CS Paper Radar

TRACE: Tractable Routing Autoencoder for Clinical ECG

Shunbo Jia, Runze Ma, Haonan Lyu, Haijin Zhang, Qiang Yang, Caizhi Liao

cs.LG ·submitted 2026-09-20 08:41 UTC · v1

Abstract

Deep learning has advanced automated electrocardiogram (ECG) diagnosis, but the field's most accurate models, foundation models pretrained on millions of recordings, are not decision-pathway auditable: a clinician cannot trace a diagnosis to a physiological pathway or intervene on one. We propose TRACE, a Tractable Routing Autoencoder for Clinical ECG, whose 32-dimensional clinical latent space is specified in advance from domain knowledge rather than discovered by optimization. TRACE partitions this space into perfusion, structure, and conduction subspaces, routes each to its own diagnostic head by design, regularizes the partition with an orthogonality penalty, and reconstructs the ECG through a decoder that permits latent perturbation. On PTB-XL and Georgia, TRACE exceeds unconstrained classifiers and stays ahead of an ECG foundation model pretrained on ten million recordings, evaluated by linear probe on frozen features, at roughly an eighth of the parameter count. On the nine-label CPSC2018 cohort, which carries no structural class, the framework transfers with only the routing table re-specified to a perfusion/rhythm/conduction partition. Joint probe, erasure, and perturbation analyses verify the routing contract, and perturbing the depolarization and repolarization pathways modulates the reconstructed waveform. Removing the specified partition and its orthogonality penalty costs 1.70 AUC and 11.30 macro-F1 points on PTB-XL, and 2.76 AUC and 16.92 macro-F1 points on Georgia. A capacity-matched permutation control places arbitrary assignments within 0.34 AUC points of the ontology routing and leaves macro-F1 statistically level (p=0.619): the ontology supplies decision-pathway auditability at no macro-F1 cost.

Comment
20 pages, 7 figures, 7 tables

Closest papers

Nearest neighbours by meaning across the whole index.

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.68
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

cs.LG cs.AIcs.CVeess.SP ·2026-10-06 ·Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim +4 more
benchmarkcode/data similarity 0.67
Abstract · 20 pages, 5 figures. First two authors contributed equally

Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

0.30

QECGBERT: A Scalable ECG Foundation Model Based on Self-Supervised Language Learning via VQ-VAE Waveform Tokenization

cs.LG cs.AI ·2026-10-25 ·Aruna Mohan, Burcu Ozek, Or Zilbershot, Fatemeh Afghah
similarity 0.67
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

AI foundation models play a pivotal role in advancing heart disease diagnosis from electrocardiogram (ECG) data, particularly for rare diseases where the lack of sufficient labeled data hinders supervised learning. However, most self-supervised learning methods treat ECGs as generic sequence or image data without exploiting underlying physiological structure. To address this limitation, we propose QECGBERT, a self-supervised ECG language model that explicitly encodes physiological semantics by tokenizing the P, QRS, T, and isoelectric background waveforms. Vector-quantized variational autoencoder (VQ-VAE) tokenization is applied to each 12-lead ECG, with tokens enriched by continuous waveform features to preserve morphology lost during quantization without increasing sequence length. This design enables compact BERT masked language modeling with short sequences, improving scalability and reducing computational cost relative to long-sequence approaches. QECGBERT applies BERT pre-training to the MIMIC-IV dataset containing over 800,000 unlabeled ECG recordings, and fine-tuning on labeled PTB-XL, CPSC2018, and Chapman--Shaoxing--Ningbo datasets for evaluation. The results demonstrate that QECGBERT achieves comparable or superior performance to published benchmarks, offering a scalable, physiologically aware approach to ECG foundation modeling for cardiac diagnosis.

0.22

Atrial Fibrillation Detection with Arbitrary Leads via a Codebook-Based Reconstruction-Classification Framework

cs.LG q-bio.QM ·2026-08-19 ·Hongtao Li, Jia Wei, Guoyao Li, Yuchen Lei, Guangnian Ma +4 more
benchmark similarity 0.67
Abstract

\textbf{Background and Objective}: Reliable atrial fibrillation (AF) detection from electrocardiogram (ECG) signals remains challenging in real-world clinical settings due to variable lead configurations, cross-dataset domain shifts, and pervasive physiological and technical artifacts. So we develop a robust and generalizable deep learning model for accurate AF detection.\\ \textbf{Methods}: We propose the Dual-Codebook Graph Collaborative Network (DCGCNet), a novel end-to-end vector-quantized variational autoencoder that jointly performs AF classification and ECG reconstruction. DCGCNet introduces two key components: (1) a Local-Global Contrastive Module for learning noise-invariant representations, and (2) an Adaptive Codebook Vector Quantizer that dynamically refines codebook prototypes to better align with input data distributions, thereby preventing codebook collapse and enhancing generalization.\\ \textbf{Results}: DCGCNet achieves state-of-the-art performance in standard intra-dataset 12-lead evaluation and demonstrates exceptional cross-dataset generalization across seven diverse settings, consistently attaining AUC > 0.98 in all cases. Furthermore, it maintains high diagnostic accuracy under realistic noisy conditions, including baseline wander, powerline interference, and EMG artifacts.\\ \textbf{Conclusions}: DCGCNet establishes a new benchmark for robust, generalizable, and noise-resilient AF detection, showing strong potential for deployment in real-world clinical environments.

0.15

Same path, different walk: a mechanistic comparison of looped and stacked transformer encoders on 12-lead ECG

cs.LG math.DS ·2026-09-14 ·Pawel Olszowiec, Michal Byra, Grzegorz Gruszczynski, Grzegorz Stefanski, Alberto Presta
similarity 0.66
Abstract · 5 pages, 7 figures

Recurrent Transformers reusing their weights rather than stacking $L$ distinct layers are becoming widely adopted due to their parameter efficiency [1,2,3]. However, the exact representational and dynamical differences between looped and stacked architectures remain uncharacterized. This paper presents a controlled study on the example of bViT model [1] applying one weight-tied block $L$ times. We train two models: bViT and standard ViT [4] on 12-lead electrocardiogram (ECG) classification tasks from the PTB-XL dataset under identical training protocols. Despite an $8.9\times$ parameter reduction, bViT achieves accuracy parity with ViT. Geometric similarity metrics demonstrate that both architectures construct comparable latent representations in an equivalent canonical order. Crucially, their dynamics differ: bViT exhibits smaller step sizes and inter-patient sensitivity, as well as near-neutral behavior away from the data manifold, whereas ViT exhibits collapsing dimensionality of representations and out-of-distribution feature expansion.

0.54

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

cs.LG ·2026-10-06 ·Robert A. Lewis, I-Min Chiu, Kyle Verrier, Karthik Jayaraman Raghuram, Francoise Marvel +5 more
similarity 0.66
Abstract · Andrew C. Miller, Joseph Futoma: equal contribution. 52 pages, 4 figures, 20 tables, including supplementary information

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.

0.32

TransECG-SSL: Hybrid Self-Supervised Representation Learning for ECG Arrhythmia Classification

cs.LG ·2026-10-26 ·Ahtisham Ayyub, Fasih Haider, Muhammad Rehan Usman, Saturnino Luz, Christos Politis +1 more
similarity 0.66
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics

Cross-dataset generalisation remains a major challenge for automated electrocardiogram (ECG) arrhythmia classification because of differences in patient populations, acquisition protocols, annotation practices, and class distributions. Learning representations that remain informative across independent datasets could reduce reliance on dataset-specific labelled data. We propose TransECG-SSL, a self-supervised framework for transferable heartbeat representation learning from unlabelled ECG data. A Transformer encoder is pretrained using a hybrid objective combining masked signal reconstruction and contrastive learning, then frozen and evaluated by linear probing under patient-disjoint evaluation. Experiments across three public ECG databases and seven source--target settings show that Hybrid SSL consistently outperforms randomly initialised Transformers and achieves higher balanced accuracy than architecture-matched source-supervised pretraining. Reconstruction-only SSL remains competitive with Hybrid SSL, whereas contrastive-only pretraining performs substantially worse, highlighting the importance of masked reconstruction for transferability. Cross-dataset transfer nevertheless reduces balanced accuracy relative to target-specific self-supervised pretraining, while minority arrhythmia classes remain challenging under severe class imbalance. These findings demonstrate the potential of label-efficient self-supervised learning for cross-dataset ECG representation transfer while highlighting persistent limitations from domain shift and class imbalance.

0.24

TRACE: Expert-Aligned ECG Representation Learning with Rigorous Benchmarking and Real-World Validation in Acute Cardiac Care

cs.LG cs.AI ·2026-09-28 ·Lovely Yeswanth Panchumarthi, Andrew Lu, Saurabh Kataria, Delgersuren Bold, Minxiao Wang +9 more
benchmark similarity 0.66
Abstract · 42 pages, 4 figures and 1 table

TRACE (Text-Reinforced Analysis of Cardio ECGs) is a multimodal electrocardiogram (ECG) representation model that learns clinically grounded signal embeddings for downstream cardiac classification. It is designed to address the limitations of existing CLIP-style training, which often struggles with noisy clinical text and fails to leverage the complementary strengths of unimodal (from ECG) and cross-modal (between ECG and matched cardiologist reports) learning. To bridge this gap, we propose a hybrid architecture that jointly learns unimodal and cross-modal representations via uncertainty-weighted multi-task learning while utilizing an LLM-based pipeline to extract high-fidelity findings from cardiologist reports. We evaluate TRACE across a spectrum of clinical urgency, establishing robust performance on public benchmarks for arrhythmia classification and structural abnormalities relative to existing unimodal and multimodal ECG models. To demonstrate real-world utility, we further validate the model on acute coronary occlusion (ACO), where the prevailing ST-elevation criteria miss 25-34% of true occlusions. Utilizing a large private ACO dataset with expert-annotated ground truth, TRACE significantly outperforms real-world clinical practice, yielding a 19.0% increase in sensitivity or a 62.6% reduction in false positive rates at the clinical baseline. This extensive evaluation confirms that TRACE delivers both strong performance on benchmark tasks and tangible clinical impact in the most acute, high-risk cardiac scenarios.

0.11