CS Paper Radar

CardioVascBench:Prioritized Diagnosis Generation from Real-World Chinese Cardiovascular Records

Minghao Kong, Muyao Chen, Jianhao Wu, Yuqiang Zhang, Xiangbin Meng, Zirong Liu, Ting Cao, Kaida Ning, Zhen Song, Rongjie Wang

cs.CL ·submitted 2026-11-03 11:09 UTC · v1
benchmark

Abstract

Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance. We introduce CardioVascBench, a retrospective benchmark for prioritized diagnosis generation from real-world Chinese cardiovascular inpatient records. It contains 3,262 de-identified cases, with 2,174 for training and 1,088 for evaluation, linking clinical narratives and textual ECG reports to expert-verified, ordered discharge diagnoses standardized to ICD-10. An English translation of the evaluation set supports aligned cross-lingual comparison. Our evaluation protocol combines terminology normalization and rank-aware scoring to separately assess primary-diagnosis identification, reference-diagnosis coverage, and list precision. Evaluation across 36 systems shows that higher primary-diagnosis accuracy does not necessarily imply higher list precision against discharge references. We also provide CardioKG-Agent, a knowledge-enhanced baseline combining entity normalization, constrained graph retrieval, and guideline evidence. In a staged comparison of three baseline models, supervised fine-tuning plus the agent achieves a 73.5% higher mean composite score than fine-tuning alone, representing a system-level gain. These results measure retrospective agreement with recorded diagnoses; agreement between metric rankings and physician judgments remains to be validated. CardioVascBench supports research on diagnosis prioritization and knowledge-enhanced generation.

Comment
26 pages,17 figures,5 tables,including appendices

Closest papers

Nearest neighbours by meaning across the whole index.

ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography

cs.CL cs.IR ·2026-08-31 ·Mohammadsina Hassannia, Matthew A. Reyna, Reza Sameni
benchmarkcode/data similarity 0.67
Abstract

Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.

0.35

CardioLM: A multilingual suite of small language models for the cardiology domain

cs.CL cs.AI ·2026-11-05 ·Manuela-Daniela Danu, Miguel Rodríguez-Ortega, Alberto Becerra-Tome, Pablo Arancibia, Fernando Gallego-Donoso +35 more
benchmark similarity 0.66
Abstract · 91 pages, 7 figures, 33 tables (9 in the main text, 23 in Appendix A, and 1 in Appendix B)

Background: Cardiovascular care generates large volumes of clinical free-text documentation in local languages. However, clinical natural language processing (NLP) resources remain concentrated in English, and no existing benchmark is cardiology-specific, multilingual, and broad in entity coverage. Methods: We present two contributions. The first is CardioCCC, a corpus of 508 cardiology case reports originally published in Spanish and extended to Czech, Dutch, English, Italian, Romanian, and Swedish through machine translation, annotation projection, and clinician review, with annotations covering diseases, symptoms, procedures, and medications. The second is CardioLM, comprising CardioBERTa, a set of language-specific encoders obtained by continued pretraining on cardiology and biomedical corpora, and CardioNER, a set of named entity recognition (NER) models fine-tuned on CardioCCC. Results: Cardiology-specific pretraining reduced pseudo-perplexity by up to a factor of eight, yet changed strict span-level F1 by at most 0.04, with benefits concentrated in languages whose backbones lacked biomedical coverage. The jointly trained multilingual XLM-RoBERTa-large models achieved the best strict F1 in nearly every language and entity type, exceeding the strongest monolingual system by up to 0.13 F1. A large share of residual errors concerned boundary detection: relaxed matching recovered 0.10-0.23 F1 for disease, procedure, and symptom, but only 0.01-0.07 for medication. Clinicians rated CardioNER well above a rule- and dictionary-based baseline, with the mean rating across entity types rising from 26% to 73%. Conclusions: Specialty-specific pretraining is not the decisive factor for downstream entity recognition, whereas multilingual joint training yields the strongest results in nearly all settings and a simpler deployment path for multi-country clinical information extraction.

0.24

IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for Electrocardiogram

cs.AI ·2026-10-20 ·Huynh Dang Nguyen, Trong-Thang Pham, Anh-Thuan Do, Phuong-Nhi Dinh, Brijesh Patel +2 more
published similarity 0.65
Abstract · Accepted in WACV 2027

Electrocardiography (ECG) is a cornerstone of cardiac diagnosis, yet most machine learning methods for ECG analysis lack interpretability, limiting their clinical adoption. We present IECG, a weakly-supervised ECG foundation model that jointly performs diagnostic classification and abnormality localization without requiring manual abnormal region annotations, overcoming a long-standing bottleneck in interpretable ECG learning. Central to IECG is a weakly-supervised attention strategy that explicitly incorporates clinical priors by deriving abnormality heatmap pseudo-labels from established ECG clinical knowledge. These pseudo-labels guide the model's CLS-token attention through a KL-divergence loss, encouraging it to focus on diagnostically relevant waveform regions. During pretraining, IECG is jointly optimized with clinically guided attention supervision, ECG-text contrastive alignment, and report captioning objectives, enabling it to learn rich multimodal representations while producing localized waveform evidence. By explicitly aggregating features from clinically guided attention regions, IECG grounds its diagnostic predictions in interpretable waveform evidence without sacrificing classification performance. Extensive experiments demonstrate that IECG achieves state-of-the-art abnormal region localization while maintaining strong classification performance, advancing trustworthy foundation models for ECG analysis.

0.31

TRACE: Expert-Aligned ECG Representation Learning with Rigorous Benchmarking and Real-World Validation in Acute Cardiac Care

cs.LG cs.AI ·2026-09-28 ·Lovely Yeswanth Panchumarthi, Andrew Lu, Saurabh Kataria, Delgersuren Bold, Minxiao Wang +9 more
benchmark similarity 0.64
Abstract · 42 pages, 4 figures and 1 table

TRACE (Text-Reinforced Analysis of Cardio ECGs) is a multimodal electrocardiogram (ECG) representation model that learns clinically grounded signal embeddings for downstream cardiac classification. It is designed to address the limitations of existing CLIP-style training, which often struggles with noisy clinical text and fails to leverage the complementary strengths of unimodal (from ECG) and cross-modal (between ECG and matched cardiologist reports) learning. To bridge this gap, we propose a hybrid architecture that jointly learns unimodal and cross-modal representations via uncertainty-weighted multi-task learning while utilizing an LLM-based pipeline to extract high-fidelity findings from cardiologist reports. We evaluate TRACE across a spectrum of clinical urgency, establishing robust performance on public benchmarks for arrhythmia classification and structural abnormalities relative to existing unimodal and multimodal ECG models. To demonstrate real-world utility, we further validate the model on acute coronary occlusion (ACO), where the prevailing ST-elevation criteria miss 25-34% of true occlusions. Utilizing a large private ACO dataset with expert-annotated ground truth, TRACE significantly outperforms real-world clinical practice, yielding a 19.0% increase in sensitivity or a 62.6% reduction in false positive rates at the clinical baseline. This extensive evaluation confirms that TRACE delivers both strong performance on benchmark tasks and tangible clinical impact in the most acute, high-risk cardiac scenarios.

0.11

RAG-TRACE: Tracing Measurement Evidence and Diagnostic Completeness in AI-Generated ECG Reports

cs.CL ·2026-11-01 ·Elyas Irankhah, Shahed Salehzehi, Parisa Hosseini
code/data similarity 0.64
Abstract · Code and study materials available at https://github.com/Elyasirankhah/RAG-TRACE

Purpose: Retrieval-augmented generation (RAG) can introduce electrocardiogram (ECG) criteria that lack patient-specific measurement support. This study evaluates the reliability of retrieved diagnostic criteria in AI-generated ECG reports. Methods: We analyzed 1,083 human-validated PTB-XL patient records using a library of 47 criteria cards, including 33 without numeric verification rules. Language models generated structured reports with and without retrieval. Criterion applicability was evaluated using Marquette 12SL measurements, with independent assessment using Uni-G and comparison against expert-validated diagnostic labels. Results: Keyword retrieval introduced untestable or measurement-disconfirmed criteria in 46.8% of GPT-4.1-mini reports. A deterministic verification rule withdrew 647 criterion applications, including 639 without numeric checks, while preserving 268 of 269 applications independently supported by Uni-G. Restricting retrieval to 14 testable criteria reduced the initial unsupported-criterion rate to 13.8%. Under matched instructions and an identical output schema, retrieval increased unsupported-criterion reports from 17.4% to 31.1%, while hypertrophy recall remained unchanged at 62.6%. Conclusion: These findings identify a fundamental limitation of retrieval-based clinical report generation: retrieved criteria do not necessarily provide valid patient-specific evidence. Measurement-based verification can reduce unsupported criterion applications, but diagnostic validity requires independent assessment.

0.41

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.64
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.32

Knowledge-Enriched Structured EHR Features for 30-Day Hospital Readmission Prediction on MIMIC-IV

cs.LG q-bio.QM ·2026-09-14 ·Mohamad Najafi, Hongyun Fu, Mathias Brochhausen, Jian Wu, Yaohang Li
published similarity 0.63
Abstract · 15 pages, 3 figures. Accepted at SDSC 2026 Mid-Atlantic

Recent approaches to 30-day hospital readmission prediction rely on pre-trained language models applied to discharge summaries. Although these methods achieve strong performance, they depend on the availability of clinical notes, incur substantial computational costs, and yield representations that lack interpretability. We propose a knowledge-enriched feature representation that augments structured Electronic Health Record (EHR) data with four medical knowledge sources: disease ontology mapping, procedure classification, drug ingredient vocabulary, and organ system laboratory aggregation, without using clinical notes. Each feature dimension corresponds to a named clinical concept, yielding a sparse and interpretable patient representation. The approach is evaluated with six classifiers on a MIMIC-IV v2.2 cohort. Under 20-fold cross-validation, the best configuration achieves an AUROC of 0.743. This performance is comparable to that of previously reported methods on this dataset, including both those using only structured data and those incorporating clinical notes, while requiring considerably less computational cost. Interpretability analysis shows that demographics, organ system labs, drug ingredient features, and first-level ontology disease categories drive prediction, while deeper hierarchy levels contribute negligibly. These findings indicate that knowledge-enriched structured features offer a competitive and efficient alternative to embeddings from clinical notes for 30-day readmission prediction.

0.25

Making Clinical Language Models Auditable: Concept-Guided Fine-Tuning for Robust Prediction

cs.CL cs.AI ·2026-08-27 ·Jin Mu, Guanhua Chen
top venue similarity 0.62
Abstract

Clinical language models can achieve strong in-hospital accuracy yet fail under deployment shifts because they exploit note-specific artifacts (e.g., templates, separators, boilerplate) that do not reflect patient state. We propose CAST (Concept-guided Artifact Suppression Tuning), an SAE-based framework for auditable clinical text classification. CAST uses Sparse Autoencoders to expose sparse, human-auditable features from intermediate Transformer activations, labels SAE latents with an LLM-assisted interpretation pipeline and ICD-10 retrieval constraints, suppresses verified artifact latents via residual subtraction during fine-tuning, and provides post-hoc per-concept attributions for auditing model decisions. On MIMIC-IV discharge-note mortality prediction, CAST improves over its corresponding fine-tuned encoder baselines and remains competitive with strong LLM baselines, while producing a feature-level audit trail of the clinical concepts that support each prediction and the artifact concepts suppressed during training.

0.44