CS Paper Radar

Prompt2Echo (P2Echo): Text-Prompted Multi-View Echocardiography Segmentation with One Model

Moein Heidari, Alvin Kimbowa, Mahdi Tabatabaei, Afshin Bozorgpour, Sina Ghorbani Kolahi, River Jiang, Wenjin Chen, David J. Foran, Jasmine Grewal, Dorit Merhof, Ilker Hacihaliloglu

cs.CV ·submitted 2026-11-10 01:08 UTC · v1
code/data

Abstract

Automated segmentation in multi-view echocardiography is essential for comprehensive cardiac assessment, yet remains challenging due to substantial anatomical and appearance variability across standard acoustic windows. In this paper, we present P2Echo, a unified framework capable of segmenting diverse cardiac structures across multiple standard echocardiographic views using a single model controlled by structured view-aware text prompts. Unlike recent foundation model adaptations that rely on implicit latent priors, P2Echo explicitly conditions the segmentation process via a novel Dynamic Image-Text Alignment (DyITA) module. DyITA integrates a differentiable routing mechanism and token differential operators to dynamically modulate decoder features according to the requested view and target structure. This allows the network to adaptively switch its processing pathways for different views without architectural changes. Extensive experiments on a large-scale internal dataset (seen during training) and held-out evaluation on three external datasets demonstrate that P2Echo matches or exceeds both view-specific specialists and state-of-the-art universal models at a fraction of their computational cost, offering an efficient, controllable solution for multi-plane cardiac analysis. Code is available at: https://github.com/moeinheidari7829/P2Echo.

Comment
10 pages, 5 figures, 7 tables

Closest papers

Nearest neighbours by meaning across the whole index.

AI-Based Multi-View Echocardiographic Image Synthesis using Dynamic Shape Control

cs.CV cs.AI ·2026-11-13 ·João Freitas, Anca Balinisteanu, Ahmed Youssef, Vitor Hugo Pereira, Jan D'hooge +1 more
published similarity 0.71
Abstract · 5 pages, 2 figures, accepted for publication in the Proceedings of the 2026 IEEE International Ultrasonics Symposium (IUS 2026)

Although automated methods have improved echocardiographic workflows, progress remains constrained by the need for large, well-annotated datasets. As the development of clinical databases is often limited by ethical and logistical challenges, synthetic data generation has emerged as a promising alternative. However, existing approaches commonly rely on left ventricle shape-based supervision or are tailored to specific cardiac views, limiting the generation of additional standard and unconventional imaging planes and the preservation of multi-view consistency across cardiac chambers. To address these limitations, we propose a novel framework for shape-controlled synthesis of multi-view echocardiographic sequences. First, multi-view cross-sections are extracted from dynamic whole-heart meshes. Ultrasound-like appearance is then introduced through a two-stage AI-based pipeline. In Stage 1, an unpaired GAN-diffusion model translates these cross-sections into realistic echocardiographic frames. As this translation is performed independently at the frame level, Stage 2 employs masked video reconstruction to improve temporal coherence and cardiac motion. Evaluation demonstrated high frame-level realism for both stages, while the integration of Stage 2 substantially improved video-level motion quality and temporal consistency. Overall, the proposed framework enables the generation of realistic multi-view echocardiographic sequences from diverse cardiac models, providing a scalable source of annotated data for dataset augmentation and the development of multi-view cardiac assessment methods.

0.33

Scribble Once, Segment the Sequence: Bidirectional Temporal Consistency for Weakly Supervised Segmentation in Echocardiography Sequences

eess.IV cs.CV ·2026-11-16 ·Vincent Li Weixin, Chen Jingkun, Vicente Grau
similarity 0.69
Abstract

Temporal medical image segmentation relies on pixel-wise annotations, which are prohibitively expensive for long image sequences. Existing weakly-supervised methods reduce the annotation burden per frame but still require repeated annotations across the sequence. Furthermore, sparse supervision can result in temporally unstable representations. Addressing both challenges requires a model that can leverage strong spatial priors from large-scale pretraining while minimizing reliance on dense annotations. Frozen 2D vision foundation models provide a promising basis for this by offering transferable spatial representations with low trainable parameters. However, their lack of explicit temporal modeling limits their ability to propagate reliable information across anatomical sequences. To address this, we present a weakly-supervised framework for temporal segmentation from a single scribble-annotated frame, with all remaining frames left unlabeled. The framework combines parameter-efficient adaptation of DINOv3 encoders present in the mean-teacher architecture. Furthermore, a set of complementary losses, including a temporal loss helps generate reliable segmentation priors for the unlabeled frames. This formulation decouples annotation costs from sequence length while retaining the transferable spatial knowledge of the pretrained encoder. Extensive experiments on the publicly available CAMUS and CardiacNet datasets demonstrate that our approach outperforms other scribble-supervised methods. These results show that accurate and temporally consistent segmentation can be achieved from extremely sparse supervision, substantially reducing annotation requirements for temporal echocardiographic segmentation and providing a practical framework for scalable clinical deployment.

0.16

EchoDino: A pediatric foundation model for transferable echocardiographic analysis across the lifespan

cs.CV ·2026-10-04 ·Sheng Cheng, Donnchadh M. O'Sullivan, Daniel J. Penny, Craig G. Rusin, Minh B. Nguyen +1 more
similarity 0.66
Abstract · 33 pages, 5 figures, including Supplementary Information

Echocardiography is the most widely used cardiac imaging modality, yet interpretation demands integrating visual evidence across global anatomy, localized structures and dynamic cardiac motion. Machine-learning models have automated individual tasks, but they are typically built for a single purpose and depend on expensively labeled datasets - a barrier particularly acute in pediatric care, where data are scarce and anatomy changes with age. Here we present EchoDino, a self-supervised foundation model for echocardiography, created by adapting the DINOv3 framework to 3.7 million frames from 1.7 million unlabeled pediatric echocardiography videos. With its encoder frozen, EchoDino produces representations that capture global context, local anatomy, and dense spatial detail. We introduce Motion-biased Entropy Maximization Sampling (MEMS) to select the most informative frames for video-level analysis. Across nine pediatric and adult datasets, EchoDino outperformed strong baseline models, raising view-classification accuracy from 0.609 to 0.889 and the area under the receiver operating characteristic curve for structural-heart-disease detection from 0.811 to 0.872, while also cutting age-estimation error from 3.857 to 1.389 years, achieving the best segmentation accuracy and lowering ejection-fraction errors. By generalizing from label-free pediatric data to adult echocardiography, EchoDino offers a versatile foundation for cardiac image analysis across the lifespan.

0.19

EchoDiST: Self-distillation-based joint learning for diffusion-conditioned echocardiographic myocardial motion estimation

cs.CV ·2026-10-08 ·Feiyue Qi, Xingyue Wei, Jianwen Luo
similarity 0.66
Abstract · 19 pages, 14 figures

Motion estimation in echocardiography is essential for quantitative assessment of cardiac function and myocardial mechanics, but remains challenging due to image artifacts, limited image information, speckle decorrelation, and the scarcity of ground-truth displacement fields. Anatomy-guided approaches can provide structural information, yet often rely on expert-labeled myocardial segmentations. We propose EchoDiST, a framework for unsupervised echocardiographic myocardial motion estimation that integrates self-distillation-based joint learning with a diffusion-conditioned motion estimation network. Here, unsupervised motion estimation refers to learning without ground-truth displacement fields. The self-distillation strategy jointly optimizes anatomical segmentation and myocardial motion estimation under limited anatomical annotations. Diffusion-based conditioning is used during training with stochastic perturbations, while inference requires only a single deterministic forward pass without iterative reverse-diffusion sampling. EchoDiST was evaluated on three echocardiographic datasets, including two external test datasets under cross-view and cross-dataset settings. Compared with seven representative learning-based methods, EchoDiST consistently improved anatomical alignment, myocardial strain assessment, and motion-derived functional and cardiac-phase assessment. These gains were statistically significant across the evaluated tasks and datasets. Overall, EchoDiST provides an effective approach for reliable myocardial motion estimation under limited anatomical supervision and supports downstream quantitative assessment of cardiac function.

0.21

A Quantitative Evaluation Framework for Temporal Explainability in Echocardiographic Video Segmentation

cs.CV cs.LG ·2026-09-07 ·Jiyoo Noh, Jonathan H. Chan
similarity 0.66
Abstract · 15 pages, 5 figures

Deep learning has achieved state-of-the-art performance in echocardiographic video segmentation, with an increasing number of models incorporating temporal information. However, quantitative evaluation of temporal explainability remains largely unexplored. We propose a quantitative framework for evaluating Grad-CAM explanations using four complementary metrics measuring temporal consistency, saliency motion, anatomical overlap, and temporal overlap. Using EchoNet-Dynamic, we compare a baseline 2D U-Net with ConvLSTM U-Net models trained across multiple temporal strides. While segmentation performance remained comparable across all models, intermediate ConvLSTM explanations exhibited substantially lower saliency consistency and greater centroid motion than final prediction explanations. Temporal Bottleneck explanations were significantly more stable than Encoder Bottleneck explanations across all strides, while final ConvLSTM Decoder3 explanations were broadly comparable to those of the 2D U-Net. Importantly, conventional frame-wise explanation metrics cannot determine whether variation in intermediate explanations reflects meaningful temporal feature evolution or explanation instability. These findings establish a preliminary quantitative framework for temporal explainability and motivate temporal-aware XAI methods that explicitly account for evolving representations in medical video models.

0.23

Multimodal Generative AI Assists Comprehensive Echocardiographic Interpretation

cs.CV ·2026-10-23 ·Yi Qin, Marawan Elbatel, Shanshan Song, Taoran Huang, Jiarong Guo +26 more
similarity 0.65
Abstract

Echocardiography is the cornerstone of cardiovascular diagnostics, yet its global utility is constrained by a critical shortage of experienced interpreters. Current artificial intelligence (AI) solutions remain limited, typically operating as opaque "black boxes" or focusing on narrow tasks that fail to capture the holistic, guideline-driven reasoning of a clinician. Here we introduce EchoChat, a generative multimodal vision-language model that performs comprehensive echocardiographic analysis to support clinician interpretation. By emulating the cognitive workflow of a cardiologist, EchoChat integrates vast medical knowledge with a chain-of-thought reasoning mechanism to explicitly ground its conclusions in visual evidence. Trained on echocardiography-instruction pairs from 46,358 examinations, our model establishes a new state-of-the-art across diverse cohorts from six international medical centers. It supports the broadest diagnostic scope of 33 cardiac conditions and findings, including 15 newly added conditions for which it achieves an average F1 of 73.7% across available external evaluations. It surpasses existing best-performing foundation models in cardiac condition recognition (improving average recall by 13.54% on shared tasks) and quantification (average R2 score increase of 0.275 on shared tasks). Furthermore, in a source-blinded echocardiographer reader study, echocardiography reports co-generated with EchoChat were rated higher in diagnostic accuracy and completeness by two senior echocardiographers, and improved diagnostic performance from 72.78% to 82.75% in terms of F1 score over routine-reader only reports. These results demonstrate that integrating clinical reasoning into multimodal AI can democratize specialist expertise and transform the standard of cardiovascular care.

0.24

Text-Guided Medical Image Segmentation via Residual Aggregation and Dense Alignment Representations

cs.CV ·2026-10-10 ·Jie Gui, Hang Tu, Yunfeng Dou, Wen Sha, Xiuquan Du +1 more
publishedcode/data similarity 0.65
Abstract · Accepted at NeurIPS 2026 (poster)

Specifying segmentation targets with natural language provides flexible semantic conditioning for medical image segmentation. However, existing methods still struggle to reliably ground high-level textual semantics into accurate pixel-level spatial prompts, especially under low-contrast lesions, ambiguous boundaries, and visually similar anatomical contexts. In this paper, we propose RADAR (Residual Aggregation and Dense Alignment Representations), a parameter-efficient framework for text-guided medical image segmentation. RADAR explicitly decouples and synergizes the medical semantic anchoring capability of BiomedCLIP with the prompt-driven mask decoding ability of MedSAM2, while enabling low-cost task adaptation via LoRA. Specifically, Guided Residual Depth Aggregation adaptively aggregates cross-layer features under semantic guidance to alleviate delayed textual injection and deep semantic dilution. Structured Dense Representation Alignment leverages a frozen BiomedCLIP to construct crop-level target, boundary, and context anchors, improving the local discriminability of dense features and the reliability of automatic prompts. Multi-modal Prompt Generation further converts cross-modal semantic responses into composite text, point, and mask prompts for MedSAM2 decoding. Experiments on three public medical image segmentation datasets show that RADAR achieves competitive performance with only 0.74M trainable parameters, demonstrating its effectiveness in parameter-efficient adaptation, semantic grounding, and dense representation enhancement. The source code is available at https://github.com/JGuiidev/RADAR.

0.44

SV-Cine: Diagnosis-Conditioned Segmentation of Single Ventricle Physiology via Generative Data Augmentation

cs.CV physics.med-ph ·2026-09-11 ·Lila Cunge
similarity 0.64
Abstract · arXiv admin comment: This version has been removed by arXiv administrators as the submitter did not have the rights to agree to the license …

Single Ventricle Physiology (SVP) is a rare subtype of congenital heart disease characterized by the presence of a single functional cardiac ventricle with atypical anatomic configurations that challenge conventional image segmentation approaches. The scarcity of clinical data and the morphological diversity across SVP subtypes make the development of robust segmentation methods particularly difficult. To address these limitations, we propose a cardiac MRI segmentation framework focused on ventricular chambers and myocardium segmentation tailored for SVP. First, we introduce a data augmentation pipeline that generates synthetic 3D cardiac meshes using SDF4CHD and corresponding synthetic cardiac MRI through generative modeling. Second, we introduce SV-Cine, a diagnosis-conditioned adaptation of the foundation model CineMA that incorporates patient-level diagnostic information through Feature-wise Linear Modulation layers, enabling diagnosis-aware feature adaptation during segmentation. We evaluated the framework on an internal cohort with varying SVP subtypes. SV-Cine achieved median Dice scores of 0.89 (IQR: 0.80--0.91) for the left ventricle and 0.72 (IQR: 0.54--0.84) for the right ventricle, outperforming the strongest baseline, nnU-Net, by 0.39 Dice points on right ventricle segmentation. It also yields a median ejection fraction error of 5.55 percentage points (IQR: 3.41--7.69) for the dominant ventricle. Compared with the internal cohort, LV and myocardium segmentation performance was lower for the external cohort; whereas RV Dice scores were comparable for both cohorts. Our findings suggest that a pretrained foundation model can be adapted for highly specialized downstream tasks through usage of diagnosis priors while leveraging anatomic knowledge learned from large-scale MRI datasets during pretraining.

0.12