CS Paper Radar

Capturing Cardiac Cyclicity through Phase-Equivariant Self-Supervised Learning

Blaise Delaney, Dominic Dootson, Juan Jose Juan Castella, Salil Patel, Andrew Pfaff, Yuji Xing, Jonny Hancox, Karin Sevegnani

cs.LG ·submitted 2026-08-21 14:23 UTC · v1

Abstract

The cyclic structure of physiological processes offers a natural prior for self-supervised representation learning, and the cardiac cycle provides a particularly well-defined setting in which to exploit it. We derive a phase-equivariant self-supervised objective and introduce Winder, a joint-embedding architecture that organises representations into phase-invariant coordinates and phase-rotating harmonic subspaces. Its transport operator is fixed and closed-form, derived from the cycle's geometry rather than learned, and adds no parameters. Evaluated on PTB-XL under a frozen linear-probe protocol, Winder attains diagnostic accuracy within the range reported by state-of-the-art self-supervised methods at a ~1 M parameter footprint, while exhibiting phase-equivariant latent geometry. These findings demonstrate that explicitly encoding cardiac-phase symmetry can preserve diagnostically useful information while yielding a latent geometry that is legible, parameter-efficient, and directly tied to a measurable physiological quantity.

Closest papers

Nearest neighbours by meaning across the whole index.

Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits

cs.CV ·2026-09-10 ·John Bonnici, Matthew Baugh, Aleksandra Kulbaka, Sarah Cechnicka, Bernhard Kainz +1 more
publishedcode/data similarity 0.81
Abstract · Accepted for oral presentation at the ASMUS workshop at MICCAI 2026

Accurate identification of end-diastole (ED) and end-systole (ES) in echocardiography underpins the quantification of ventricular function, yet manual selection of these key frames is subjective and introduces clinically significant inter-operator variability. Recent self-supervised methods either prescribe strict periodic trajectories or learn an unconstrained low-dimensional motion subspace from reconstruction or registration objectives. The former offers interpretability but imposes restrictive assumptions on temporal progression, whereas the latter leaves cardiac phase implicit and ED/ES must be recovered through post-hoc geometric processing of the learned trajectory. We translate the physiological observation that cardiac phase is a one-dimensional signal into a prior by constraining the latent motion component to a single-parameter latent orbit, i.e., a global linear trajectory in latent space indexed by a bounded scalar phase variable. Mapping this variable through a sinusoidal nonlinearity yields an oscillatory motion signal with consistent temporal ordering, enabling direct identification of ED and ES from the learned phase signal. This inductive bias allows the model to capture an interpretable representation of the cardiac cycle, while maintaining flexibility to capture irregular heartbeats. Trained on EchoNet-Dynamic without annotations, our minimal single-parameter cardiac phase model learns an effective latent orbit, significantly improves upon the previous state of the art in ED localisation and matches it in ES localisation while using a more constrained representation and fewer training epochs. This demonstrates that a principled physiological inductive bias can match or exceed the performance of more complex representations. Code is available at: https://github.com/BonniciJ/OrbitalEcho/

0.31

Cyclostationary Phase Conditioning for Medical Time Series Diffusion

cs.LG cs.AIeess.SP ·2026-09-28 ·Samuel Ruiperez-Campillo, Michele Copetti, Jorge da Silva Goncalves, Sonia Laguna, Thomas Hofmann +1 more
similarity 0.67
Abstract · 43 pages, 16 figures, 21 tables

Many physiological time series, such as cardiac and brain recordings, exhibit cyclostationarity: their statistics vary periodically with an underlying cycle phase. Corruption from motion, poor contact, and physiological interference obscures morphology needed for diagnosis, making signal restoration essential. Existing diffusion approaches condition on corrupted observations alone and must learn cyclic structure implicitly. We instead propose two inductive biases which encode cyclostationarity: a shift-covariant wavelet representation and dense per-sample phase conditioning inferred from the corrupted input. We further introduce a training-free cyclostationarity index that quantifies phase structure and predicts when phase conditioning will help. Finally, we propose antithetic coupling of reverse trajectories to reduce sampling variance while achieving comparable performance with fivefold fewer network evaluations. Across modalities, our results show that explicitly encoding measurable cyclic structure improves physiological time-series restoration.

0.45

One Frame, Full Heartbeat: ECG-Free Cardiac Cine MRI Synthesis via Phase-Conditioned Flow Matching

cs.CV ·2026-10-07 ·Shiyi Wang, Ruochen Sun, Peirong Liu, Xiang Li, Fangxu Xing
benchmark similarity 0.65
Abstract

Cine cardiovascular magnetic resonance (CMR) analysis relies on multi-frame sequences capturing the full cardiac cycle. However, standard multi-frame acquisition depends heavily on electrocardiogram (ECG) gating and repeated breath-holds, posing challenges in uncooperative populations, resource-limited settings, and temporally corrupted datasets. Existing methods that synthesize full cardiac sequences either rely on explicit ECG signals to parameterize myocardium function, or employ deformable registration without physiological constraints, failing to faithfully reproduce clinically relevant dynamic metrics such as ejection fraction (EF) and ventricular contraction magnitude. We present PhaseFlow, a unified generative framework that overcomes both limitations. PhaseFlow estimates a non-linear cardiac phase signal directly from the input sequence via a segmentation-derived left-ventricular (LV) area curve, capturing the asymmetric dynamics of systole and diastole without any ECG dependency. At inference, this phase signal is provided by a pathology-specific template, informing phase-specific frame generation. A rectified flow model conditioned on the phase and slice position synthesizes the full cardiac motion trajectory in the latent space, decoded into a diffeomorphic displacement field that warps end-diastole pixel intensities directly, eliminating the reconstruction blur often accompanying the variational autoencoder. On the ACDC benchmark, PhaseFlow achieves superior physiological fidelity and image realism, with best LV volume curve $R^2$, structural similarity (SSIM) and generative quality (FID) among all baselines. Ablation studies confirm that each proposed component contributes measurably to the overall performance.

0.15

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

cs.LG eess.SP ·2026-08-13 ·Ahmed Sameh, Ramzi Al-Sharawi, Yogatheesan Varatharajah
publishedcode/data similarity 0.64
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026). 6 pages, 2 figures…

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.

0.41

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

cs.LG eess.IVstat.ML ·2026-08-13 ·Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu +1 more
similarity 0.63
Abstract

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.

0.42

Phenomenon-Graph JEPA: Label-Efficient Representation Learning for Contactless Cardiorespiratory Sensing

cs.LG cs.ET ·2026-09-26 ·Constantino Álvarez Casado, Nhi Nguyen, Mohammad Rakibur Rahman, Le Nguyen, Manuel Lage Cañellas +2 more
similarity 0.63
Abstract · 9 pages, 4 figures, 7 tables, 24 numbered equations. Extended version of a conference submission, with additional methodological details, im…

Millimeter-wave (mmWave) radar and RGB-D cameras can record cardiac and respiratory waveforms continuously and without contact, but labeled recordings remain scarce because every label requires a supervised acquisition session. Self-supervised pretraining can exploit the unlabeled signals, yet contrastive methods depend on signal transformations and negative pairs whose validity is uncertain for cardiorespiratory data, where time warping changes breathing rate and distant windows can share the same physiological state. We present Phenomenon-Graph JEPA, a joint-embedding predictive architecture that learns from four processed one-dimensional streams without negative pairs or synthetic augmentation in its base configuration. Each stream is encoded by a temporal convolutional branch and a band-limited spectral branch. During pretraining, the model predicts stopped target embeddings along typed edges, which connect streams assigned to the same physiological phenomenon, and forward in time within a state episode. We treat this physiological typing as a testable hypothesis and compare it with wrong-edge and all-pairs prediction graphs. In the OMuSense-23 dataset, pretraining improves label-efficiency area over matched supervised training by 3.91 percentage points (95% interval 2.08 to 5.80, Holm-adjusted p = 0.006), and by 3.74 points under a second configuration evaluated on the same test participants. However, the wrong-edge and all-pairs controls do not establish a benefit from physiological typing. Optional Takens-inspired delay coordinates improve a validation comparison with learned history, whereas two wrist-only WESAD protocols do not establish a pretraining advantage. The study therefore separates the measured benefit of predictive representations from the physiological prior used to organize their training.

0.20

TRACE: Tractable Routing Autoencoder for Clinical ECG

cs.LG ·2026-09-20 ·Shunbo Jia, Runze Ma, Haonan Lyu, Haijin Zhang, Qiang Yang +1 more
similarity 0.63
Abstract · 20 pages, 7 figures, 7 tables

Deep learning has advanced automated electrocardiogram (ECG) diagnosis, but the field's most accurate models, foundation models pretrained on millions of recordings, are not decision-pathway auditable: a clinician cannot trace a diagnosis to a physiological pathway or intervene on one. We propose TRACE, a Tractable Routing Autoencoder for Clinical ECG, whose 32-dimensional clinical latent space is specified in advance from domain knowledge rather than discovered by optimization. TRACE partitions this space into perfusion, structure, and conduction subspaces, routes each to its own diagnostic head by design, regularizes the partition with an orthogonality penalty, and reconstructs the ECG through a decoder that permits latent perturbation. On PTB-XL and Georgia, TRACE exceeds unconstrained classifiers and stays ahead of an ECG foundation model pretrained on ten million recordings, evaluated by linear probe on frozen features, at roughly an eighth of the parameter count. On the nine-label CPSC2018 cohort, which carries no structural class, the framework transfers with only the routing table re-specified to a perfusion/rhythm/conduction partition. Joint probe, erasure, and perturbation analyses verify the routing contract, and perturbing the depolarization and repolarization pathways modulates the reconstructed waveform. Removing the specified partition and its orthogonality penalty costs 1.70 AUC and 11.30 macro-F1 points on PTB-XL, and 2.76 AUC and 16.92 macro-F1 points on Georgia. A capacity-matched permutation control places arbitrary assignments within 0.34 AUC points of the ontology routing and leaves macro-F1 statistically level (p=0.619): the ontology supplies decision-pathway auditability at no macro-F1 cost.

0.32

PI-AMFM: Permutation-Invariant Learning for Variable-Cardinality AM-FM Mode Decomposition in Biomedical Signal Analysis

eess.SP cs.LG ·2026-09-30 ·Youngsun Kong, Ki H. Chon
similarity 0.62
Abstract · 5 pages, 3 figures

Physiological recordings often contain nonstationary oscillatory components whose number and dynamics vary across signals. Amplitude- and frequency-modulated (AM-FM) representations are well suited to characterizing such dynamics and have shown broad utility in biomedical signal analysis. Recent approaches have incorporated neural networks to learn mode decomposition patterns from data, but component cardinality is often predefined or determined through separate stopping or selection mechanisms. We propose a permutation-invariant neural framework for variable-cardinality AM-FM mode decomposition (PI-AMFM). PI-AMFM combines a multiscale temporal encoder, Mamba backbone, and component-presence estimation, with permutation-invariant Hungarian matching during training. On synthetic AM-FM signals, PI-AMFM achieved lower decomposition, instantaneous-frequency, reconstruction, and mode-count errors than the compared methods while preserving the overall trajectory pattern in a crossing-chirp example. On photoplethysmographic recordings, recovered modes captured cardiac and respiratory dynamics despite training only on synthetic signals. These results support the feasibility of PI-AMFM for variable-cardinality decomposition of nonstationary biomedical signals.

0.29