CS Paper Radar

Scribble Once, Segment the Sequence: Bidirectional Temporal Consistency for Weakly Supervised Segmentation in Echocardiography Sequences

Vincent Li Weixin, Chen Jingkun, Vicente Grau

eess.IV cs.CV ·submitted 2026-11-16 14:12 UTC · v1

Abstract

Temporal medical image segmentation relies on pixel-wise annotations, which are prohibitively expensive for long image sequences. Existing weakly-supervised methods reduce the annotation burden per frame but still require repeated annotations across the sequence. Furthermore, sparse supervision can result in temporally unstable representations. Addressing both challenges requires a model that can leverage strong spatial priors from large-scale pretraining while minimizing reliance on dense annotations. Frozen 2D vision foundation models provide a promising basis for this by offering transferable spatial representations with low trainable parameters. However, their lack of explicit temporal modeling limits their ability to propagate reliable information across anatomical sequences. To address this, we present a weakly-supervised framework for temporal segmentation from a single scribble-annotated frame, with all remaining frames left unlabeled. The framework combines parameter-efficient adaptation of DINOv3 encoders present in the mean-teacher architecture. Furthermore, a set of complementary losses, including a temporal loss helps generate reliable segmentation priors for the unlabeled frames. This formulation decouples annotation costs from sequence length while retaining the transferable spatial knowledge of the pretrained encoder. Extensive experiments on the publicly available CAMUS and CardiacNet datasets demonstrate that our approach outperforms other scribble-supervised methods. These results show that accurate and temporally consistent segmentation can be achieved from extremely sparse supervision, substantially reducing annotation requirements for temporal echocardiographic segmentation and providing a practical framework for scalable clinical deployment.

Closest papers

Nearest neighbours by meaning across the whole index.

A Quantitative Evaluation Framework for Temporal Explainability in Echocardiographic Video Segmentation

cs.CV cs.LG ·2026-09-07 ·Jiyoo Noh, Jonathan H. Chan
similarity 0.73
Abstract · 15 pages, 5 figures

Deep learning has achieved state-of-the-art performance in echocardiographic video segmentation, with an increasing number of models incorporating temporal information. However, quantitative evaluation of temporal explainability remains largely unexplored. We propose a quantitative framework for evaluating Grad-CAM explanations using four complementary metrics measuring temporal consistency, saliency motion, anatomical overlap, and temporal overlap. Using EchoNet-Dynamic, we compare a baseline 2D U-Net with ConvLSTM U-Net models trained across multiple temporal strides. While segmentation performance remained comparable across all models, intermediate ConvLSTM explanations exhibited substantially lower saliency consistency and greater centroid motion than final prediction explanations. Temporal Bottleneck explanations were significantly more stable than Encoder Bottleneck explanations across all strides, while final ConvLSTM Decoder3 explanations were broadly comparable to those of the 2D U-Net. Importantly, conventional frame-wise explanation metrics cannot determine whether variation in intermediate explanations reflects meaningful temporal feature evolution or explanation instability. These findings establish a preliminary quantitative framework for temporal explainability and motivate temporal-aware XAI methods that explicitly account for evolving representations in medical video models.

0.23

EchoDino: A pediatric foundation model for transferable echocardiographic analysis across the lifespan

cs.CV ·2026-10-04 ·Sheng Cheng, Donnchadh M. O'Sullivan, Daniel J. Penny, Craig G. Rusin, Minh B. Nguyen +1 more
similarity 0.73
Abstract · 33 pages, 5 figures, including Supplementary Information

Echocardiography is the most widely used cardiac imaging modality, yet interpretation demands integrating visual evidence across global anatomy, localized structures and dynamic cardiac motion. Machine-learning models have automated individual tasks, but they are typically built for a single purpose and depend on expensively labeled datasets - a barrier particularly acute in pediatric care, where data are scarce and anatomy changes with age. Here we present EchoDino, a self-supervised foundation model for echocardiography, created by adapting the DINOv3 framework to 3.7 million frames from 1.7 million unlabeled pediatric echocardiography videos. With its encoder frozen, EchoDino produces representations that capture global context, local anatomy, and dense spatial detail. We introduce Motion-biased Entropy Maximization Sampling (MEMS) to select the most informative frames for video-level analysis. Across nine pediatric and adult datasets, EchoDino outperformed strong baseline models, raising view-classification accuracy from 0.609 to 0.889 and the area under the receiver operating characteristic curve for structural-heart-disease detection from 0.811 to 0.872, while also cutting age-estimation error from 3.857 to 1.389 years, achieving the best segmentation accuracy and lowering ejection-fraction errors. By generalizing from label-free pediatric data to adult echocardiography, EchoDino offers a versatile foundation for cardiac image analysis across the lifespan.

0.19

Prompt2Echo (P2Echo): Text-Prompted Multi-View Echocardiography Segmentation with One Model

cs.CV ·2026-11-10 ·Moein Heidari, Alvin Kimbowa, Mahdi Tabatabaei, Afshin Bozorgpour, Sina Ghorbani Kolahi +6 more
code/data similarity 0.69
Abstract · 10 pages, 5 figures, 7 tables

Automated segmentation in multi-view echocardiography is essential for comprehensive cardiac assessment, yet remains challenging due to substantial anatomical and appearance variability across standard acoustic windows. In this paper, we present P2Echo, a unified framework capable of segmenting diverse cardiac structures across multiple standard echocardiographic views using a single model controlled by structured view-aware text prompts. Unlike recent foundation model adaptations that rely on implicit latent priors, P2Echo explicitly conditions the segmentation process via a novel Dynamic Image-Text Alignment (DyITA) module. DyITA integrates a differentiable routing mechanism and token differential operators to dynamically modulate decoder features according to the requested view and target structure. This allows the network to adaptively switch its processing pathways for different views without architectural changes. Extensive experiments on a large-scale internal dataset (seen during training) and held-out evaluation on three external datasets demonstrate that P2Echo matches or exceeds both view-specific specialists and state-of-the-art universal models at a fraction of their computational cost, offering an efficient, controllable solution for multi-plane cardiac analysis. Code is available at: https://github.com/moeinheidari7829/P2Echo.

0.56

MR-JEPA: A General Purpose Video Foundation Model for Cardiac MRI

cs.CV cs.AI ·2026-08-31 ·Athira J. Jacob, Puneet Sharma, Dorin Comaniciu, Daniel Rueckert
published similarity 0.68
Abstract · Accepted at STACOM 2026 (MICCAI 2026 peer-reviewed workshop)

Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep learning approaches process individual 2D slices, discarding this context. We present MR-JEPA, a self-supervised video foundation model for CMR that extends LeJEPA to 3D spatiotemporal inputs through tubelet tokenization, spatiotemporal masking augmentation, and initialization from a 2D CMR foundation model. Unlike prior CMR video models limited to cine data, MR-JEPA is pretrained on multi-sequence data (cine, LGE, mapping) from 10,505 patients across two centers without annotations. We evaluate the frozen encoder on six downstream tasks using a unified multi-view gated attention architecture: LV ejection fraction, RV ejection fraction, three myocardial strains (GLS, GCS, GRS), and four-class disease detection. MR-JEPA outperforms other compared methods on all five regression tasks, including both a domain-specific CMR model pretrained on more data with text supervision and a natural-video foundation model, achieving an LV EF MAE of 4.79% (r =0.764) and a GLS MAE of 1.87 (r=0.805), with 21-27% MAE reductions over baselines on strain tasks. For disease detection, MR-JEPA achieved a macro AUG of 0.868, remaining competitive with the domain-specific baseline despite using a fully self-supervised pretraining objective. These results demonstrate the potential of a unified video encoder for robust, multi-view utilization of diverse CMR sequences in clinical cardiac quantification and diagnosis.

0.31

A General-Purpose Dual-Path Interaction Framework for Multi-View Medical Image Segmentation: Alleviating Data Volume Dependency in Small-Sample Regimes

cs.CV ·2026-10-22 ·Shuhuan Wang, Yuanyuan Cui, Pengju Wang, Huimin Guo, Ling Yue +8 more
similarity 0.67
Abstract · 20 pages, 5 figures

The performance of medical image segmentation depends on a large amount of annotated data, and most segmentation models experience a significant drop in performance in low-sample-size scenarios. Existing semi-supervised and weakly supervised methods rely on specific network architectures, while traditional multi-view-assisted segmentation methods require strictly paired samples, which limits their clinical applications. To address these issues, we propose DPIF, a general-purpose plug-and-play dual-path interaction framework compatible with arbitrary encoder-decoder segmentation networks, which leverages cross-view anatomical complementarity to reduce annotation reliance. DPIF first performs Sinkhorn optimal transport-based cross-view distribution alignment to establish global semantic correspondence without sample-level pairing. It then adopts conditional mutual information-guided feature decoupling to enable bidirectional knowledge transfer only within the shared semantic space, suppressing view-specific noise. Finally, persistent homology-based topological regularization encodes anatomical invariants as unsupervised priors to mitigate overfitting. Experiments were conducted using 24 baseline models on a private multicenter echocardiography dataset and two public datasets. The results show that DPIF-enhanced models outperform single-view baseline models when trained on comparable amounts of data. Notably, most dual-path variants trained on 40\% - 60\% of the data achieve performance comparable to that of single-view models trained on the full dataset. This demonstrates that DPIF provides a general-purpose and scalable solution for data-scarce multi-view medical image segmentation problems.

0.26

EchoDiST: Self-distillation-based joint learning for diffusion-conditioned echocardiographic myocardial motion estimation

cs.CV ·2026-10-08 ·Feiyue Qi, Xingyue Wei, Jianwen Luo
similarity 0.66
Abstract · 19 pages, 14 figures

Motion estimation in echocardiography is essential for quantitative assessment of cardiac function and myocardial mechanics, but remains challenging due to image artifacts, limited image information, speckle decorrelation, and the scarcity of ground-truth displacement fields. Anatomy-guided approaches can provide structural information, yet often rely on expert-labeled myocardial segmentations. We propose EchoDiST, a framework for unsupervised echocardiographic myocardial motion estimation that integrates self-distillation-based joint learning with a diffusion-conditioned motion estimation network. Here, unsupervised motion estimation refers to learning without ground-truth displacement fields. The self-distillation strategy jointly optimizes anatomical segmentation and myocardial motion estimation under limited anatomical annotations. Diffusion-based conditioning is used during training with stochastic perturbations, while inference requires only a single deterministic forward pass without iterative reverse-diffusion sampling. EchoDiST was evaluated on three echocardiographic datasets, including two external test datasets under cross-view and cross-dataset settings. Compared with seven representative learning-based methods, EchoDiST consistently improved anatomical alignment, myocardial strain assessment, and motion-derived functional and cardiac-phase assessment. These gains were statistically significant across the evaluated tasks and datasets. Overall, EchoDiST provides an effective approach for reliable myocardial motion estimation under limited anatomical supervision and supports downstream quantitative assessment of cardiac function.

0.21

X-LMC: Cross-View Spatiotemporal Collateral Circulation Scoring from DSA

cs.CV ·2026-08-19 ·Maedeh Hafezi Moghadas, Hakim Baazaoui, Lukas Bastian Otto, Susanne Wegener, Björn Menze +1 more
publishedcode/data similarity 0.66
Abstract · 11 pages, 3 figures, 1 table. Accepted at SWITCH+ 2026, a MICCAI 2026 workshop

Digital subtraction angiography (DSA) is the reference standard for leptomeningeal collateral (LMC) assessment, providing critical prognostic insights to guide secondary treatment strategies, neurorehabilitation planning, and retrospective stroke research. However, clinical LMC grading via the ASITN/SIR scale relies on manual, highly variable visual inspection. We introduce X-LMC, a spatiotemporal framework for automated collateral scoring from time-resolved biplane DSA. The proposed architecture encodes spatial frame representations through a DINOv2 backbone, fuses orthogonal projections via a token-level cross-view attention module, and models representations of contrast bolus dynamics using a recurrent network architecture. We evaluate our framework on a multicenter dataset of 134 patients with M1-segment occlusions. In a 5-fold cross-validation setting, X-LMC yields higher point estimates than static architectures and spatiotemporal baselines adapted from related angiographic tasks, achieving a Quadratic Weighted Kappa (QWK) of 0.398 (vs. 0.322) and a dichotomized macro-F1 score of 0.711 (vs. 0.663) against the best-performing baseline. X-LMC performance also aligns with the observed clinical inter-rater agreement (QWK: 0.314). As the first DSA study attempting to automate LMC scoring, we demonstrate that multi-view temporal deep learning can capture collateral-specific contrast kinetics. Ultimately, these benchmarks delineate the clinical ambiguities and achievable performance boundaries of automated ASITN/SIR grading, establishing a reproducible foundation for objective hemodynamic phenotyping in stroke cohorts. Code is available at https://github.com/maedehafezi/X-LMC.

0.45

Optimal Transport Metric Learning for Feature Alignment in Partially Supervised Segmentation

eess.IV cs.AI ·2026-09-15 ·Dakini Mallam Garba, Salim Abdou Daoura
similarity 0.66
Abstract

Multi-organ segmentation is often challenged by partially annotated datasets and domain shifts across different imaging sources. To address these limitations, we propose a two-stage learning framework that efficiently leverages partial supervision. In the first stage, the model learns from available annotations to produce accurate segmentations of annotated organs, establishing robust feature representations. In the second stage, we introduce learnable organ prototypes and a Sinkhorn-triplet loss to enforce organ-wise feature consistency across datasets. This encourages latent embeddings of the same organ to remain close, while increasing separation between different organs, even when annotations are missing. Our approach achieves performance comparable to state-of-the-art methods on the BTCV dataset, while remaining computationally efficient. By explicitly aligning feature distributions rather than relying solely on pseudo-labels, the framework effectively mitigates domain shift, making it particularly suitable for medical image segmentation tasks with limited annotation resources.

0.06