CS Paper Radar

X-LMC: Cross-View Spatiotemporal Collateral Circulation Scoring from DSA

Maedeh Hafezi Moghadas, Hakim Baazaoui, Lukas Bastian Otto, Susanne Wegener, Björn Menze, Ezequiel De la Rosa

cs.CV ·submitted 2026-08-19 14:51 UTC · v1
publishedcode/data

Abstract

Digital subtraction angiography (DSA) is the reference standard for leptomeningeal collateral (LMC) assessment, providing critical prognostic insights to guide secondary treatment strategies, neurorehabilitation planning, and retrospective stroke research. However, clinical LMC grading via the ASITN/SIR scale relies on manual, highly variable visual inspection. We introduce X-LMC, a spatiotemporal framework for automated collateral scoring from time-resolved biplane DSA. The proposed architecture encodes spatial frame representations through a DINOv2 backbone, fuses orthogonal projections via a token-level cross-view attention module, and models representations of contrast bolus dynamics using a recurrent network architecture. We evaluate our framework on a multicenter dataset of 134 patients with M1-segment occlusions. In a 5-fold cross-validation setting, X-LMC yields higher point estimates than static architectures and spatiotemporal baselines adapted from related angiographic tasks, achieving a Quadratic Weighted Kappa (QWK) of 0.398 (vs. 0.322) and a dichotomized macro-F1 score of 0.711 (vs. 0.663) against the best-performing baseline. X-LMC performance also aligns with the observed clinical inter-rater agreement (QWK: 0.314). As the first DSA study attempting to automate LMC scoring, we demonstrate that multi-view temporal deep learning can capture collateral-specific contrast kinetics. Ultimately, these benchmarks delineate the clinical ambiguities and achievable performance boundaries of automated ASITN/SIR grading, establishing a reproducible foundation for objective hemodynamic phenotyping in stroke cohorts. Code is available at https://github.com/maedehafezi/X-LMC.

Comment
11 pages, 3 figures, 1 table. Accepted at SWITCH+ 2026, a MICCAI 2026 workshop

Closest papers

Nearest neighbours by meaning across the whole index.

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

eess.IV cs.AIcs.CV ·2026-11-13 ·João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós
published similarity 0.67
Abstract · 9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challeng…

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

0.37

A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

cs.CV cs.AI ·2026-08-12 ·Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim +4 more
published similarity 0.67
Abstract · Acceteed by Medical Physics 2026

Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy. The LAD is extremely small, has poor soft-tissue contrast, and varies substantially across patients; even manual contours show limited inter-observer agreement, underscoring the ambiguity of the vessel boundaries. Purpose: To develop a transformer-based framework that improves LAD delineation in low-contrast, imbalanced CT through local-global context modeling and uncertainty-guided optimization. Methods: We propose NA-UNETR, a 3D transformer-based segmentation model whose Neighborhood Attention (NA) and Dilated NA (DiNA) blocks jointly capture fine structural detail and long-range context. Given the scarcity of annotated LAD data, the model is pretrained on 1,000 CTA volumes of general coronary anatomy and fine-tuned with LoRA-based parameter-efficient adaptation on 20 free-breathing institutional CT scans. A composite Dice-Focal and Hausdorff loss, dynamically balanced via homoscedastic uncertainty, improves overlap and boundary accuracy. Results: NA-UNETR reached 45.64% Dice, 38.16 mm HD95, and 10.01 mm ASD, improving Dice by 3.10 percentage points over nnU-Net and reducing HD95 by 2.96 mm relative to Swin UNETR, with the strongest boundary accuracy among all models and improved centerline stability. On ImageCAS it achieved 79.49% Dice, 8.89 mm HD95, and 1.02 mm ASD. Ablations confirmed that residual blocks, variable kernels, and uncertainty-weighted loss each contributed. Conclusions: NA-UNETR balances local precision and global context for thin, low-contrast LAD structures, offering a computationally efficient framework for substructure-level cardiac segmentation in radiotherapy planning.

0.52

Cross-Architectural Feature Fusion for Coronary Artery Stenosis Detection in X-ray Angiography

cs.CV ·2026-10-23 ·Haobo Zhu, Mojtaba Lashgari, Jason Chai, Giovanni Luigi De Maria, Vicente Grau +1 more
similarity 0.66
Abstract · 12 pages, 3 figures

Coronary artery disease remains a leading cause of mortality, with stenosis detection from invasive X-ray Coronary Angiography (XCA) critical for diagnosis. Manual interpretation is time-consuming, subjective, and variable, especially under low contrast and vessel overlap. Existing deep learning methods often rely solely on detection or segmentation, limiting performance. We propose a hybrid framework, Fusion-YOLOv11-L, combining a YOLOv11-L detector with a pretrained UNet++ via a channel attention gating module. This enables fusion of semantic and vessel-aware structural features, improving localisation of stenotic regions. The UNet++ is pretrained on ARCADE vessel segmentation dataset to provide anatomically informed representations. Experiments on the relabeled ARCADE (ARCADE*) dataset show improved performance over YOLOv11-L, achieving AP@50 of 0.585 and F1-score of 0.596. Cross-domain evaluation on a dataset from the Oxford Acute Myocardial Infarction (OxAMI) Study reveals performance degradation due to domain shift, mitigated using test-time adaptation and augmentation. Test-time augmentation improves AP@50 from 0.434 to 0.480, indicating better generalisability. These results show that cross-architecture feature fusion and lightweight adaptation improve robustness and generalisability of automated stenosis detection in XCA.

0.27

Scribble Once, Segment the Sequence: Bidirectional Temporal Consistency for Weakly Supervised Segmentation in Echocardiography Sequences

eess.IV cs.CV ·2026-11-16 ·Vincent Li Weixin, Chen Jingkun, Vicente Grau
similarity 0.66
Abstract

Temporal medical image segmentation relies on pixel-wise annotations, which are prohibitively expensive for long image sequences. Existing weakly-supervised methods reduce the annotation burden per frame but still require repeated annotations across the sequence. Furthermore, sparse supervision can result in temporally unstable representations. Addressing both challenges requires a model that can leverage strong spatial priors from large-scale pretraining while minimizing reliance on dense annotations. Frozen 2D vision foundation models provide a promising basis for this by offering transferable spatial representations with low trainable parameters. However, their lack of explicit temporal modeling limits their ability to propagate reliable information across anatomical sequences. To address this, we present a weakly-supervised framework for temporal segmentation from a single scribble-annotated frame, with all remaining frames left unlabeled. The framework combines parameter-efficient adaptation of DINOv3 encoders present in the mean-teacher architecture. Furthermore, a set of complementary losses, including a temporal loss helps generate reliable segmentation priors for the unlabeled frames. This formulation decouples annotation costs from sequence length while retaining the transferable spatial knowledge of the pretrained encoder. Extensive experiments on the publicly available CAMUS and CardiacNet datasets demonstrate that our approach outperforms other scribble-supervised methods. These results show that accurate and temporally consistent segmentation can be achieved from extremely sparse supervision, substantially reducing annotation requirements for temporal echocardiographic segmentation and providing a practical framework for scalable clinical deployment.

0.16

CAST: Calibrating Correspondences for Training-Free Biomedical In-Context Segmentation

cs.CV ·2026-11-17 ·Mingze Jiang, Jiashu Han, Haonan Chen, Zhiyi Li, Yilun Du +1 more
similarity 0.66
Abstract · 10 pages, 6 figures

Biomedical image segmentation must keep up with new anatomical structures, subjects, imaging modalities, and acquisition protocols, yet dense expert annotations are scarce and models trained on one cohort often struggle to transfer. In-context segmentation (ICS) offers a way out: a new structure is specified by a few annotated exemplars at inference time. However, reliable correspondence remains challenging in biomedical images, where adjacent structures often share similar appearances, and variations across subjects and imaging conditions further obscure their distinctions. We introduce CAST, a training-free framework built on a frozen DINOv3 backbone to calibrate fine-grained correspondences. Its stability test improves feature reliability at both global and patch-specific levels, while its coherence test assesses whether candidate correspondences are supported by consistent local structural context. Together, these tests enable more reliable correspondence across diverse anatomical structures and imaging conditions. Across eight biomedical benchmarks spanning 2D and 3D segmentation, cross-subject, and cross-modality transfer, CAST outperforms the strongest overall baseline by 12.34 percentage points in Dice and ranks first across all six volumetric settings. The versatility of CAST further opens up opportunities for challenging biomedical applications, including 2D-to-3D segmentation and atlas label transfer.

0.23

Temporal Diffusion Bridge Model for Vessel Extraction Using Physics-informed Synthetic Data

eess.IV cs.CV ·2026-10-08 ·Jinkui Hao, Donald R. Cantrell, Ramez Abdalla, Sameer A. Ansari, Bo Zhou
code/data similarity 0.65
Abstract · 13 pages, 6 figures. Under review at Medical Image Analysis

Accurate artery extraction from X-ray coronary angiography (XCA) is essential for coronary artery disease diagnosis and intervention. However, low vessel visibility, respiratory and cardiac motion, and limited annotations challenge existing methods. Moreover, most deep learning approaches produce binary vessel masks without preserving clinically relevant intra-arterial contrast information. We propose a Temporal Diffusion Bridge Model (TDBM) that formulates vessel extraction as image translation and learns from physics-informed synthetic data without manual vessel annotations. A physics-based XCA synthesis engine generates diverse, perfectly aligned pairs of contrast-enhanced and contrast-free images. Using these pairs, TDBM learns cross-domain mappings to recover high-fidelity vessel information. Temporal conditioning incorporates adjacent frames to improve consistency, while a vessel-aware contrastive loss exploits background-invariant synthetic pairs to enhance vascular discrimination. We evaluate TDBM on two XCA vessel segmentation datasets and conduct a reader study using two real-patient XCA sequence datasets. Zero-shot segmentation is further assessed on retinal imaging and fluorescence microscopy datasets. Results demonstrate that TDBM consistently outperforms existing methods and generalizes effectively across imaging modalities. Code and trained weights will be available at: https://github.com/Advanced-AI-in-Medicine-and-Physics-Lab/TDBM

0.21

X-Strata: Separating Aneurysms and Overlapping Vessels into Layers from 2D X-ray Angiography

eess.IV cs.CV ·2026-11-13 ·Zhihong Wen, Congzhou Chen, Hucheng Li, Xun Han, Jianning Zhang +7 more
similarity 0.65
Abstract · 22 pages, including 10 pages of supplementary material

An X-ray angiogram sums every structure along a ray into one pixel. When vessels cross an aneurysm, they obscure part of it and mix their contrast into its filling curve. We present X-Strata, a network that separates a cine angiogram into three layers: the complete aneurysm sac, the vessels in front of it, and the vessels behind it. Contrast timing indicates how much each layer contributes to a pixel, and parallax between two views indicates their order, which a single view cannot determine. X-Strata first estimates the layers and their contrast curves, then uses the second view to assign vessels to the front or back layer, and lifts all layers into 3D. It learns from layer labels projected from same-session 3D rotational angiography, but needs only 2D cine runs and their acquisition geometry at inference. On 220 held-out patients from three centers (122 external), two-view X-Strata ranks first among 14 baselines, including VGGT and C$^2$RV, in recovering the sac where vessels overlap it (Dice 0.693 internal, 0.641 external) and in ordering the layers (balanced accuracy 0.703, 0.659). Its order accuracy exceeds that of all 11 end-to-end baselines by at least 4.1 points internally and 3.3 externally (Holm-adjusted $p < 0.001$) and grows with view separation. Recovered 3D sac surfaces have a median Chamfer distance of 0.34 mm on the internal cohort. X-Strata may therefore provide layered aneurysm and vessel information, including 3D sac shape, for patients who undergo only 2D angiography.

0.20

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.65
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32