CS Paper Radar

Synthetic Dataset Generation, Physical Consistency and Active Learning for Shape-Informed Surrogate Modeling of Hemodynamics

Francesco Romor, Richard Schussnig, Charles A. Taylor, Gerhard A. Holzapfel, Alfonso Caiazzo

cs.CE physics.flu-dyn ·submitted 2026-10-19 18:28 UTC · v1

Abstract

Model order reduction has the potential to enable real-time patient-specific assessment of cardiovascular flows. However, it still faces significant challenges stemming from the geometric variability of vascular anatomies. Building upon the SynthAorta dataset (Bosnjak et al., IEEE Trans. Med. Imag. 45(1), 2026) of physiological aortic geometries, we generate an extensive dataset of physiologically consistent computational fluid dynamics solutions through an automatic boundary-condition adjustment procedure. A common reference geometry allows all patient-specific anatomies to be represented by displacement fields, providing point-to-point correspondence without the need for geometric registration. Based on this dataset, we develop Graph U-Net and Transformer U-Net surrogate models to predict velocity and pressure fields at peak systole. We further investigate two strategies to enhance data efficiency and prediction accuracy: active learning and differentiable physical consistency constraints based on the finite element residual. The results show that active learning is strongly regime-dependent: while it offers little benefit over random sampling during early training, it improves performance during fine-tuning through gradient- and subspace-based acquisition strategies. Similarly, physical consistency constraints prove to be substantially more effective as a fine-tuning objective than as a regularizer applied throughout training. Finally, out-of-distribution studies demonstrate that the primary limitation of surrogate models lies in the geometric support of the underlying parametrization rather than in the neural network architectures themselves. The proposed framework combines synthetic dataset generation, geometry-aware surrogate modeling, physics-informed optimization, and active learning into a scalable workflow for inter-patient hemodynamic prediction.

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.75
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

Physics Informed Neural Network model for the dynamical study of Abdominal Aortic Aneurysm

cs.AI physics.flu-dyn ·2026-09-14 ·Adrián Robles Arques, Martín Ruiz Fernandez, Javier Sanchis, Miguel A. Teruel, Juan Trujillo
similarity 0.69
Abstract · 38 pages, 9 figures and 2 tables

We present the development and application of a three-dimensional Physics-Informed Neural Network (PINN) framework for the investigation of haemodynamic behaviour in the human aorta. The model incorporates a time-resolved simulation of pulsatile blood flow over a two-minute interval, enabling the extraction of pressure and velocity fields with high temporal fidelity. The mechanical stress exerted on the aortic wall was quantified through Laplace's law, with temporal averaging applied to derive representative stress distributions. This approach circumvents the computational overhead associated with conventional computational fluid dynamics (CFD) methods by eliminating mesh generation and exploiting the automatic differentiation capabilities inherent to neural networks. The proposed methodology demonstrates that PINNs can serve as an efficient and accurate alternative for modelling complex vascular flow phenomena, offering significant advantages in scalability and computational cost reduction while maintaining physical consistency.

0.20

Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation

cs.LG physics.med-phphysics.flu-dyn ·2026-08-31 ·Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
similarity 0.67
Abstract

Quantifying mitral regurgitation severity remains limited by the assumptions of clinical flow convergence methods, while high-fidelity simulation and volumetric velocimetry are too slow for routine use. We investigate whether a learned solution operator can reconstruct transient three-dimensional transvalvular hemodynamics from the sparse observation an in-vitro experiment actually provides: a single planar velocity slice and two boundary pressure traces. A Deep Operator Network is pretrained on an experimentally benchmarked URANS database spanning eleven mitral regurgitation orifice phantoms, learning a mapping from a masked two-component planar velocity snapshot to the surrounding volumetric field, and is subsequently adapted to unseen target cases by fine-tuning on their sparse measurements. Adaptation reliably corrects the flow topology within the supervised plane, reorienting a strongly eccentric jet that the pretrained operator predicts as straight, and yields full-field predictions in minutes rather than the days required by the underlying simulations. Its influence decays sharply with distance from that plane, however: measured against phase-resolved particle image velocimetry, the reconstruction error rises from 24.6% at 2mm to 52.6% at 6mm, and the resulting mismatch between corrected and uncorrected layers degrades physical consistency. Single-plane supervision thus constrains the observed plane far more effectively than the surrounding volume, which we identify as the principal obstacle to coherent 4D reconstruction from sparse planar data.

0.18

Low-Rank Velocity Fields as a Structural Prior for Unsupervised 4D Medical Image Interpolation

cs.CV ·2026-08-25 ·Haojin Li, Hengzhuo Wang, Chang Liu, Zhiheng Ma, Heng Li +1 more
top venue similarity 0.66
Abstract · MICCAI 2026

Endpoint-only unsupervised 4D medical image interpolation synthesizes intermediate volumes from sparsely sampled sequences with only the start and end volumes available for training; however, this weakly constrained setting often yields intermediates with unstable boundaries and non-physiological motion, limiting interpretability and downstream analysis. We propose low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts. To capture global coordination and local non-rigid details, we model motion in a coarse-to-fine multi-scale scheme and compose scale-wise deformations at inference to synthesize volumes at arbitrary times. We further provide a theoretical analysis showing that, under Tucker parameterization, low-rank parameters control the smoothness energy of the velocity field, explaining why low-rank modeling promotes smoother motion. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance, remaining competitive with methods trained with intermediate-frame supervision, and producing intermediates with improved structural coherence and more stable anatomical contours.

0.54

Learning Unsteady Aneurysm Hemodynamics with Physics-Informed DeepONets

cs.LG stat.MLphysics.flu-dyn ·2026-08-13 ·Oscar L. Cruz-Gonzalez, Valérie Deplano, Badih Ghattas
similarity 0.64
Abstract

Clinically actionable, patient-specific hemodynamic assessment, specifically wall shear stress, vortex structure and pressure distributions, is critical for determining risky or unfavorable evolution in Abdominal Aortic Aneurysms (AAA). While Physics-Informed Deep Operator Networks (PI-DeepONets) show promising results in complementing established 5 tools such as Computational Fluid Dynamics (CFD), a persistent architectural challenge remains for complex 3D flows. In this direction, we propose a Modified Multi-Input Multi-Output PI-DeepONets (M3PI-DeepONet) designed for predicting unsteady flows in an idealized AAA geometry. Central to our model is the Aggregated Injection strategy, where latent representations from multiple input branches are fused prior to trunk injection, allowing the coordinate basis to adapt to multiple physical constraints. To the best of our knowledge, this is the first architecture to combine the layer-wise gating mechanism with a multi-branch operator-network topology, yielding an input-adaptive trunk basis. Additionally, we integrate the 3D Navier-Stokes equations as governing physical laws, so the model is trained based on physics-informed residuals, initial and boundary conditions, and only 0.3% of the labeled internal data together with the selected branch-conditioning signals. The M3PI-DeepONet simultaneously predicts unsteady 3D flow velocity and pressure fields with an average relative L2 velocity error below 4% and pressure error around 5% while achieving a conservative retained-cycle inference speedup of approximately 36x compared to reference CFD simulations once the branch inputs used for conditioning are available. This work advances the application of deep learning in cardiovascular disease modeling, marking step toward real-time, non-invasive clinical diagnostics.

0.04

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

cs.CV ·2026-10-07 ·Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
code/data similarity 0.64
Abstract · 22 pages, 5 figures, 10 tables, including references and appendix. Code and pretrained models: https://github.com/G2304138H/PPCAR-Net . Proj…

Sparse-view 3D coronary reconstruction commonly relies on cross-view correspondence and triangulation, which are vulnerable to vessel overlap and foreshortening, or on volumetric prediction followed by vascular-graph extraction, which does not directly provide centrelines and radii. We introduce PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that directly predicts a branch-structured centreline-and-radius representation without explicit point matching, triangulation, or an intermediate volume. Given a variable number of segmented views, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch presence, B-spline centreline trajectories, and dense radius profiles. Projection-guided geometry and radius refiners then sample local evidence from the input views and apply residual corrections learned with 3D supervision. We evaluate representation fidelity and sparse-view reconstruction quantitatively and qualitatively. On simulated angiographic masks generated from CT-derived coronary anatomy, PPCAR-Net produces better connected artery reconstructions and achieves strong centreline accuracy, particularly for RCA, while maintaining competitive volumetric overlap. Coarse-to-fine inference takes 121 ms, enabling real-time reconstruction.

0.29

Anatomy-Informed Neural Networks: Encoding Anatomic Priors in Loss and Architecture, with an SE(3) Formulation of Guidewire-Induced Aortoiliac Deformation

cs.AI cs.CVcs.RO ·2026-08-21 ·David P. Stonko
similarity 0.64
Abstract · 42 pages, 10 figures, 4 tables

Deep-learning models of anatomy can be numerically plausible yet anatomically impossible, and they generalize poorly when data are scarce. We introduce Anatomy-Informed Neural Networks (AINN), in which soft anatomic priors enter as penalty terms in the loss (e.g., a branching penalty that treats a renal transplant artery off the iliac instead of the aorta as unexpected rather than impossible), in direct analogy to a physics-informed neural network, and hard anatomic priors (e.g., continuity of the vessel) are built into the architecture and state representation, making such invalid predictions impossible by construction wherever the prior admits architectural enforcement. We develop it on a clinical test case with limited data: how the aortoiliac tree deforms when a stiff wire is introduced endoluminally. This is important to contemporary aortic surgery and will matter to autonomous endovascular navigation. We lift the vessel centerline and the wire path from R^3 to curves of frames in the Lie group SE(3), and couple a Cosserat-rod wire to a tortuosity-modulated, anatomically anchored vessel through a unilateral lumen-contact inequality. The prediction is a constrained minimizer of the coupled elastic energy, with contact forces as its Lagrange multipliers. Supervision is a Wasserstein-2 optimal-transport loss between the predicted projection through the C-arm geometry and the observed angiogram, so a 2D angiogram can train a 3D prediction. The kinematics, loss and projection are verified against known ground truth; the mechanics solver only against its own optimality conditions, and predicted displacement is not yet mesh-converged. Here, no network is trained. Future work will transfer this in silico model to real CT scans and test whether it improves predictive accuracy and reduces the training data required.

0.31

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

cs.CV cs.LGq-bio.QM ·2026-08-20 ·Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais
published similarity 0.64
Abstract · International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

0.23