Multimodal large language models (MLLMs) can now interpret a standard ten-second, twelve-lead electrocardiogram (ECG) with clinically grounded, reward-verified reasoning. Real cardiac monitoring is different. Ambulatory (Holter) and telemetry recordings span hours to days and are read as they stream in, and their clinically decisive findings are paroxysmal, brief episodes buried in an otherwise unremarkable trace. Such a recording cannot be held in one context at diagnostic resolution, and its future has not yet happened, so a reader must work online, deciding what to measure now, committing evidence to memory as it passes, and reporting events as they occur. We recast long-duration ECG interpretation as a long-horizon, online (streaming, causal) sequential decision process and introduce ECG-Scroll. As a benchmark, long ambulatory recordings are streamed to an agent chunk by chunk, and it must localize, quantify, and promptly flag paroxysmal events without access to future signal; because the underlying signal is retained, every answer is checkable against objective ground truth, giving rule-based rather than judge-based rewards, and the streaming formulation adds a metric batch evaluation cannot express, the detection latency between an event's onset and the moment the agent records it. As an agent environment, it is a fixed, gym-style interaction layer that exercises three competencies single-glance ECG models never touch: Memory, Tool use through signal-grounded measurement rather than reading pixels, and Planning of what to measure now and when to commit. We release 390 whole-recording instances spanning 2,536 hours of two-lead ambulatory ECG and evaluate a signal-threshold rule agent alongside off-the-shelf LLM agents online, characterizing how they use memory, tools, and planning and where the benchmark's head-room lies.

Closest papers

Nearest neighbours by meaning across the whole index.

Holtercare-Bench: A Multimodal Benchmark for Evaluating Long-Term Dynamic ECG Analysis

cs.LG ·2026-08-19 ·Yihan Xie, Hanwen Cui, Runze Ye, Juekai Lin, Haoyang Wang +6 more
top venuebenchmarkcode/data similarity 0.70
Abstract

While multimodal large language models (MLLMs) excel in medical applications, most of them favor static images or short-term signals. In the critical field of dynamic electrocardiograms (ECG), models struggle with complex temporal reasoning and diagnostic report generation due to a lack of high-quality datasets and benchmarks. To address this, we introduce (i) Holtercare-23K, a large-scale multimodal dynamic ECG dataset comprising 22,980 QA pairs derived from 788 clinical Holter records and featuring a novel signal-video-text tri-modal alignment. Based on this dataset, we present (ii) Holtercare-Bench, a multimodal benchmark that evaluates models on temporal localization, clinical diagnosis, and global summarization. Zero-shot evaluations of leading MLLMs reveal a significant performance gap in processing ultra-long pathological sequences. However, fine-tuning representative models yields substantial improvements. This work illuminates the limitations of current MLLMs in electrophysiology and provides a foundational benchmark for long-term medical MLLMs. Our project is available at https://github.com/ZJU4HealthCare/Holtercare-Bench.

0.47

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

cs.LG eess.SP ·2026-08-13 ·Ahmed Sameh, Ramzi Al-Sharawi, Yogatheesan Varatharajah
publishedcode/data similarity 0.69
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026). 6 pages, 2 figures…

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.

0.41

Diagnosing as Cardiologists Do: ECG Agents with Doctor-Grounded Priors for Clinical Reasoning Across Diseases and Populations

eess.SP cs.CVcs.LG ·2026-08-10 ·Hongxiang Gao, He-yang Xu, Yuwen Li, Minghui Zhao, Zhipeng Cai +4 more
benchmark similarity 0.68
Abstract

Cardiologists interpret electrocardiograms by localizing waveform components, measuring rhythm and interval patterns, and translating these structured observations into diagnostic evidence. Whether this expert reading process can serve as an effective prior for ECG agents remains unclear. To address this question, we introduce LuminaECG, a clinically structured ECG reasoning framework that reformulates ECG interpretation as measurement-grounded visual reading. ECG signals are rendered on standard electrocardiographic grid paper to preserve the spatial and scale cues used in clinical reading. P-wave, QRS-complex, and T-wave boundaries are explicitly delineated, and color-coded segmentation decomposes the waveform into discrete visual measurement primitives. A general 2B vision-language backbone is then trained with low-rank supervised fine-tuning to associate these primitives with diagnostic reasoning, without architectural modification. Across open, proprietary, and ECG-specialist zero-shot baselines, LuminaECG improves both waveform measurement and diagnostic recovery. It reaches a clinically meaningful reader tier on the CODE-test benchmark, transfers across geographically diverse ECG datasets without retraining, and generates reports whose structure contains an emergent prognostic signal. These findings suggest that effective ECG agents require not only larger models, but supervision that preserves the alignment between measurable waveform evidence and clinical knowledge.

0.04

TRACE: Expert-Aligned ECG Representation Learning with Rigorous Benchmarking and Real-World Validation in Acute Cardiac Care

cs.LG cs.AI ·2026-09-28 ·Lovely Yeswanth Panchumarthi, Andrew Lu, Saurabh Kataria, Delgersuren Bold, Minxiao Wang +9 more
benchmark similarity 0.67
Abstract · 42 pages, 4 figures and 1 table

TRACE (Text-Reinforced Analysis of Cardio ECGs) is a multimodal electrocardiogram (ECG) representation model that learns clinically grounded signal embeddings for downstream cardiac classification. It is designed to address the limitations of existing CLIP-style training, which often struggles with noisy clinical text and fails to leverage the complementary strengths of unimodal (from ECG) and cross-modal (between ECG and matched cardiologist reports) learning. To bridge this gap, we propose a hybrid architecture that jointly learns unimodal and cross-modal representations via uncertainty-weighted multi-task learning while utilizing an LLM-based pipeline to extract high-fidelity findings from cardiologist reports. We evaluate TRACE across a spectrum of clinical urgency, establishing robust performance on public benchmarks for arrhythmia classification and structural abnormalities relative to existing unimodal and multimodal ECG models. To demonstrate real-world utility, we further validate the model on acute coronary occlusion (ACO), where the prevailing ST-elevation criteria miss 25-34% of true occlusions. Utilizing a large private ACO dataset with expert-annotated ground truth, TRACE significantly outperforms real-world clinical practice, yielding a 19.0% increase in sensitivity or a 62.6% reduction in false positive rates at the clinical baseline. This extensive evaluation confirms that TRACE delivers both strong performance on benchmark tasks and tangible clinical impact in the most acute, high-risk cardiac scenarios.

0.11

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.67
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

Large language models in medical time series analysis

eess.SP cs.AIcs.LG ·2026-09-07 ·Yu Han, Cigdem Beyan, Xiang Zhang, Xiaofeng Liu, Nan Liu +4 more
code/data similarity 0.67
Abstract

Medical time series (MedTS), including electrocardiograms (ECG), electroencephalograms (EEG), photoplethysmography (PPG), and vital-sign recordings, are central to clinical diagnosis and health monitoring. As large language models (LLMs) have advanced, a growing body of work has examined how their reasoning, generation, and knowledge-integration capabilities can support MedTS analysis. Yet existing studies remain scattered, and the field still lacks a clear view of how these models should be designed, integrated into clinical workflows, and evaluated. This review synthesizes recent work on large language models for medical time series analysis (MedTSLLMs), covering both methodological progress and issues related to real-world deployment. We review model architectures, data resources, and processing pipelines, and prompt design strategies adapted for diverse clinical scenarios. We further organize existing MedTS applications, ranging from diagnostic interpretation and report generation to longitudinal health monitoring and physiological signal synthesis, highlighting task-specific design choices, common evaluation protocols, and empirical findings reported across studies. By bringing together current practices and open challenges, this review aims to provide a clearer foundation for developing, evaluating, and deploying MedTSLLMs responsibly in healthcare. We also maintain a regularly updated list of MedTSLLM studies and resources at: https://github.com/hy727/MedTSLLM-Review.

0.34

ECGJev: Question-Conditioned Option Scoring for 12-Lead ECG Interpretation

cs.LG eess.SP ·2026-11-01 ·Zhuoyuan Li, Xidong Wu, Hanyu Cui, Jiansong Gao, Rongrong Fu +2 more
code/datahot direction similarity 0.66
Abstract · 5 pages (4 pages plus ethics statement and references), 2 figures. Submitted to IEEE ISBI 2027. Zhuoyuan Li and Xidong Wu contributed equall…

Clinical interpretation of a 12-lead electrocardiogram (ECG) often requires answering targeted diagnostic questions with clear, quantifiable decisions. We introduce ECGJev, the first ECG framework built on a decision decoder, a pretrained language model trained to return a probability for every listed option. A question-conditioned bridge compresses frozen waveform and spectrogram features into 16 ECG tokens, and a two-stage procedure adapts the bridge and low-rank adapters on the decoder's native option readout using diagnostic labels alone, scoring all options for a question in one forward pass. Evaluated across four ECG benchmarks, ECGJev achieves the highest macro-F1 on CPSC2018 (80.46%), PTB-XL (71.68%) and Chapman (96.86%), and generalizes competitively to the small-sample PTB cohort. Concept probes and perturbation analyses further show that its predictions rely directly on the ECG input, remain stable under option-order and wording variations, and transfer zero-shot to unseen waveform concepts. Our code is available at https://github.com/zhuoyuanli-lab/ECGJev.

0.34

LEAP-LLM: Preserving lead-time structure for question-conditioned ECG interpretation

cs.LG cs.AI ·2026-11-13 ·Aakash Agarwal, Yidan Shen, Xin Fu, Renjie Hu
similarity 0.66
Abstract · 23 Pages including Appendix

The electrocardiogram (ECG) records cardiac electrical activity across multiple leads and is used for detecting cardiac abnormalities. Recent ECG-language models enable large language models (LLMs) to interpret cardiac signals and answer clinically relevant questions. However, existing ECG-language models typically encode the ECG independently of the clinical question, forcing the ECG representation to retain broad and potentially irrelevant signal information. Moreover, these models often aggregate information across leads which can obscure lead-specific details needed for a particular question. To tackle these limitations, we introduce LEAP-LLM, an ECG-LLM architecture for Lead-aware ECG Alignment with Prompt conditioning. LEAP-LLM uses the clinical question to guide ECG feature extraction while preserving explicit lead and temporal structure. Task-trained instruction representations distill information from the question and guide two complementary branches. The Lead branch captures question-relevant temporal patterns within each ECG lead, while the Temporal branch summarizes relevant information across leads at each temporal position. Together, they provide the LLM with compact, question-relevant ECG information while preserving lead and temporal structure. LEAP-LLM reduces modality-token count by 89.0% and prefill FLOPs by 7.2x on average relative to other ECG-LLMs baselines. Across four ECG benchmarks, LEAP-LLM achieves better performance, including a 3.4-percentage-point improvement in G12EC over the strongest prior ECG-specific method. We further show that the model adaptively emphasizes the clinically relevant anatomical lead groups for different cardiac abnormalities, with lead importance patterns consistent with established diagnostic knowledge, providing interpretable evidence that the predictions are supported by clinically meaningful ECG structure.