CS Paper Radar

Domain adaptation of a video Foundation model for Heart Failure Diagnosis from Echocardiography

Mahyar Bolhassani, Tijana Geroski, Narayana S. Singam, Amir Amini

cs.CV ·submitted 2026-11-09 22:04 UTC · v1
publishedcode/datahot direction

Abstract

The rapid advancement of foundation models has transformed computer vision, yet their adaptation to medical imaging, particularly purpose built foundation models for spatio temporal echocardiography videos, remains limited. In this work, we explore the feasibility of fine tuning a pretrained foundation model for video (TimeSformer) for automated diagnosis of reduced ejection fraction heart failure (HFrEF) from apical four chamber videos. The model is finetuned on the publicly available RVENet A4C dataset with a phase aware clip generation strategy that captures complementary systolic and diastolic dynamics. We employ divided space time attention, layer wise learning rate decay, and multi clip inference to enhance robustness under limited data. Experimental results show that full fine tuning of the proposed model outperforms classifier only tuning and a 3D CNN baseline. These findings highlight the potential of leveraging foundation video models for echocardiography based heart failure diagnosis and motivates further domain adaptation studies in medical imaging.

Comment
6 pages, 6 figures, accepted and presented at Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

eess.IV cs.AIcs.CV ·2026-11-13 ·João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós
published similarity 0.73
Abstract · 9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challeng…

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

0.37

Learning from Scarce Labels: Multi-View Echocardiography for Ejection Fraction Prediction

eess.IV cs.CVcs.LG ·2026-09-02 ·Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
top venuedatasetcode/data similarity 0.71
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:025

We present, to the best of our knowledge, the first publicly available resource for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography. Because no PLAX-EF datasets previously existed, our work focuses on an innovative data generation strategy to overcome this scarcity. By leveraging a time-based correlation between clinical notes and echocardiographic videos, combined with fine-tuning view classifiers and proxy labeling, we created a labeled dataset of over 25,000 PLAX videos. This enables us to train the first reproducible PLAX EF model, achieving a mean absolute error (MAE) of 6.86%. Given that apical four-chamber (A4C) methods, the clinical standard, report MAE values of 6%-7%, our results demonstrate that EF estimation from PLAX views is both feasible and clinically relevant. This surpasses the performance of existing methods and provides a clinically relevant solution for situations where apical views may not be feasible. Going further, we demonstrate that combining PLAX and A4C predictions via simple unweighted late fusion improves both single-view baselines to a 6.37% MAE, underscoring the value of multi-view integration. To promote continued research, we release the dataset labels, trained models, and runnable demos on GitHub, Hugging Face, and Google Colab: https://github.com/Jeffrey4899/PLAX_EF_Labels_202509

0.46

EchoDino: A pediatric foundation model for transferable echocardiographic analysis across the lifespan

cs.CV ·2026-10-04 ·Sheng Cheng, Donnchadh M. O'Sullivan, Daniel J. Penny, Craig G. Rusin, Minh B. Nguyen +1 more
similarity 0.69
Abstract · 33 pages, 5 figures, including Supplementary Information

Echocardiography is the most widely used cardiac imaging modality, yet interpretation demands integrating visual evidence across global anatomy, localized structures and dynamic cardiac motion. Machine-learning models have automated individual tasks, but they are typically built for a single purpose and depend on expensively labeled datasets - a barrier particularly acute in pediatric care, where data are scarce and anatomy changes with age. Here we present EchoDino, a self-supervised foundation model for echocardiography, created by adapting the DINOv3 framework to 3.7 million frames from 1.7 million unlabeled pediatric echocardiography videos. With its encoder frozen, EchoDino produces representations that capture global context, local anatomy, and dense spatial detail. We introduce Motion-biased Entropy Maximization Sampling (MEMS) to select the most informative frames for video-level analysis. Across nine pediatric and adult datasets, EchoDino outperformed strong baseline models, raising view-classification accuracy from 0.609 to 0.889 and the area under the receiver operating characteristic curve for structural-heart-disease detection from 0.811 to 0.872, while also cutting age-estimation error from 3.857 to 1.389 years, achieving the best segmentation accuracy and lowering ejection-fraction errors. By generalizing from label-free pediatric data to adult echocardiography, EchoDino offers a versatile foundation for cardiac image analysis across the lifespan.

0.19

MR-JEPA: A General Purpose Video Foundation Model for Cardiac MRI

cs.CV cs.AI ·2026-08-31 ·Athira J. Jacob, Puneet Sharma, Dorin Comaniciu, Daniel Rueckert
published similarity 0.68
Abstract · Accepted at STACOM 2026 (MICCAI 2026 peer-reviewed workshop)

Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep learning approaches process individual 2D slices, discarding this context. We present MR-JEPA, a self-supervised video foundation model for CMR that extends LeJEPA to 3D spatiotemporal inputs through tubelet tokenization, spatiotemporal masking augmentation, and initialization from a 2D CMR foundation model. Unlike prior CMR video models limited to cine data, MR-JEPA is pretrained on multi-sequence data (cine, LGE, mapping) from 10,505 patients across two centers without annotations. We evaluate the frozen encoder on six downstream tasks using a unified multi-view gated attention architecture: LV ejection fraction, RV ejection fraction, three myocardial strains (GLS, GCS, GRS), and four-class disease detection. MR-JEPA outperforms other compared methods on all five regression tasks, including both a domain-specific CMR model pretrained on more data with text supervision and a natural-video foundation model, achieving an LV EF MAE of 4.79% (r =0.764) and a GLS MAE of 1.87 (r=0.805), with 21-27% MAE reductions over baselines on strain tasks. For disease detection, MR-JEPA achieved a macro AUG of 0.868, remaining competitive with the domain-specific baseline despite using a fully self-supervised pretraining objective. These results demonstrate the potential of a unified video encoder for robust, multi-view utilization of diverse CMR sequences in clinical cardiac quantification and diagnosis.

0.31

A Quantitative Evaluation Framework for Temporal Explainability in Echocardiographic Video Segmentation

cs.CV cs.LG ·2026-09-07 ·Jiyoo Noh, Jonathan H. Chan
similarity 0.65
Abstract · 15 pages, 5 figures

Deep learning has achieved state-of-the-art performance in echocardiographic video segmentation, with an increasing number of models incorporating temporal information. However, quantitative evaluation of temporal explainability remains largely unexplored. We propose a quantitative framework for evaluating Grad-CAM explanations using four complementary metrics measuring temporal consistency, saliency motion, anatomical overlap, and temporal overlap. Using EchoNet-Dynamic, we compare a baseline 2D U-Net with ConvLSTM U-Net models trained across multiple temporal strides. While segmentation performance remained comparable across all models, intermediate ConvLSTM explanations exhibited substantially lower saliency consistency and greater centroid motion than final prediction explanations. Temporal Bottleneck explanations were significantly more stable than Encoder Bottleneck explanations across all strides, while final ConvLSTM Decoder3 explanations were broadly comparable to those of the 2D U-Net. Importantly, conventional frame-wise explanation metrics cannot determine whether variation in intermediate explanations reflects meaningful temporal feature evolution or explanation instability. These findings establish a preliminary quantitative framework for temporal explainability and motivate temporal-aware XAI methods that explicitly account for evolving representations in medical video models.

0.23

A Unified DINOv2-Based Framework for LVEF Estimation, GLS Dysfunction Classification, and Early Cardiotoxicity Prediction

eess.IV cs.CV ·2026-08-14 ·Xiaotong Zhang, Mingyue Cui, Qing Cao, Jingming Xia
published similarity 0.65
Abstract · Accepted as an oral at the EchoRisk Challenge Workshop, MICCAI 2026

Left ventricular ejection fraction (LVEF) estimation (Task 1), global longitu-dinal strain (GLS)-based dysfunction classification (Task 2), and early cardi-otoxicity prediction (Task 3) provide complementary information for cardio-oncology assessment. LVEF reflects macroscopic ventricular volume chang-es as the clinical standard, whereas GLS captures subtle myocardial defor-mation, indicating subclinical cardiotoxicity before overt LVEF decline. Fur-thermore, predicting cardiotoxicity from baseline echocardiography prior to treatment enables preventive interventions at an early stage. To address these three tasks, we employ a DINOv2-based framework with task-specific adap-tation and prediction heads. Built upon a frozen foundation encoder, the framework incorporates parameter-efficient Low-Rank Adaptation (LoRA) and temporal aggregation to learn task-specialized representations, ensuring robust generalization. Crucially, during inference, it operates in a fully cycle-detection-free and phase-free manner, requiring neither cardiac cycle seg-mentation nor explicit End-Diastolic/End-Systolic (ED/ES) annotations. Ad-ditionally, we introduce an ED/ES-guided 2D/3D hybrid multi-view regres-sion model specifically to optimize Task 1. On a patient-level split containing 1,203 training videos from 237 patients and 300 validation videos from 59 independent patients, the DINOv2-based framework achieved a mean abso-lute error (MAE) of 5.03% for Task 1, an AUC-ROC of 76.48% for Task 2, and an AUC-ROC of 70.26% for Task 3. For Task 1, the specialized ED/ES-guided model further improves performance, achieving an MAE of 4.64%. This framework demonstrates the effectiveness of foundation model repre-sentations across diverse cardio-oncology tasks and the additional benefit of physiology-guided modeling for accurate LVEF estimation.

0.18

SV-Cine: Diagnosis-Conditioned Segmentation of Single Ventricle Physiology via Generative Data Augmentation

cs.CV physics.med-ph ·2026-09-11 ·Lila Cunge
similarity 0.64
Abstract · arXiv admin comment: This version has been removed by arXiv administrators as the submitter did not have the rights to agree to the license …

Single Ventricle Physiology (SVP) is a rare subtype of congenital heart disease characterized by the presence of a single functional cardiac ventricle with atypical anatomic configurations that challenge conventional image segmentation approaches. The scarcity of clinical data and the morphological diversity across SVP subtypes make the development of robust segmentation methods particularly difficult. To address these limitations, we propose a cardiac MRI segmentation framework focused on ventricular chambers and myocardium segmentation tailored for SVP. First, we introduce a data augmentation pipeline that generates synthetic 3D cardiac meshes using SDF4CHD and corresponding synthetic cardiac MRI through generative modeling. Second, we introduce SV-Cine, a diagnosis-conditioned adaptation of the foundation model CineMA that incorporates patient-level diagnostic information through Feature-wise Linear Modulation layers, enabling diagnosis-aware feature adaptation during segmentation. We evaluated the framework on an internal cohort with varying SVP subtypes. SV-Cine achieved median Dice scores of 0.89 (IQR: 0.80--0.91) for the left ventricle and 0.72 (IQR: 0.54--0.84) for the right ventricle, outperforming the strongest baseline, nnU-Net, by 0.39 Dice points on right ventricle segmentation. It also yields a median ejection fraction error of 5.55 percentage points (IQR: 3.41--7.69) for the dominant ventricle. Compared with the internal cohort, LV and myocardium segmentation performance was lower for the external cohort; whereas RV Dice scores were comparable for both cohorts. Our findings suggest that a pretrained foundation model can be adapted for highly specialized downstream tasks through usage of diagnosis priors while leveraging anatomic knowledge learned from large-scale MRI datasets during pretraining.

0.12

Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI Reconstruction

cs.CV ·2026-10-06 ·Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
publishedcode/data similarity 0.64
Abstract · Accepted at ECCVW 2026

Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while preserving diagnostic fidelity. Recent reconstruction methods are typically trained from scratch and often require large amounts of task-specific data, limiting their robustness under data scarcity and distribution shifts. In this work, we investigate whether pretrained vision foundation models can serve as effective priors for accelerated cardiac MRI reconstruction. We propose a reconstruction framework that integrates frozen and parameter-efficiently adapted visual encoders, including CLIP, BiomedCLIP, and DINOv2, within a transformer-based reconstruction architecture. Extensive experiments on the CMRxRecon2023 and CMRxRecon2024 benchmarks demonstrate that pretrained representations consistently outperform a transformer trained from scratch across multiple acceleration factors. We further evaluate performance under limited supervision and cross-dataset transfer, showing that foundation models provide superior data efficiency and generalization. While frozen representations are particularly effective in extreme low-data regimes, Low-Rank Adaptation (LoRA) yields additional gains when moderate amounts of training data are available. Among the evaluated backbones, DINOv2 achieves the strongest overall performance. These findings highlight the potential of vision foundation models as robust and transferable priors for cardiac MRI reconstruction.

0.31