CS Paper Radar

A Unified DINOv2-Based Framework for LVEF Estimation, GLS Dysfunction Classification, and Early Cardiotoxicity Prediction

Xiaotong Zhang, Mingyue Cui, Qing Cao, Jingming Xia

eess.IV cs.CV ·submitted 2026-08-14 02:46 UTC · v1
published

Abstract

Left ventricular ejection fraction (LVEF) estimation (Task 1), global longitu-dinal strain (GLS)-based dysfunction classification (Task 2), and early cardi-otoxicity prediction (Task 3) provide complementary information for cardio-oncology assessment. LVEF reflects macroscopic ventricular volume chang-es as the clinical standard, whereas GLS captures subtle myocardial defor-mation, indicating subclinical cardiotoxicity before overt LVEF decline. Fur-thermore, predicting cardiotoxicity from baseline echocardiography prior to treatment enables preventive interventions at an early stage. To address these three tasks, we employ a DINOv2-based framework with task-specific adap-tation and prediction heads. Built upon a frozen foundation encoder, the framework incorporates parameter-efficient Low-Rank Adaptation (LoRA) and temporal aggregation to learn task-specialized representations, ensuring robust generalization. Crucially, during inference, it operates in a fully cycle-detection-free and phase-free manner, requiring neither cardiac cycle seg-mentation nor explicit End-Diastolic/End-Systolic (ED/ES) annotations. Ad-ditionally, we introduce an ED/ES-guided 2D/3D hybrid multi-view regres-sion model specifically to optimize Task 1. On a patient-level split containing 1,203 training videos from 237 patients and 300 validation videos from 59 independent patients, the DINOv2-based framework achieved a mean abso-lute error (MAE) of 5.03% for Task 1, an AUC-ROC of 76.48% for Task 2, and an AUC-ROC of 70.26% for Task 3. For Task 1, the specialized ED/ES-guided model further improves performance, achieving an MAE of 4.64%. This framework demonstrates the effectiveness of foundation model repre-sentations across diverse cardio-oncology tasks and the additional benefit of physiology-guided modeling for accurate LVEF estimation.

Comment
Accepted as an oral at the EchoRisk Challenge Workshop, MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

eess.IV cs.AIcs.CV ·2026-11-13 ·João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós
published similarity 0.78
Abstract · 9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challeng…

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

0.37

Learning from Scarce Labels: Multi-View Echocardiography for Ejection Fraction Prediction

eess.IV cs.CVcs.LG ·2026-09-02 ·Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
top venuedatasetcode/data similarity 0.69
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:025

We present, to the best of our knowledge, the first publicly available resource for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography. Because no PLAX-EF datasets previously existed, our work focuses on an innovative data generation strategy to overcome this scarcity. By leveraging a time-based correlation between clinical notes and echocardiographic videos, combined with fine-tuning view classifiers and proxy labeling, we created a labeled dataset of over 25,000 PLAX videos. This enables us to train the first reproducible PLAX EF model, achieving a mean absolute error (MAE) of 6.86%. Given that apical four-chamber (A4C) methods, the clinical standard, report MAE values of 6%-7%, our results demonstrate that EF estimation from PLAX views is both feasible and clinically relevant. This surpasses the performance of existing methods and provides a clinically relevant solution for situations where apical views may not be feasible. Going further, we demonstrate that combining PLAX and A4C predictions via simple unweighted late fusion improves both single-view baselines to a 6.37% MAE, underscoring the value of multi-view integration. To promote continued research, we release the dataset labels, trained models, and runnable demos on GitHub, Hugging Face, and Google Colab: https://github.com/Jeffrey4899/PLAX_EF_Labels_202509

0.46

EchoDino: A pediatric foundation model for transferable echocardiographic analysis across the lifespan

cs.CV ·2026-10-04 ·Sheng Cheng, Donnchadh M. O'Sullivan, Daniel J. Penny, Craig G. Rusin, Minh B. Nguyen +1 more
similarity 0.68
Abstract · 33 pages, 5 figures, including Supplementary Information

Echocardiography is the most widely used cardiac imaging modality, yet interpretation demands integrating visual evidence across global anatomy, localized structures and dynamic cardiac motion. Machine-learning models have automated individual tasks, but they are typically built for a single purpose and depend on expensively labeled datasets - a barrier particularly acute in pediatric care, where data are scarce and anatomy changes with age. Here we present EchoDino, a self-supervised foundation model for echocardiography, created by adapting the DINOv3 framework to 3.7 million frames from 1.7 million unlabeled pediatric echocardiography videos. With its encoder frozen, EchoDino produces representations that capture global context, local anatomy, and dense spatial detail. We introduce Motion-biased Entropy Maximization Sampling (MEMS) to select the most informative frames for video-level analysis. Across nine pediatric and adult datasets, EchoDino outperformed strong baseline models, raising view-classification accuracy from 0.609 to 0.889 and the area under the receiver operating characteristic curve for structural-heart-disease detection from 0.811 to 0.872, while also cutting age-estimation error from 3.857 to 1.389 years, achieving the best segmentation accuracy and lowering ejection-fraction errors. By generalizing from label-free pediatric data to adult echocardiography, EchoDino offers a versatile foundation for cardiac image analysis across the lifespan.

0.19

The segmentation ceiling: why explicit left-ventricular masks do not improve learned ejection-fraction regression

eess.IV cs.CV ·2026-09-17 ·Farshid Farhadi Khouzani, Paul La Plante, Bryar Mustafa Shareef, Laxmi Gewali
similarity 0.65
Abstract · 15 pages, 4 figures

Accurate estimation of left ventricular ejection fraction (EF) from echocardiography is central to cardiovascular care, and deep learning enables automated EF prediction from echocardiographic video. Because EF is clinically derived from left-ventricular (LV) volumes, a widely held intuition is that explicit LV segmentation should improve prediction. We introduce a quantitative criterion, the segmentation ceiling, that makes this testable: from EF as a normalized difference of end-diastolic and end-systolic volumes, we derive in closed form how per-frame segmentation area error propagates into EF error, and thus the accuracy a mask must reach before it can improve on direct regression. Using EchoNet-Dynamic, a UniFormer-S backbone, and the empirically measured within-patient error correlation, the criterion places the break-even near 10% per-frame area error, whereas a representative segmenter operates at roughly 14%, above the ceiling. Consistent with this, four strategies for injecting segmentation or area information (a predicted-mask channel, end-diastolic/end-systolic clip sampling, and per-bin and amplitude area-consistency objectives) fail to beat a raw-video baseline; ground-truth masks help only through label leakage. Input representation thus not being the limit, we identify generalization as the practical lever: weight averaging with strong augmentation attains a test R^2 of 0.806 (MAE 4.08) under a matched dense-clip protocol, comparable to an R(2+1)D baseline (0.811) while tightening the validation-to-test gap. Finally, a heteroscedastic beta-NLL formulation yields informative, well-calibrated per-prediction uncertainty, larger for clinically harder low-EF cases, where Monte-Carlo dropout does not. The segmentation ceiling gives a concrete design criterion for when mask-guided EF estimation is worthwhile, plus a simple, uncertainty-aware recipe for EF regression.

0.12

Domain adaptation of a video Foundation model for Heart Failure Diagnosis from Echocardiography

cs.CV ·2026-11-09 ·Mahyar Bolhassani, Tijana Geroski, Narayana S. Singam, Amir Amini
publishedcode/datahot direction similarity 0.65
Abstract · 6 pages, 6 figures, accepted and presented at Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC …

The rapid advancement of foundation models has transformed computer vision, yet their adaptation to medical imaging, particularly purpose built foundation models for spatio temporal echocardiography videos, remains limited. In this work, we explore the feasibility of fine tuning a pretrained foundation model for video (TimeSformer) for automated diagnosis of reduced ejection fraction heart failure (HFrEF) from apical four chamber videos. The model is finetuned on the publicly available RVENet A4C dataset with a phase aware clip generation strategy that captures complementary systolic and diastolic dynamics. We employ divided space time attention, layer wise learning rate decay, and multi clip inference to enhance robustness under limited data. Experimental results show that full fine tuning of the proposed model outperforms classifier only tuning and a 3D CNN baseline. These findings highlight the potential of leveraging foundation video models for echocardiography based heart failure diagnosis and motivates further domain adaptation studies in medical imaging.

0.41

CARDINAL Predicts Cardiovascular Risk From Non-contrast Cardiac CT

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-27 ·Roy Gabriel, Nattakorn Kittisut, Jamshid Hassanpour, Michael Galarnyk, Abanoub Abdelmalak +4 more
similarity 0.64
Abstract

Cardiovascular risk prediction remains limited by incomplete clinical data and imaging biomarkers that reduce computed tomography (CT) to a small number of handcrafted features. We developed CARDINAL (Cardiovascular Assessment via Representation learning from Deep Imaging with Nested Anatomical Latent embeddings), a clinically grounded framework that learns compact representations from routine non-contrast cardiac CT for major adverse cardiovascular event (MACE) prediction. In 17,659 patients, CARDINAL was evaluated for 1-, 3-, 5-, and 10-year MACE prediction against American Heart Association (AHA) pooled cohort equations (PCE), AHA predicting risk of cardiovascular disease events (PREVENT), coronary artery calcium (CAC), segmentation-derived CT biomarkers, and 70-feature structural radiomics. Gains were largest at longer horizons. At 10 years, CARDINAL (joint) achieved an area under the receiver operating characteristic curve (AUROC) of 0.866 $\pm$ 0.020 and an area under the precision-recall curve (AUPRC) of 0.890 $\pm$ 0.015, compared with an AUROC of 0.826 $\pm$ 0.023 and an AUPRC of 0.826 $\pm$ 0.022 for structural radiomics, the strongest baseline. CARDINAL also achieved the highest survival concordance index (C-index), 0.753 $\pm$ 0.015, and high-versus-low risk-tertile hazard ratio, 10.78 $\pm$ 3.16, with favorable reclassification and exploratory calibration. These findings suggest that non-contrast cardiac CT contains prognostic information beyond conventional risk equations, CAC scoring, and engineered imaging biomarkers.

0.45

CMRVision: A Foundation Model for Cardiac MR Image Analysis

cs.CV ·2026-09-01 ·Athira J. Jacob, Puneet Sharma, Daniel Rueckert
publishedbenchmark similarity 0.63
Abstract · Accepted at MedAGI 2026 (peer-reviewed workshop at MICCAI 2026)

Cardiac magnetic resonance (CMR) imaging provides complementary information on cardiac anatomy, function, and tissue characterization across multiple sequences and views. In this work, we investigate foundation model pretraining for 2D CMR and introduce CMRVision, a CMR-specific foundation model trained using DINOv3-style self-supervised learning on a multi-center, multi-sequence cohort of 36 million CMR images. We systematically evaluate architectural and training design choices for domain-specific pretraining. CMRVision is evaluated on two downstream tasks: multi-task segmentation across cine, late gadolinium enhancement (LGE), and mapping sequences, and cine view classification. Our experiments show that CMR-specific pretraining, smaller patch sizes, and patch-level objectives consistently improve downstream performance. Across a multi-task segmentation benchmark, CMRVision achieved the strongest overall performance, outperforming prior natural-image (NI), medical-image, supervised, and CMR foundation model baselines. Improvements were modest but consistent across structures and sequences, with Dice scores ranging from 0.940-0.967 for LV and 0.855-0.905 for myocardium, and reaching 0.929 for RV, 0.920 for LA, and 0.931 for RA. The largest gains were observed for myocardium segmentation in LGE and mapping images. In a zero-shot segmentation task on unseen LGE long-axis views, the model achieved an average Dice score of 0.692, demonstrating cross-view generalization. For cine view classification, CMRVision achieved the highest average accuracy (0.906), compared to prior methods reported in the literature. These results highlight the potential of CMRVision to support robust and generalizable cardiac MRI analysis across multiple sequences and views.

0.28

MR-JEPA: A General Purpose Video Foundation Model for Cardiac MRI

cs.CV cs.AI ·2026-08-31 ·Athira J. Jacob, Puneet Sharma, Dorin Comaniciu, Daniel Rueckert
published similarity 0.62
Abstract · Accepted at STACOM 2026 (MICCAI 2026 peer-reviewed workshop)

Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep learning approaches process individual 2D slices, discarding this context. We present MR-JEPA, a self-supervised video foundation model for CMR that extends LeJEPA to 3D spatiotemporal inputs through tubelet tokenization, spatiotemporal masking augmentation, and initialization from a 2D CMR foundation model. Unlike prior CMR video models limited to cine data, MR-JEPA is pretrained on multi-sequence data (cine, LGE, mapping) from 10,505 patients across two centers without annotations. We evaluate the frozen encoder on six downstream tasks using a unified multi-view gated attention architecture: LV ejection fraction, RV ejection fraction, three myocardial strains (GLS, GCS, GRS), and four-class disease detection. MR-JEPA outperforms other compared methods on all five regression tasks, including both a domain-specific CMR model pretrained on more data with text supervision and a natural-video foundation model, achieving an LV EF MAE of 4.79% (r =0.764) and a GLS MAE of 1.87 (r=0.805), with 21-27% MAE reductions over baselines on strain tasks. For disease detection, MR-JEPA achieved a macro AUG of 0.868, remaining competitive with the domain-specific baseline despite using a fully self-supervised pretraining objective. These results demonstrate the potential of a unified video encoder for robust, multi-view utilization of diverse CMR sequences in clinical cardiac quantification and diagnosis.

0.31