CS Paper Radar

Robust Transfer Learning for Paper ECG Recognition

Yinghao Xie, Zhenbang Dai, Haojun Wang, Jinyu Cai, Fabio Bonassi, Hongwu Chen, Johan Sundström, Jiawei Li, Antônio H. Ribeiro

cs.LG cs.AI ·submitted 2026-09-30 12:11 UTC · v1

Abstract

Paper ECG recognition is challenging because real-world ECG images vary in layout, physical artifacts, and label availability. We introduce RobECG-CL, a rank-aware contrastive learning framework for robust paper ECG representation learning. Starting from standard 12-lead ECG recordings, we construct progressively degraded paper ECG views with heterogeneous layouts and train the model to balance same-recording invariance with degradation-aware ordering. Across synthetic stress tests on CODE-II and EchoNext, RobECG-CL improves robustness under severe degradation and few-shot transfer, outperforming contrastive learning baselines and surpassing the waveform-based foundation model, ECG-FM, in the 1% labeled setting. On 312 samples of hospital data with 37 labels, RobECG-CL achieves the best macro AUROC.

Closest papers

Nearest neighbours by meaning across the whole index.

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.74
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.32

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.70
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for Electrocardiogram

cs.AI ·2026-10-20 ·Huynh Dang Nguyen, Trong-Thang Pham, Anh-Thuan Do, Phuong-Nhi Dinh, Brijesh Patel +2 more
published similarity 0.68
Abstract · Accepted in WACV 2027

Electrocardiography (ECG) is a cornerstone of cardiac diagnosis, yet most machine learning methods for ECG analysis lack interpretability, limiting their clinical adoption. We present IECG, a weakly-supervised ECG foundation model that jointly performs diagnostic classification and abnormality localization without requiring manual abnormal region annotations, overcoming a long-standing bottleneck in interpretable ECG learning. Central to IECG is a weakly-supervised attention strategy that explicitly incorporates clinical priors by deriving abnormality heatmap pseudo-labels from established ECG clinical knowledge. These pseudo-labels guide the model's CLS-token attention through a KL-divergence loss, encouraging it to focus on diagnostically relevant waveform regions. During pretraining, IECG is jointly optimized with clinically guided attention supervision, ECG-text contrastive alignment, and report captioning objectives, enabling it to learn rich multimodal representations while producing localized waveform evidence. By explicitly aggregating features from clinically guided attention regions, IECG grounds its diagnostic predictions in interpretable waveform evidence without sacrificing classification performance. Extensive experiments demonstrate that IECG achieves state-of-the-art abnormal region localization while maintaining strong classification performance, advancing trustworthy foundation models for ECG analysis.

0.31

DiSR-ECG: Residual Shifting Conditional Diffusion for Robust ECG Super-Resolution

eess.SP ·2026-09-15 ·Fan-Yi Hsu, I Chiu, Kuan-Chen Wang, Sheng-Yu Peng, Yu Tsao
published similarity 0.65
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026)

Electrocardiogram (ECG) signals are essential for arrhythmia diagnosis. With the growing adoption of long-term monitoring via wearable and portable devices, energy-efficient acquisition has become critical, motivating the development of ECG super-resolution (SR) techniques to reconstruct high-resolution signals from low-sampling-rate inputs. While recent SR methods based on discriminative neural networks have shown strong performance, their robustness under distribution shift remains uncertain, which poses a key challenge for real-world deployment. In this study, we propose DiSR-ECG, a residual shifting conditional diffusion framework for robust ECG SR. The model integrates residual shifting with Mamba-based temporal modeling and conditional guidance to enable accurate multi-lead reconstruction. Experiments on two large-scale ECG databases, PTB-XL for in-domain evaluation and Chapman Shaoxing for cross-dataset evaluation, demonstrate that DiSR ECG achieves state-of-the-art performance in both settings, with particularly strong generalization under distribution shift. These results highlight the potential of DiSR-ECG to provide reliable and clinically applicable ECG reconstruction for real-world monitoring.

0.25

Leveraging Cardiac Imaging to Improve ECG-Based Detection of Chagas Disease in Resource-Constrained Settings

cs.LG cs.AIeess.IV ·2026-09-08 ·Laura Alvarez-Florez, Daniel Uyterlinde, Samuel Ruipérez-Campillo, Lukas P. A. Arts, Folkert W. Asselbergs +1 more
similarity 0.65
Abstract

Chagas disease is a major cause of cardiomyopathy in Latin America. Cardiac magnetic resonance (CMR) imaging can characterize its structural abnormalities, but scanners and expert readers remain scarce in endemic regions. Electrocardiography (ECG) is inexpensive and widely available, yet structural disease must be inferred indirectly from electrical signals. We propose to transfer CMR-derived structural knowledge to ECG through contrastive pre-training. Using 63,193 paired ECG-CMR examinations from the UK Biobank, we align an ECG encoder with a clinically grounded CMR embedding space using an asymmetric InfoNCE objective. Despite seeing no Chagas cases during pre-training, the resulting representation improves ECG-based Chagas detection. Across CODE-15% and SaMi-Trop, a frozen linear probe achieves an AUROC of 0.851 and sensitivity at the top 5% of predicted risk (Top5%-TPR) of 0.427 in five-fold cross-validation, compared with 0.827 and 0.377 for an unaligned ECG-FM baseline. On the PhysioNet/CinC 2025 Challenge test set, our model obtains the highest AUROC on SaMi-Trop-3 and the best ELSA-Brasil challenge score among the three top-performing methods, indicating that imaging-supervised ECG representations can generalize to populations and settings beyond the pre-training distribution.

0.12

Graph-Based Pseudo-multimodal Contrastive Learning for 12-Lead ECG Representations

cs.LG ·2026-08-27 ·Mengyu Wang, Kozo Okada, Takafumi Goto, Natsuko Jinba, Hiroki Yamaya +2 more
published similarity 0.64
Abstract · 7 pages, 7 figures. Presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026…

12-lead electrocardiogram (ECG) is a standard, non-invasive examination widely used for diagnosing coronary artery disease, where clinical interpretation relies on comparing waveform patterns across multiple leads. However, most existing ECG analysis methods focus on single-lead signals or treat each lead independently, and typically process ECG signals as one-dimensional time-series data using CNNs or RNNs. While effective in modeling local waveform changes, such approaches have difficulty capturing inter-lead dependency and global waveform patterns essential for clinical diagnosis. To address this limitation, we propose a graph-based pseudo-multimodal contrastive learning framework called Graph-CMMC. ECG waveforms are transformed into Gramian Angular Difference Field (GADF) images to construct complementary representations of the same cardiac activity, enabling a pseudo-multimodal learning setting. Using all 12 leads, Graph-CMMC aligns waveform and GADF representations in a self-supervised manner, while a graph-based relational module is employed to model inter-lead dependency and enforce structural consistency across leads during contrastive learning. Experimental results on a multi-label coronary artery occlusion classification task demonstrate that the proposed framework achieves competitive performance compared to supervised learning methods. These results further suggest the effectiveness of using GADF as a complementary representation and incorporating explicit graph-based modeling of inter-lead dependency for learning robust 12-lead ECG representations.

0.32

Diagnosing as Cardiologists Do: ECG Agents with Doctor-Grounded Priors for Clinical Reasoning Across Diseases and Populations

eess.SP cs.CVcs.LG ·2026-08-10 ·Hongxiang Gao, He-yang Xu, Yuwen Li, Minghui Zhao, Zhipeng Cai +4 more
benchmark similarity 0.63
Abstract

Cardiologists interpret electrocardiograms by localizing waveform components, measuring rhythm and interval patterns, and translating these structured observations into diagnostic evidence. Whether this expert reading process can serve as an effective prior for ECG agents remains unclear. To address this question, we introduce LuminaECG, a clinically structured ECG reasoning framework that reformulates ECG interpretation as measurement-grounded visual reading. ECG signals are rendered on standard electrocardiographic grid paper to preserve the spatial and scale cues used in clinical reading. P-wave, QRS-complex, and T-wave boundaries are explicitly delineated, and color-coded segmentation decomposes the waveform into discrete visual measurement primitives. A general 2B vision-language backbone is then trained with low-rank supervised fine-tuning to associate these primitives with diagnostic reasoning, without architectural modification. Across open, proprietary, and ECG-specialist zero-shot baselines, LuminaECG improves both waveform measurement and diagnostic recovery. It reaches a clinically meaningful reader tier on the CODE-test benchmark, transfers across geographically diverse ECG datasets without retraining, and generates reports whose structure contains an emergent prognostic signal. These findings suggest that effective ECG agents require not only larger models, but supervision that preserves the alignment between measurable waveform evidence and clinical knowledge.

0.04

From ECG Signals to Representative-Morphology Heatmaps for Biometric Recognition

cs.CV eess.SP ·2026-09-23 ·Athanasios Angelakis, Marta Gomez-Barrero
similarity 0.63
Abstract · 31 pages, 7 figures, 14 tables

Electrocardiography (ECG) contains subject-specific morphology that supports biometric recognition, yet image-based performance depends on how the waveform is rendered. We introduce representative-morphology heatmaps, a deterministic ECG-to-image representation adapted from ECGXtractor. Within each block of ten aligned beats, the five beats closest to the block mean are averaged into a 400 by L matrix and rendered either as a conventional trace or as a dense cardiac-time-by-lead heatmap. Since both representations contain identical physiological samples, their comparison isolates the effect of rendering. We evaluate verification and closed-set identification on PTB, ECG-ID, and MIMIC-IV-ECG-DEMO. Five compact models, including ZACH-ViT, are trained from scratch, while six ImageNet-pretrained CNN and transformer backbones assess model scale and visual transfer. Heatmaps improve both FNMR operating points and both identification ranks in all 15 compact model-dataset comparisons, while EER improves in 14. Across the matched experiments, EER decreases by 9.59 percentage points and Rank-1 increases by 24.69 points on average. ConvNeXt-Tiny reaches 2.43% EER on PTB and 5.79% on ECG-ID, whereas DeiT-Base reaches 14.92% on MIMIC-DEMO. ImageNet initialization clearly benefits the two multilead datasets but has a mixed effect on ECG-ID, and performance does not increase monotonically with model size. The best heatmap systems approach the strongest signal-domain EER on PTB and ECG-ID, while DeiT-Base provides the strongest evaluated performance on MIMIC-DEMO. Lead-channel ablation further shows that useful channel combinations depend on the cohort and biometric task. Overall, representative-morphology heatmaps provide an effective image representation for ECG verification and identification.

0.21