CS Paper Radar

Two-Parameter Flow Map Learning for Continuous-Time Diffeomorphic Image Registration

Mohammadjavad Matinkia, Nilanjan Ray

cs.CV ·submitted 2026-09-09 19:52 UTC · v1
top venue

Abstract

Diffeomorphic image registration is central to medical image analysis, enabling anatomically consistent alignment across subjects. Most learning-based diffeomorphic methods model autonomous ODEs(ordinary differential equations) by parameterizing a stationary velocity field and recovering deformations via scaling-and-squaring. While non-autonomous ODEs with time-dependent velocities increase expressiveness, existing approaches rely on numerical integration to implicitly enforce flow structure that entangles model expressiveness with discretization accuracy. We propose a framework to directly learn the continuous-time solution of a non-autonomous ODE formulated as a two-parameterflow map. By enforcing cocycle consistency, a fundamental structural property of time-varying flows, we learn the flow maps without time discretization and velocity integration during training. The framework recovers diffeomorphic mappings at inference using a small number of compositions. Our proposed framework seamlessly incorporates standard registration backbones and improves alignment accuracy consistently across nine datasets while preserving diffeomorphic structure. Notably, the proposed method achieves an average Dice improvement of 2.1% on brain MRI benchmarks, a 12% TRE reduction on lung CT, and a 2.6% Dice gain on cardiac MRI and ultrasound datasets.

Comment
Published at European Conference on Computer Vision (ECCV), 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Learning a Motion Manifold to Constrain Ambiguity in Unsupervised 4D Medical Image Interpolation

cs.CV ·2026-10-29 ·Haojin Li, Huazhu Fu, Heng Li, Jiang Liu
similarity 0.68
Abstract

Unsupervised 4D medical image interpolation reconstructs intermediate anatomical states from temporally sparse observations without intermediate supervision. Distinct motion fields may attain comparable endpoint agreement while producing different intermediate anatomy, giving rise to motion ambiguity. This ambiguity is difficult to constrain when many independently adjustable motion variables must be estimated from the observed endpoints. We develop a framework that learns a motion manifold to restrict candidate motion fields while retaining sample-specific variation. Cross-Sample Spectral Basis Learning extracts recurring motion structure from endpoint-derived dense estimates and encodes it in a shared spectral basis. Sample-Conditioned Cayley Basis Reorientation uses predicted motion coordinates to rotate the effective motion directions for each endpoint pair without increasing the number of independent coordinates. Their composition defines a nonlinear family of complete velocity fields across endpoint pairs, accommodating anatomical and motion-state differences within a restricted representation. Integrating each predicted field supports bidirectional reconstruction at arbitrary intermediate times. Theoretical analysis establishes sufficient conditions under which endpoint observations distinguish nearby motions within the learned family. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance among the evaluated methods trained without intermediate volumes and competitive results against methods using intermediate supervision.

0.09

Low-Rank Velocity Fields as a Structural Prior for Unsupervised 4D Medical Image Interpolation

cs.CV ·2026-08-25 ·Haojin Li, Hengzhuo Wang, Chang Liu, Zhiheng Ma, Heng Li +1 more
top venue similarity 0.67
Abstract · MICCAI 2026

Endpoint-only unsupervised 4D medical image interpolation synthesizes intermediate volumes from sparsely sampled sequences with only the start and end volumes available for training; however, this weakly constrained setting often yields intermediates with unstable boundaries and non-physiological motion, limiting interpretability and downstream analysis. We propose low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts. To capture global coordination and local non-rigid details, we model motion in a coarse-to-fine multi-scale scheme and compose scale-wise deformations at inference to synthesize volumes at arbitrary times. We further provide a theoretical analysis showing that, under Tucker parameterization, low-rank parameters control the smoothness energy of the velocity field, explaining why low-rank modeling promotes smoother motion. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance, remaining competitive with methods trained with intermediate-frame supervision, and producing intermediates with improved structural coherence and more stable anatomical contours.

0.53

Phase-Aligned Finite-Fourier Periodic Deformation for 4D Medical Image Interpolation

cs.CV ·2026-08-25 ·Haojin Li, Hengzhuo Wang, Zhiheng Ma, Mingyang Ou, Heng Li +1 more
top venue similarity 0.67
Abstract · ACMMM 2026 accepted

4D medical image interpolation aims to recover missing volumes from sparsely observed time points and is important for dynamic anatomical analysis in applications such as cardiac MRI and thoracic CT, where motion is often repetitive or near-periodic over clinically relevant intervals. A key challenge is that this structure is not always encoded directly in deformation representations for interpolation. In addition, physiological motion is often non-uniform, so equal temporal intervals do not necessarily correspond to equal amounts of anatomical change. To address these issues, we formulate interpolation as learning a continuous deformation process with a phase-structured prior. Given two endpoint volumes, we parameterize a phase-conditioned velocity field with a finite Fourier basis, which embeds near-periodic motion patterns directly into the deformation space and supports continuous querying at arbitrary target times. We further introduce a phase-aligned temporal reparameterization that maps normalized within-interval time to a latent motion phase according to deformation variation intensity, thereby better modeling non-uniform motion progression. Intermediate volumes are then synthesized by continuously warping both endpoints, followed by bidirectional fusion and lightweight residual refinement. Experiments on ACDC and 4D-Lung show that the proposed method achieves state-of-the-art performance over existing baselines while producing anatomically plausible and coherent intermediate volumes from sparse observations.

0.66

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.65
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.16

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.65
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.14

LHMCF-Net: A Learned Hyperbolic Mean Curvature Flow Network for Medical Images Segmentation

cs.CV math-ph ·2026-08-21 ·Shuangshuang Duan, Chunlei He, Shoujun Huang, Dexing Kong
similarity 0.64
Abstract

Motivated by the classical Chan-Vese model and the ability of deep priors to capture complex spatial structures, we develop a segmentation model that leverages learned hyperbolic mean curvature flow (LHMCF) as a mathematical foundation for integrating feature space data fidelity and deep structural priors within a unified high-dimensional framework. The proposed LHMCF model is governed by a second-order dissipative hyperbolic PDE, where the introduction of a velocity field provides inertia and momentum to the evolving interface. This hyperbolic mechanism enables the contour to bypass noise-induced local minima and propagate coherently through low-contrast or ambiguous regions, addressing limitations inherent to first-order parabolic flows. To solve the continuous LHMCF model, we construct a deep unfolding network, named LHMCF-Net, which maps the iterative numerical procedure of the PDE into a sequence of discrete evolution stages. Each stage corresponds to one physically interpretable update of the underlying dynamical system, allowing the network to inherit the stability and geometric consistency of the PDE while supporting end-to-end optimization. Comprehensive experiments on three publicly available medical segmentation datasets demonstrate that LHMCF-Net achieves superior performance, particularly in challenging scenarios with low contrast and unclear boundaries. These results highlight the effectiveness of embedding hyperbolic geometric evolution into deep unfolding architectures and underscore the potential of physically inspired models for robust medical image segmentation.

0.28

Factorized Gradients for Scalable Highly-expressive Parametric Diffeomorphisms

cs.CV ·2026-10-26 ·Amit Aflalo, Eran Treister, Chaim Baskin, Oren Freifeld
top venue similarity 0.64
Abstract · Accepted by NeurIPS 2026

Diffeomorphisms provide a flexible, topology-preserving mathematical tool for modeling complex spatial or temporal deformations and are used in various scientific fields. However, making these deformations simultaneously highly expressive and computationally efficient remains challenging. Continuous Piecewise-Affine Based (CPAB) transformations (Freifeld et al., ICCV 2015; IEEE TPAMI 2017) offer an attractive solution by parameterizing a family of diffeomorphisms via continuous velocity fields that are piecewise affine with respect to a chosen tessellation of the domain. Importantly, $d=\dim(θ)$, the dimension of the parameter vector $θ$, depends on the fineness of the tessellation rather than on the data resolution. Despite this compact parameterization, CPAB optimization has long been hindered by the tight coupling between trajectory integration and gradient computation with respect to $θ$. We introduce FG-CPAB, a factorized-gradient formulation for scalable CPAB transformations. By separating integration from parameter-space projection, our method reduces gradient computation complexity from $\mathcal{O}(dTN)$ to $\mathcal{O}(TN+dC)$, where $T$ is the number of integration steps, $N$ is the number of transformed points, and $C$ is the number of tessellation cells. This reformulation yields speedups of up to four orders of magnitude (e.g., $\approx 10^4\times$ in 2D), substantial memory savings (e.g., $\approx 500\times$ reduction in peak GPU memory usage in 2D), and dramatically higher expressiveness. This makes fine-tessellation CPAB practical in 2D and 3D for the first time, enabling highly expressive parametric diffeomorphisms.

0.48

Synthetic Dataset Generation, Physical Consistency and Active Learning for Shape-Informed Surrogate Modeling of Hemodynamics

cs.CE physics.flu-dyn ·2026-10-19 ·Francesco Romor, Richard Schussnig, Charles A. Taylor, Gerhard A. Holzapfel, Alfonso Caiazzo
similarity 0.64
Abstract

Model order reduction has the potential to enable real-time patient-specific assessment of cardiovascular flows. However, it still faces significant challenges stemming from the geometric variability of vascular anatomies. Building upon the SynthAorta dataset (Bosnjak et al., IEEE Trans. Med. Imag. 45(1), 2026) of physiological aortic geometries, we generate an extensive dataset of physiologically consistent computational fluid dynamics solutions through an automatic boundary-condition adjustment procedure. A common reference geometry allows all patient-specific anatomies to be represented by displacement fields, providing point-to-point correspondence without the need for geometric registration. Based on this dataset, we develop Graph U-Net and Transformer U-Net surrogate models to predict velocity and pressure fields at peak systole. We further investigate two strategies to enhance data efficiency and prediction accuracy: active learning and differentiable physical consistency constraints based on the finite element residual. The results show that active learning is strongly regime-dependent: while it offers little benefit over random sampling during early training, it improves performance during fine-tuning through gradient- and subspace-based acquisition strategies. Similarly, physical consistency constraints prove to be substantially more effective as a fine-tuning objective than as a regularizer applied throughout training. Finally, out-of-distribution studies demonstrate that the primary limitation of surrogate models lies in the geometric support of the underlying parametrization rather than in the neural network architectures themselves. The proposed framework combines synthetic dataset generation, geometry-aware surrogate modeling, physics-informed optimization, and active learning into a scalable workflow for inter-patient hemodynamic prediction.

0.03