CS Paper Radar

Phase-Aligned Finite-Fourier Periodic Deformation for 4D Medical Image Interpolation

Haojin Li, Hengzhuo Wang, Zhiheng Ma, Mingyang Ou, Heng Li, Jiang Liu

cs.CV ·submitted 2026-08-25 03:34 UTC · v1
top venue

Abstract

4D medical image interpolation aims to recover missing volumes from sparsely observed time points and is important for dynamic anatomical analysis in applications such as cardiac MRI and thoracic CT, where motion is often repetitive or near-periodic over clinically relevant intervals. A key challenge is that this structure is not always encoded directly in deformation representations for interpolation. In addition, physiological motion is often non-uniform, so equal temporal intervals do not necessarily correspond to equal amounts of anatomical change. To address these issues, we formulate interpolation as learning a continuous deformation process with a phase-structured prior. Given two endpoint volumes, we parameterize a phase-conditioned velocity field with a finite Fourier basis, which embeds near-periodic motion patterns directly into the deformation space and supports continuous querying at arbitrary target times. We further introduce a phase-aligned temporal reparameterization that maps normalized within-interval time to a latent motion phase according to deformation variation intensity, thereby better modeling non-uniform motion progression. Intermediate volumes are then synthesized by continuously warping both endpoints, followed by bidirectional fusion and lightweight residual refinement. Experiments on ACDC and 4D-Lung show that the proposed method achieves state-of-the-art performance over existing baselines while producing anatomically plausible and coherent intermediate volumes from sparse observations.

Comment
ACMMM 2026 accepted

Closest papers

Nearest neighbours by meaning across the whole index.

Low-Rank Velocity Fields as a Structural Prior for Unsupervised 4D Medical Image Interpolation

cs.CV ·2026-08-25 ·Haojin Li, Hengzhuo Wang, Chang Liu, Zhiheng Ma, Heng Li +1 more
top venue similarity 0.79
Abstract · MICCAI 2026

Endpoint-only unsupervised 4D medical image interpolation synthesizes intermediate volumes from sparsely sampled sequences with only the start and end volumes available for training; however, this weakly constrained setting often yields intermediates with unstable boundaries and non-physiological motion, limiting interpretability and downstream analysis. We propose low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts. To capture global coordination and local non-rigid details, we model motion in a coarse-to-fine multi-scale scheme and compose scale-wise deformations at inference to synthesize volumes at arbitrary times. We further provide a theoretical analysis showing that, under Tucker parameterization, low-rank parameters control the smoothness energy of the velocity field, explaining why low-rank modeling promotes smoother motion. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance, remaining competitive with methods trained with intermediate-frame supervision, and producing intermediates with improved structural coherence and more stable anatomical contours.

0.54

Learning a Motion Manifold to Constrain Ambiguity in Unsupervised 4D Medical Image Interpolation

cs.CV ·2026-10-29 ·Haojin Li, Huazhu Fu, Heng Li, Jiang Liu
similarity 0.75
Abstract

Unsupervised 4D medical image interpolation reconstructs intermediate anatomical states from temporally sparse observations without intermediate supervision. Distinct motion fields may attain comparable endpoint agreement while producing different intermediate anatomy, giving rise to motion ambiguity. This ambiguity is difficult to constrain when many independently adjustable motion variables must be estimated from the observed endpoints. We develop a framework that learns a motion manifold to restrict candidate motion fields while retaining sample-specific variation. Cross-Sample Spectral Basis Learning extracts recurring motion structure from endpoint-derived dense estimates and encodes it in a shared spectral basis. Sample-Conditioned Cayley Basis Reorientation uses predicted motion coordinates to rotate the effective motion directions for each endpoint pair without increasing the number of independent coordinates. Their composition defines a nonlinear family of complete velocity fields across endpoint pairs, accommodating anatomical and motion-state differences within a restricted representation. Integrating each predicted field supports bidirectional reconstruction at arbitrary intermediate times. Theoretical analysis establishes sufficient conditions under which endpoint observations distinguish nearby motions within the learned family. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance among the evaluated methods trained without intermediate volumes and competitive results against methods using intermediate supervision.

0.09

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.71
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.16

Coronary Mask Guided Registration for Continuous Time 4D Cardiac CT Dataset Construction

eess.IV cs.CV ·2026-08-28 ·Yuang Wang, Shuo Wang, Changyu Chen, Dufan Wu, Pengfei Jin +10 more
hot direction similarity 0.68
Abstract · 12 pages, 7 figures. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after w…

Objective: Clinical cardiac CT multiphase reconstructions generally provide acceptable image quality in end-diastole (ED) or end-systole (ES) phases, but in other phases may exhibit motion artifacts, especially in the right coronary artery (RCA). This limits ground-truth availability in 4D cardiac CT imaging research. We aim to construct a 4D cardiac CT dataset that is generally suitable to serve as pseudo ground truth. Methods: We propose Coronary Mask Guided Registration (CMGR) to produce a motion-preserved, artifact-reduced, and continuous-time 4D cardiac CT sequence from the clinical multiphase reconstruction of each patient. For artifact reduction, CMGR uses the ED or ES phase as the reference phase and warps the reference volume with deformation fields to produce the sequence. For motion preservation, CMGR registers the reference phase to each non-reference phase of the multiphase reconstruction. To capture the motion of both the RCA and other cardiac structures in each registration, CMGR regularizes RCA masks and incorporates them into image-domain registration. Time-continuity is achieved by interpolating the deformation fields for non-reference phases to arbitrary times. Results: CMGR outperformed representative image-domain registration methods in capturing RCA motion and providing reasonable RCA shape, and showed competitive performance in capturing whole-heart motion. Additionally, CMGR reduced motion artifacts from clinical multiphase reconstructions, and intermediate CMGR frames generally provided plausible transitions between discrete cardiac phases. Conclusion: CMGR provides an effective approach for constructing continuous-time 4D cardiac CT datasets. Significance: The dataset can be used in system design simulations and in reconstruction algorithm development, thereby facilitating advances in cardiac CT imaging.

0.33

CardioTrace: Motion-Aware Cine Synthesis via Coupled Tracing and Segmentation

cs.CV ·2026-11-13 ·Zhi Chen, Le Zhang
hot direction similarity 0.67
Abstract

Cardiac cine MRI provides time-resolved visualization of cardiac motion and is essential for evaluating ventricular function and anatomy. In routine clinical acquisition, however, cine sequences are frequently temporally sparse or degraded by arrhythmia, motion, and scan-time constraints, which can hinder reliable quantification and downstream analysis. We present CardioTrace, a motion-aware cine synthesis framework that generates a full cardiac cine sequence from limited input while explicitly modeling and tracing cardiac motion. CardioTrace couples two complementary pathways: a pixel-translation branch that directly predicts cine frames in a residual formulation, and a flow-field branch that estimates time-resolved deformation fields from a reference phase to provide interpretable motion correspondences across frames. To further preserve anatomical plausibility, a segmentation branch supervises clinically meaningful cardiac structures at key phases, and a cross-branch consistency objective encourages the synthesized appearance dynamics to follow the explicit motion guidance, mitigating temporal drift and unrealistic shape transitions over long sequences. The framework also supports prompt-style conditioning to incorporate auxiliary patient or acquisition information, improving robustness across heterogeneous multi-center data. Experiments on public cardiac cine MRI datasets demonstrate that CardioTrace improves perceptual quality and temporal coherence over representative GAN- and diffusion-based baselines, while better preserving ventricular morphology throughout the cardiac cycle. \textit{Our codes are available after review}.

0.17

Two-Parameter Flow Map Learning for Continuous-Time Diffeomorphic Image Registration

cs.CV ·2026-09-09 ·Mohammadjavad Matinkia, Nilanjan Ray
top venue similarity 0.67
Abstract · Published at European Conference on Computer Vision (ECCV), 2026

Diffeomorphic image registration is central to medical image analysis, enabling anatomically consistent alignment across subjects. Most learning-based diffeomorphic methods model autonomous ODEs(ordinary differential equations) by parameterizing a stationary velocity field and recovering deformations via scaling-and-squaring. While non-autonomous ODEs with time-dependent velocities increase expressiveness, existing approaches rely on numerical integration to implicitly enforce flow structure that entangles model expressiveness with discretization accuracy. We propose a framework to directly learn the continuous-time solution of a non-autonomous ODE formulated as a two-parameterflow map. By enforcing cocycle consistency, a fundamental structural property of time-varying flows, we learn the flow maps without time discretization and velocity integration during training. The framework recovers diffeomorphic mappings at inference using a small number of compositions. Our proposed framework seamlessly incorporates standard registration backbones and improves alignment accuracy consistently across nine datasets while preserving diffeomorphic structure. Notably, the proposed method achieves an average Dice improvement of 2.1% on brain MRI benchmarks, a 12% TRE reduction on lung CT, and a 2.6% Dice gain on cardiac MRI and ultrasound datasets.

0.46

One Frame, Full Heartbeat: ECG-Free Cardiac Cine MRI Synthesis via Phase-Conditioned Flow Matching

cs.CV ·2026-10-07 ·Shiyi Wang, Ruochen Sun, Peirong Liu, Xiang Li, Fangxu Xing
benchmark similarity 0.66
Abstract

Cine cardiovascular magnetic resonance (CMR) analysis relies on multi-frame sequences capturing the full cardiac cycle. However, standard multi-frame acquisition depends heavily on electrocardiogram (ECG) gating and repeated breath-holds, posing challenges in uncooperative populations, resource-limited settings, and temporally corrupted datasets. Existing methods that synthesize full cardiac sequences either rely on explicit ECG signals to parameterize myocardium function, or employ deformable registration without physiological constraints, failing to faithfully reproduce clinically relevant dynamic metrics such as ejection fraction (EF) and ventricular contraction magnitude. We present PhaseFlow, a unified generative framework that overcomes both limitations. PhaseFlow estimates a non-linear cardiac phase signal directly from the input sequence via a segmentation-derived left-ventricular (LV) area curve, capturing the asymmetric dynamics of systole and diastole without any ECG dependency. At inference, this phase signal is provided by a pathology-specific template, informing phase-specific frame generation. A rectified flow model conditioned on the phase and slice position synthesizes the full cardiac motion trajectory in the latent space, decoded into a diffeomorphic displacement field that warps end-diastole pixel intensities directly, eliminating the reconstruction blur often accompanying the variational autoencoder. On the ACDC benchmark, PhaseFlow achieves superior physiological fidelity and image realism, with best LV volume curve $R^2$, structural similarity (SSIM) and generative quality (FID) among all baselines. Ablation studies confirm that each proposed component contributes measurably to the overall performance.

0.15

One Frame, Full Heartbeat: ECG-Free 4D Cardiac Cine MRI Synthesis via Radial-Decomposed Flow Matching

cs.CV ·2026-10-06 ·Shiyi Wang, Ruochen Sun, Xiang Li, Peirong Liu, Fangxu Xing
benchmark similarity 0.66
Abstract

Cine cardiovascular magnetic resonance (CMR) captures the cardiac cycle as a four-dimensional (4D) sequence, but standard acquisition requires electrocardiogram (ECG) gating and repeated breath holds. Visual realism alone does not establish accurate patient-specific ejection fraction (EF) or ventricular volumes. We present PhaseFlow3D, a generative framework that synthesizes a complete 4D cine sequence from a single end-diastolic (ED) three-dimensional (3D) volume without ECG. To capture asymmetric systolic and diastolic dynamics, it represents the cardiac cycle as a piecewise linear phase anchored at ED and end-systolic (ES) time points. At inference, a population-level canonical template supplies this phase without patient-specific temporal information. A phase-conditioned rectified flow model generates a cardiac motion trajectory in latent space. Radial Contraction Decomposition converts each latent state into a 3D displacement field, combining a physics-informed radial component for centripetal myocardial contraction with an image-conditioned residual for rotation and out-of-plane motion. Each frame is generated by directly warping the ED volume, bypassing variational autoencoder decoding. On the combined ACDC and M&Ms benchmark, PhaseFlow3D achieves the lowest EF mean absolute error, the only positive left-ventricular volume-curve $R^2$, and the best distributional quality among compared methods. Ablations confirm each component's contribution. Downstream evaluations demonstrate the utility of the synthesized sequences and displacement fields for segmentation, pathology classification, label propagation, and myocardial strain analysis.

0.23