Jacob, Puneet Sharma, Dorin Comaniciu, Daniel Rueckert
published similarity 0.68
Abstract · Accepted at STACOM 2026 (MICCAI 2026 peer-reviewed workshop)

Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep learning approaches process individual 2D slices, discarding this context. We present MR-JEPA, a self-supervised video foundation model for CMR that extends LeJEPA to 3D spatiotemporal inputs through tubelet tokenization, spatiotemporal masking augmentation, and initialization from a 2D CMR foundation model. Unlike prior CMR video models limited to cine data, MR-JEPA is pretrained on multi-sequence data (cine, LGE, mapping) from 10,505 patients across two centers without annotations. We evaluate the frozen encoder on six downstream tasks using a unified multi-view gated attention architecture: LV ejection fraction, RV ejection fraction, three myocardial strains (GLS, GCS, GRS), and four-class disease detection. MR-JEPA outperforms other compared methods on all five regression tasks, including both a domain-specific CMR model pretrained on more data with text supervision and a natural-video foundation model, achieving an LV EF MAE of 4.79% (r =0.764) and a GLS MAE of 1.87 (r=0.805), with 21-27% MAE reductions over baselines on strain tasks. For disease detection, MR-JEPA achieved a macro AUG of 0.868, remaining competitive with the domain-specific baseline despite using a fully self-supervised pretraining objective. These results demonstrate the potential of a unified video encoder for robust, multi-view utilization of diverse CMR sequences in clinical cardiac quantification and diagnosis.

0.31

X-LMC: Cross-View Spatiotemporal Collateral Circulation Scoring from DSA

cs.CV ·2026-08-19 ·Maedeh Hafezi Moghadas, Hakim Baazaoui, Lukas Bastian Otto, Susanne Wegener, Björn Menze +1 more
publishedcode/data similarity 0.67
Abstract · 11 pages, 3 figures, 1 table. Accepted at SWITCH+ 2026, a MICCAI 2026 workshop

Digital subtraction angiography (DSA) is the reference standard for leptomeningeal collateral (LMC) assessment, providing critical prognostic insights to guide secondary treatment strategies, neurorehabilitation planning, and retrospective stroke research. However, clinical LMC grading via the ASITN/SIR scale relies on manual, highly variable visual inspection. We introduce X-LMC, a spatiotemporal framework for automated collateral scoring from time-resolved biplane DSA. The proposed architecture encodes spatial frame representations through a DINOv2 backbone, fuses orthogonal projections via a token-level cross-view attention module, and models representations of contrast bolus dynamics using a recurrent network architecture. We evaluate our framework on a multicenter dataset of 134 patients with M1-segment occlusions. In a 5-fold cross-validation setting, X-LMC yields higher point estimates than static architectures and spatiotemporal baselines adapted from related angiographic tasks, achieving a Quadratic Weighted Kappa (QWK) of 0.398 (vs. 0.322) and a dichotomized macro-F1 score of 0.711 (vs. 0.663) against the best-performing baseline. X-LMC performance also aligns with the observed clinical inter-rater agreement (QWK: 0.314). As the first DSA study attempting to automate LMC scoring, we demonstrate that multi-view temporal deep learning can capture collateral-specific contrast kinetics. Ultimately, these benchmarks delineate the clinical ambiguities and achievable performance boundaries of automated ASITN/SIR grading, establishing a reproducible foundation for objective hemodynamic phenotyping in stroke cohorts. Code is available at https://github.com/maedehafezi/X-LMC.

0.45

Reading the Whole Heart: Latent-Attention Masked Autoencoders for Multimodal Cardiac Representation Learning

cs.AI ·2026-09-10 ·Andrea Agostini, Simon Böhi, Moritz Vandenhirtz, Samuel Ruiperez-Campillo, Max Krähenmann +5 more
similarity 0.66
Abstract

Cardiovascular diagnosis and treatment rest on integrating complementary modalities, such as electrocardiogram, echocardiography, and chest X-rays, each capturing distinct but complementary aspects of cardiac pathophysiology. Yet most medical foundation models remain modality-specific, combining modalities only for finetuning or post-training. This discards the cross-modal evidence clinicians naturally integrate and ignores the structure within each modality. We introduce Latent-Attention Masked Autoencoder (LAMAE), a multimodal, structure-aware masked autoencoder that jointly learns patient-level representations during self-supervised pretraining. Instead of fusing modalities post hoc, LAMAE exchanges information directly in the latent space through a shared latent-attention module operating over a study-view-entity hierarchy, enabling aggregation of variable observations and handling of missing modalities. Pretrained on over 500'000 MIMIC-IV hospital stays, LAMAE outperforms modality-specific pretraining and strong contrastive and vision-language baselines across multimodal hospital-stay tasks, such as in-hospital mortality, ICD-10 and DRG coding, and length of stay, while remaining competitive on unimodal tasks. Modeling this structure also pays off within a single modality: even without cross-modal information, the latent-attention module improves representations over modality-specific pretraining.

0.11

The segmentation ceiling: why explicit left-ventricular masks do not improve learned ejection-fraction regression

eess.IV cs.CV ·2026-09-17 ·Farshid Farhadi Khouzani, Paul La Plante, Bryar Mustafa Shareef, Laxmi Gewali
similarity 0.66
Abstract · 15 pages, 4 figures

Accurate estimation of left ventricular ejection fraction (EF) from echocardiography is central to cardiovascular care, and deep learning enables automated EF prediction from echocardiographic video. Because EF is clinically derived from left-ventricular (LV) volumes, a widely held intuition is that explicit LV segmentation should improve prediction. We introduce a quantitative criterion, the segmentation ceiling, that makes this testable: from EF as a normalized difference of end-diastolic and end-systolic volumes, we derive in closed form how per-frame segmentation area error propagates into EF error, and thus the accuracy a mask must reach before it can improve on direct regression. Using EchoNet-Dynamic, a UniFormer-S backbone, and the empirically measured within-patient error correlation, the criterion places the break-even near 10% per-frame area error, whereas a representative segmenter operates at roughly 14%, above the ceiling. Consistent with this, four strategies for injecting segmentation or area information (a predicted-mask channel, end-diastolic/end-systolic clip sampling, and per-bin and amplitude area-consistency objectives) fail to beat a raw-video baseline; ground-truth masks help only through label leakage. Input representation thus not being the limit, we identify generalization as the practical lever: weight averaging with strong augmentation attains a test R^2 of 0.806 (MAE 4.08) under a matched dense-clip protocol, comparable to an R(2+1)D baseline (0.811) while tightening the validation-to-test gap. Finally, a heteroscedastic beta-NLL formulation yields informative, well-calibrated per-prediction uncertainty, larger for clinically harder low-EF cases, where Monte-Carlo dropout does not. The segmentation ceiling gives a concrete design criterion for when mask-guided EF estimation is worthwhile, plus a simple, uncertainty-aware recipe for EF regression.

0.12