CS Paper Radar

Learning a Motion Manifold to Constrain Ambiguity in Unsupervised 4D Medical Image Interpolation

Haojin Li, Huazhu Fu, Heng Li, Jiang Liu

cs.CV ·submitted 2026-10-29 14:17 UTC · v1

Abstract

Unsupervised 4D medical image interpolation reconstructs intermediate anatomical states from temporally sparse observations without intermediate supervision. Distinct motion fields may attain comparable endpoint agreement while producing different intermediate anatomy, giving rise to motion ambiguity. This ambiguity is difficult to constrain when many independently adjustable motion variables must be estimated from the observed endpoints. We develop a framework that learns a motion manifold to restrict candidate motion fields while retaining sample-specific variation. Cross-Sample Spectral Basis Learning extracts recurring motion structure from endpoint-derived dense estimates and encodes it in a shared spectral basis. Sample-Conditioned Cayley Basis Reorientation uses predicted motion coordinates to rotate the effective motion directions for each endpoint pair without increasing the number of independent coordinates. Their composition defines a nonlinear family of complete velocity fields across endpoint pairs, accommodating anatomical and motion-state differences within a restricted representation. Integrating each predicted field supports bidirectional reconstruction at arbitrary intermediate times. Theoretical analysis establishes sufficient conditions under which endpoint observations distinguish nearby motions within the learned family. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance among the evaluated methods trained without intermediate volumes and competitive results against methods using intermediate supervision.

Closest papers

Nearest neighbours by meaning across the whole index.

Phase-Aligned Finite-Fourier Periodic Deformation for 4D Medical Image Interpolation

cs.CV ·2026-08-25 ·Haojin Li, Hengzhuo Wang, Zhiheng Ma, Mingyang Ou, Heng Li +1 more
top venue similarity 0.75
Abstract · ACMMM 2026 accepted

4D medical image interpolation aims to recover missing volumes from sparsely observed time points and is important for dynamic anatomical analysis in applications such as cardiac MRI and thoracic CT, where motion is often repetitive or near-periodic over clinically relevant intervals. A key challenge is that this structure is not always encoded directly in deformation representations for interpolation. In addition, physiological motion is often non-uniform, so equal temporal intervals do not necessarily correspond to equal amounts of anatomical change. To address these issues, we formulate interpolation as learning a continuous deformation process with a phase-structured prior. Given two endpoint volumes, we parameterize a phase-conditioned velocity field with a finite Fourier basis, which embeds near-periodic motion patterns directly into the deformation space and supports continuous querying at arbitrary target times. We further introduce a phase-aligned temporal reparameterization that maps normalized within-interval time to a latent motion phase according to deformation variation intensity, thereby better modeling non-uniform motion progression. Intermediate volumes are then synthesized by continuously warping both endpoints, followed by bidirectional fusion and lightweight residual refinement. Experiments on ACDC and 4D-Lung show that the proposed method achieves state-of-the-art performance over existing baselines while producing anatomically plausible and coherent intermediate volumes from sparse observations.

0.66

Low-Rank Velocity Fields as a Structural Prior for Unsupervised 4D Medical Image Interpolation

cs.CV ·2026-08-25 ·Haojin Li, Hengzhuo Wang, Chang Liu, Zhiheng Ma, Heng Li +1 more
top venue similarity 0.74
Abstract · MICCAI 2026

Endpoint-only unsupervised 4D medical image interpolation synthesizes intermediate volumes from sparsely sampled sequences with only the start and end volumes available for training; however, this weakly constrained setting often yields intermediates with unstable boundaries and non-physiological motion, limiting interpretability and downstream analysis. We propose low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts. To capture global coordination and local non-rigid details, we model motion in a coarse-to-fine multi-scale scheme and compose scale-wise deformations at inference to synthesize volumes at arbitrary times. We further provide a theoretical analysis showing that, under Tucker parameterization, low-rank parameters control the smoothness energy of the velocity field, explaining why low-rank modeling promotes smoother motion. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance, remaining competitive with methods trained with intermediate-frame supervision, and producing intermediates with improved structural coherence and more stable anatomical contours.

0.54

Two-Parameter Flow Map Learning for Continuous-Time Diffeomorphic Image Registration

cs.CV ·2026-09-09 ·Mohammadjavad Matinkia, Nilanjan Ray
top venue similarity 0.68
Abstract · Published at European Conference on Computer Vision (ECCV), 2026

Diffeomorphic image registration is central to medical image analysis, enabling anatomically consistent alignment across subjects. Most learning-based diffeomorphic methods model autonomous ODEs(ordinary differential equations) by parameterizing a stationary velocity field and recovering deformations via scaling-and-squaring. While non-autonomous ODEs with time-dependent velocities increase expressiveness, existing approaches rely on numerical integration to implicitly enforce flow structure that entangles model expressiveness with discretization accuracy. We propose a framework to directly learn the continuous-time solution of a non-autonomous ODE formulated as a two-parameterflow map. By enforcing cocycle consistency, a fundamental structural property of time-varying flows, we learn the flow maps without time discretization and velocity integration during training. The framework recovers diffeomorphic mappings at inference using a small number of compositions. Our proposed framework seamlessly incorporates standard registration backbones and improves alignment accuracy consistently across nine datasets while preserving diffeomorphic structure. Notably, the proposed method achieves an average Dice improvement of 2.1% on brain MRI benchmarks, a 12% TRE reduction on lung CT, and a 2.6% Dice gain on cardiac MRI and ultrasound datasets.

0.46

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.65
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.16

Dual-Domain Sparse-View 4D CBCT Reconstruction with Spatial-Temporal Consistency Learning

cs.CV ·2026-10-13 ·Qi Lai, YuTong He
similarity 0.65
Abstract

Four-dimensional cone-beam computed tomography (4D CBCT) provides phase-resolved volumetric images for image-guided radiotherapy. Yet good reconstruction quality usually needs many projections. This increases scan time and radiation dose. We propose STCNet, a sparse-view 4D CBCT reconstruction framework that uses spatial-temporal consistency learning. STCNet reconstructs high-quality images from only 16 projections in each respiratory phase. STCNet integrates physics-driven positional encoding to enforce geometric consistency in the projection domain and introduces temporal encoding in latent space to capture respiratory motion dynamics across phases to capture dynamic respiratory motion across phases. A dual-domain collaborative strategy jointly optimizes both projection and image domains, enhancing structural fidelity and temporal coherence. We tested STCNet on the TCIA-LUNG dataset and a CIRS thorax phantom dataset. STCNet performed better than conventional methods and recent deep learning baselines in image quality, artifact reduction, and structural preservation. On TCIA-LUNG, STCNet reached PSNR values of 33.311, 32.695, and 32.658 dB at phases 2, 5, and 8. The corresponding SSIM values were 0.845, 0.823, and 0.825. On CIRS, STCNet achieved PSNR values up to 36.497 dB and SSIM values up to 0.877. These results support STCNet as a promising framework for low-dose, phase-resolved 4D CBCT reconstruction in image-guided radiotherapy.

0.12

Steer the Sampling, Not the Kernel Grid: Geometry-Guided Sampling Operator for Volumetric Segmentation

cs.CV ·2026-08-26 ·Sizhe Wang, Himashi Peiris, Zhaolin Chen
top venue similarity 0.65
Abstract · Accepted at MICCAI 2026

Accurate 3D segmentation is central to quantitative lesion assessment and anatomy mapping for clinical planning and follow-up. Thin, elongated, and fine anatomical/pathological structures (e.g., vessels) are a particularly challenging case: a one-voxel boundary error can disconnect a branch and change clinically relevant topology. In encoder-decoder networks (e.g., U-Net), repeated downsampling and fixed-grid convolution blur or alias fine structures and weaken orientation cues, so early mistakes propagate across scales. We propose a geometry-guided local operator that steers where features are sampled, rather than deforming convolutional kernels, under a single formulation for both feature refinement (stride 1) and resolution reduction (stride > 1). At each voxel, it predicts a local orientation and bounded step sizes, samples symmetrically along these directions, and transforms paired samples into compact geometric and boundary cues with lightweight mixing; a cross-scale consensus aligns encoder and decoder features at skip connections to reduce geometric mismatch. Replacing all stride 1 and stride 2 operators in a 3D U-Net yields consistent improvements on BraTS, MSD Hepatic Vessel, and TDSC-ABUS, with notably better boundary metrics (e.g., BraTS Dice 86.1 to 88.9, HD95 7.1 to 6.2; TDSC-ABUS HD95 39.1 to 27.8) while reducing parameters from 2.3M to 0.8M. We further demonstrate that the operator can be integrated into other backbones (e.g., nnU-Net, Swin-UNETR, and MedNeXt) without changing their macro-architectures while providing consistent performance gains.

0.24

EchoDiST: Self-distillation-based joint learning for diffusion-conditioned echocardiographic myocardial motion estimation

cs.CV ·2026-10-08 ·Feiyue Qi, Xingyue Wei, Jianwen Luo
similarity 0.64
Abstract · 19 pages, 14 figures

Motion estimation in echocardiography is essential for quantitative assessment of cardiac function and myocardial mechanics, but remains challenging due to image artifacts, limited image information, speckle decorrelation, and the scarcity of ground-truth displacement fields. Anatomy-guided approaches can provide structural information, yet often rely on expert-labeled myocardial segmentations. We propose EchoDiST, a framework for unsupervised echocardiographic myocardial motion estimation that integrates self-distillation-based joint learning with a diffusion-conditioned motion estimation network. Here, unsupervised motion estimation refers to learning without ground-truth displacement fields. The self-distillation strategy jointly optimizes anatomical segmentation and myocardial motion estimation under limited anatomical annotations. Diffusion-based conditioning is used during training with stochastic perturbations, while inference requires only a single deterministic forward pass without iterative reverse-diffusion sampling. EchoDiST was evaluated on three echocardiographic datasets, including two external test datasets under cross-view and cross-dataset settings. Compared with seven representative learning-based methods, EchoDiST consistently improved anatomical alignment, myocardial strain assessment, and motion-derived functional and cardiac-phase assessment. These gains were statistically significant across the evaluated tasks and datasets. Overall, EchoDiST provides an effective approach for reliable myocardial motion estimation under limited anatomical supervision and supports downstream quantitative assessment of cardiac function.

0.21

SynthRCT: Scalable Conditional Deformation Synthesis for Synthetic Repeat CT Generation

cs.CV cs.AIcs.LG ·2026-09-08 ·Tomas Guija-Valiente, Blanca Rodriguez-Gonzalez, Norberto Malpica
publishedcode/data similarity 0.64
Abstract · 11 pages, 4 figures. Accepted at the MIART Workshop, MICCAI 2026. This preprint corresponds to the initial submission prior to peer review

In proton therapy, plans are typically optimized on a single planning CT, making robustness evaluation essential under anatomical changes. However, current scenarios often rely on simplified perturbations that poorly capture complex, patient-specific variability. We propose SynthRCT, a scalable conditional generative framework for 3D anatomical deformation synthesis. Based on a conditional variational autoencoder, SynthRCT learns a latent deformation space and decodes sampled latent codes into local stationary velocity fields conditioned on an input anatomy. Local fields are assembled into coherent full-volume transformations, enabling memory-scalable generation for large field-of-view CT data. We validate the approach on respiratory 4DCT data with multiple breathing-phase anatomies per subject. SynthRCT enables patient-specific sampling of plausible anatomical transformations beyond predefined robustness scenarios. Code available at: https://github.com/TomasGuija/SynthRCT.

0.45