CS Paper Radar

From ECG Signals to Representative-Morphology Heatmaps for Biometric Recognition

Athanasios Angelakis, Marta Gomez-Barrero

cs.CV eess.SP ·submitted 2026-09-23 14:25 UTC · v1

Abstract

Electrocardiography (ECG) contains subject-specific morphology that supports biometric recognition, yet image-based performance depends on how the waveform is rendered. We introduce representative-morphology heatmaps, a deterministic ECG-to-image representation adapted from ECGXtractor. Within each block of ten aligned beats, the five beats closest to the block mean are averaged into a 400 by L matrix and rendered either as a conventional trace or as a dense cardiac-time-by-lead heatmap. Since both representations contain identical physiological samples, their comparison isolates the effect of rendering. We evaluate verification and closed-set identification on PTB, ECG-ID, and MIMIC-IV-ECG-DEMO. Five compact models, including ZACH-ViT, are trained from scratch, while six ImageNet-pretrained CNN and transformer backbones assess model scale and visual transfer. Heatmaps improve both FNMR operating points and both identification ranks in all 15 compact model-dataset comparisons, while EER improves in 14. Across the matched experiments, EER decreases by 9.59 percentage points and Rank-1 increases by 24.69 points on average. ConvNeXt-Tiny reaches 2.43% EER on PTB and 5.79% on ECG-ID, whereas DeiT-Base reaches 14.92% on MIMIC-DEMO. ImageNet initialization clearly benefits the two multilead datasets but has a mixed effect on ECG-ID, and performance does not increase monotonically with model size. The best heatmap systems approach the strongest signal-domain EER on PTB and ECG-ID, while DeiT-Base provides the strongest evaluated performance on MIMIC-DEMO. Lead-channel ablation further shows that useful channel combinations depend on the cohort and biometric task. Overall, representative-morphology heatmaps provide an effective image representation for ECG verification and identification.

Comment
31 pages, 7 figures, 14 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Vision-language classification of Torsades de Pointes risk from pseudo-coloured ECG images: do T-wave morphology and colour context help or hinder?

cs.CV ·2026-11-01 ·Dario Labrador Alonso, Alaa Alahmadi
similarity 0.66
Abstract

Contextual prompting is widely presented as a cheap route to better performance from vision models, but the evidence comes largely from benchmarks in which an attribute named in a prompt is also present in the image, confounding the two channels. We investigate the significance of context for a semantically complex biomedical signal classification task using a domain-adapted vision-language model, BiomedCLIP. Building on our previous work that renders electrocardiogram (ECG) signals as colour-enhanced images to flag Torsades de Pointes risk using the QT-nomogram and pseudo-colouring technique, we cross four context strategies with four T-wave morphology label sets, evaluated zero-shot and with a class-balanced linear probe, under five-fold stratified cross-validation on 9,789 images. Zero-shot inference is unusable. Once trained, the colour-enhanced images outperform the colourless ones on every metric: balanced accuracy 0.903 versus 0.825, sensitivity 0.914 versus 0.827, specificity 0.892 versus 0.823, ROC-AUC 0.955 versus 0.888 and Matthews correlation coefficient (MCC) 0.437 versus 0.311. Crossing colour-in-image with colour-in-prompt separates the confounded channels: the image contributes +0.126 MCC (+0.078 balanced accuracy, +0.067 ROC-AUC) whether or not the prompt names colour, whereas naming it changes nothing under any metric. Context is two-sided: the best prompt set gains 0.008 MCC where colour is present and 0.016 where it is not, while the worst loses 0.017 and 0.013. For a signal rendered as an image, the leverage lies in how the signal is drawn rather than in how it is described - and where the endpoint is an interval measurement, prompts naming T-wave morphology describe the wrong quantity.

0.22

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.65
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.65
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.20

ECG Mirage: Revealing and Mitigating the Underutilisation of ECGs in Vision-Language Models for Clinical Prediction

cs.AI ·2026-09-18 ·Jinning Liang, Mingcheng Zhu, Tingting Zhu
similarity 0.64
Abstract

Emergency department (ED) decision-making relies on heterogeneous clinical information, including patient history, vital signs, laboratory results, and electrocardiograms (ECGs). Vision--language models (VLMs) can jointly process these modalities, but strong predictive performance does not necessarily imply meaningful use of the correct patient's ECG. We term this failure mode ECG Mirage: apparent multimodal capability without useful dependence on patient-specific ECG information. We distinguish two forms: ECG neglect, where ECGs provide little predictive benefit, and ECG confusion, where matched ECGs outperform no-image inputs but not mismatched ECGs. To evaluate these behaviours, we compare predictions obtained with matched ECGs, outcome-discordant mismatched ECGs, and no-image inputs while holding the clinical text and prediction targets fixed. Across four VLMs on MDS-ED, matched ECGs provide no consistent advantage for either ICU admission or clinical deterioration prediction. We then train four restricted visual prompts using supervised learning followed by conditional direct preference optimisation, while keeping the VLM backbone frozen. The resulting models achieve balanced accuracies of 70.6% for ICU admission and 67.5% for deterioration and increase the matched-versus-mismatched performance gap to approximately 16.5 and 5.5 percentage points, respectively. Overall, our study identifies ECG Mirage in multimodal clinical prediction and introduces visual prompt tuning as an efficient mitigation strategy.

0.36

Holtercare-Bench: A Multimodal Benchmark for Evaluating Long-Term Dynamic ECG Analysis

cs.LG ·2026-08-19 ·Yihan Xie, Hanwen Cui, Runze Ye, Juekai Lin, Haoyang Wang +6 more
top venuebenchmarkcode/data similarity 0.64
Abstract

While multimodal large language models (MLLMs) excel in medical applications, most of them favor static images or short-term signals. In the critical field of dynamic electrocardiograms (ECG), models struggle with complex temporal reasoning and diagnostic report generation due to a lack of high-quality datasets and benchmarks. To address this, we introduce (i) Holtercare-23K, a large-scale multimodal dynamic ECG dataset comprising 22,980 QA pairs derived from 788 clinical Holter records and featuring a novel signal-video-text tri-modal alignment. Based on this dataset, we present (ii) Holtercare-Bench, a multimodal benchmark that evaluates models on temporal localization, clinical diagnosis, and global summarization. Zero-shot evaluations of leading MLLMs reveal a significant performance gap in processing ultra-long pathological sequences. However, fine-tuning representative models yields substantial improvements. This work illuminates the limitations of current MLLMs in electrophysiology and provides a foundational benchmark for long-term medical MLLMs. Our project is available at https://github.com/ZJU4HealthCare/Holtercare-Bench.

0.47

A Hybrid CNN--State-Space--Attention Backbone with Joint-Embedding Predictive Pretraining for 12-Lead ECG Classification

cs.CV ·2026-09-24 ·Yakoub Bazi, Sarah Aljuhani, Mohamad M. Al Rahhal, Mansour Zuair, Naif Alajlan
code/data similarity 0.63
Abstract

Automatic 12-lead electrocardiogram (ECG) classification requires representations that jointly capture local waveform morphology, long-range temporal dynamics, and cross-lead dependencies, yet integrating these properties within a single efficient architecture remains challenging. This paper introduces a hybrid CNN-SSM-Attention backbone for 12-lead ECG classification. A convolutional stem performs early waveform tokenization and temporal reduction, mixed state-space and depthwise-convolutional blocks model temporal dynamics and local morphology, and a late self-attention stage enables global token interaction at reduced resolution. To improve transfer from unlabeled data, we further develop an ECG-oriented Joint-Embedding Predictive Pretraining (JEPA) framework. Unlike ViT-based JEPA methods that mask patch tokens before the encoder, the proposed method samples span masks at the latent temporal resolution and projects them back to the waveform domain, then predicts clean latent targets from a momentum encoder without waveform reconstruction. Experiments on CPSC2018, Chapman-Shaoxing, and PTB-XL, with pretraining on approximately 350K unlabeled CODE-15 recordings, show that the proposed backbone provides strong supervised baselines under a compact parameter budget. JEPA pretraining further improves transfer, particularly in reduced-label settings and under both full fine-tuning and LoRA-based adaptation. Code: https://github.com/yakoubbazi/Hybrid_ECG_Jepa

0.26

Robust Transfer Learning for Paper ECG Recognition

cs.LG cs.AI ·2026-09-30 ·Yinghao Xie, Zhenbang Dai, Haojun Wang, Jinyu Cai, Fabio Bonassi +4 more
similarity 0.63
Abstract

Paper ECG recognition is challenging because real-world ECG images vary in layout, physical artifacts, and label availability. We introduce RobECG-CL, a rank-aware contrastive learning framework for robust paper ECG representation learning. Starting from standard 12-lead ECG recordings, we construct progressively degraded paper ECG views with heterogeneous layouts and train the model to balance same-recording invariance with degradation-aware ordering. Across synthetic stress tests on CODE-II and EchoNext, RobECG-CL improves robustness under severe degradation and few-shot transfer, outperforming contrastive learning baselines and surpassing the waveform-based foundation model, ECG-FM, in the 1% labeled setting. On 312 samples of hospital data with 37 labels, RobECG-CL achieves the best macro AUROC.

0.16

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.63
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17