CS Paper Radar

Anatomy-Informed Neural Networks: Encoding Anatomic Priors in Loss and Architecture, with an SE(3) Formulation of Guidewire-Induced Aortoiliac Deformation

David P. Stonko

cs.AI cs.CVcs.RO ·submitted 2026-08-21 17:38 UTC · v1

Abstract

Deep-learning models of anatomy can be numerically plausible yet anatomically impossible, and they generalize poorly when data are scarce. We introduce Anatomy-Informed Neural Networks (AINN), in which soft anatomic priors enter as penalty terms in the loss (e.g., a branching penalty that treats a renal transplant artery off the iliac instead of the aorta as unexpected rather than impossible), in direct analogy to a physics-informed neural network, and hard anatomic priors (e.g., continuity of the vessel) are built into the architecture and state representation, making such invalid predictions impossible by construction wherever the prior admits architectural enforcement. We develop it on a clinical test case with limited data: how the aortoiliac tree deforms when a stiff wire is introduced endoluminally. This is important to contemporary aortic surgery and will matter to autonomous endovascular navigation. We lift the vessel centerline and the wire path from R^3 to curves of frames in the Lie group SE(3), and couple a Cosserat-rod wire to a tortuosity-modulated, anatomically anchored vessel through a unilateral lumen-contact inequality. The prediction is a constrained minimizer of the coupled elastic energy, with contact forces as its Lagrange multipliers. Supervision is a Wasserstein-2 optimal-transport loss between the predicted projection through the C-arm geometry and the observed angiogram, so a 2D angiogram can train a 3D prediction. The kinematics, loss and projection are verified against known ground truth; the mechanics solver only against its own optimality conditions, and predicted displacement is not yet mesh-converged. Here, no network is trained. Future work will transfer this in silico model to real CT scans and test whether it improves predictive accuracy and reduces the training data required.

Comment
42 pages, 10 figures, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Synthetic Dataset Generation, Physical Consistency and Active Learning for Shape-Informed Surrogate Modeling of Hemodynamics

cs.CE physics.flu-dyn ·2026-10-19 ·Francesco Romor, Richard Schussnig, Charles A. Taylor, Gerhard A. Holzapfel, Alfonso Caiazzo
similarity 0.64
Abstract

Model order reduction has the potential to enable real-time patient-specific assessment of cardiovascular flows. However, it still faces significant challenges stemming from the geometric variability of vascular anatomies. Building upon the SynthAorta dataset (Bosnjak et al., IEEE Trans. Med. Imag. 45(1), 2026) of physiological aortic geometries, we generate an extensive dataset of physiologically consistent computational fluid dynamics solutions through an automatic boundary-condition adjustment procedure. A common reference geometry allows all patient-specific anatomies to be represented by displacement fields, providing point-to-point correspondence without the need for geometric registration. Based on this dataset, we develop Graph U-Net and Transformer U-Net surrogate models to predict velocity and pressure fields at peak systole. We further investigate two strategies to enhance data efficiency and prediction accuracy: active learning and differentiable physical consistency constraints based on the finite element residual. The results show that active learning is strongly regime-dependent: while it offers little benefit over random sampling during early training, it improves performance during fine-tuning through gradient- and subspace-based acquisition strategies. Similarly, physical consistency constraints prove to be substantially more effective as a fine-tuning objective than as a regularizer applied throughout training. Finally, out-of-distribution studies demonstrate that the primary limitation of surrogate models lies in the geometric support of the underlying parametrization rather than in the neural network architectures themselves. The proposed framework combines synthetic dataset generation, geometry-aware surrogate modeling, physics-informed optimization, and active learning into a scalable workflow for inter-patient hemodynamic prediction.

0.03

Physics Informed Neural Network model for the dynamical study of Abdominal Aortic Aneurysm

cs.AI physics.flu-dyn ·2026-09-14 ·Adrián Robles Arques, Martín Ruiz Fernandez, Javier Sanchis, Miguel A. Teruel, Juan Trujillo
similarity 0.62
Abstract · 38 pages, 9 figures and 2 tables

We present the development and application of a three-dimensional Physics-Informed Neural Network (PINN) framework for the investigation of haemodynamic behaviour in the human aorta. The model incorporates a time-resolved simulation of pulsatile blood flow over a two-minute interval, enabling the extraction of pressure and velocity fields with high temporal fidelity. The mechanical stress exerted on the aortic wall was quantified through Laplace's law, with temporal averaging applied to derive representative stress distributions. This approach circumvents the computational overhead associated with conventional computational fluid dynamics (CFD) methods by eliminating mesh generation and exploiting the automatic differentiation capabilities inherent to neural networks. The proposed methodology demonstrates that PINNs can serve as an efficient and accurate alternative for modelling complex vascular flow phenomena, offering significant advantages in scalability and computational cost reduction while maintaining physical consistency.

0.20

Learning Unsteady Aneurysm Hemodynamics with Physics-Informed DeepONets

cs.LG stat.MLphysics.flu-dyn ·2026-08-13 ·Oscar L. Cruz-Gonzalez, Valérie Deplano, Badih Ghattas
similarity 0.62
Abstract

Clinically actionable, patient-specific hemodynamic assessment, specifically wall shear stress, vortex structure and pressure distributions, is critical for determining risky or unfavorable evolution in Abdominal Aortic Aneurysms (AAA). While Physics-Informed Deep Operator Networks (PI-DeepONets) show promising results in complementing established 5 tools such as Computational Fluid Dynamics (CFD), a persistent architectural challenge remains for complex 3D flows. In this direction, we propose a Modified Multi-Input Multi-Output PI-DeepONets (M3PI-DeepONet) designed for predicting unsteady flows in an idealized AAA geometry. Central to our model is the Aggregated Injection strategy, where latent representations from multiple input branches are fused prior to trunk injection, allowing the coordinate basis to adapt to multiple physical constraints. To the best of our knowledge, this is the first architecture to combine the layer-wise gating mechanism with a multi-branch operator-network topology, yielding an input-adaptive trunk basis. Additionally, we integrate the 3D Navier-Stokes equations as governing physical laws, so the model is trained based on physics-informed residuals, initial and boundary conditions, and only 0.3% of the labeled internal data together with the selected branch-conditioning signals. The M3PI-DeepONet simultaneously predicts unsteady 3D flow velocity and pressure fields with an average relative L2 velocity error below 4% and pressure error around 5% while achieving a conservative retained-cycle inference speedup of approximately 36x compared to reference CFD simulations once the branch inputs used for conditioning are available. This work advances the application of deep learning in cardiovascular disease modeling, marking step toward real-time, non-invasive clinical diagnostics.

0.04

An Anatomy-Aware Staged Pipeline for Vessel-Specific Intracranial Aneurysm Segmentation in CT and MR Angiography

eess.IV cs.CV ·2026-10-15 ·Gniewosz Drwiega, Wojciech Szymanski, Marek Wodzinski
published similarity 0.60
Abstract · Submitted version (7 August 2026) of a paper accepted at SWITCH+ 2026, a MICCAI 2026 workshop (TopAneu 2026 challenge track). Table 1 entrie…

The TopAneu 2026 challenge requires intracranial aneurysms to be segmented at the voxel level and assigned to one of more than fifty vessel-specific classes, on CT and MR angiography alike. We address it with a six-stage anatomy-aware pipeline rather than a single segmentation network. A logistic-regression classifier routes each scan to a modality-specific branch; networks segment the vasculature, first as a binary mask and then over the full 36-class arterial taxonomy; a candidate localiser turns raw angiography and vessel priors into suspicious regions; a candidate-centred network segments the lesion in each crop; connected components become instances; and a per-instance classifier assigns each its anatomical location. Two principles organise the design. Whenever an upstream model output becomes a downstream training input it is generated out-of-fold, so no stage trains on unrealistically clean predictions of itself. And the anatomical decision is made once per lesion rather than once per voxel, which fits the data: of 406 connected aneurysm components in the full release, 405 carry exactly one location label. Task 1 is read off the Task 2 mask, making the two consistent by construction. We report stage-wise performance and a five-part ablation isolating what vessel priors and class-aware sampling contribute at each stage.

0.24

Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation

cs.LG physics.med-phphysics.flu-dyn ·2026-08-31 ·Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
similarity 0.60
Abstract

Quantifying mitral regurgitation severity remains limited by the assumptions of clinical flow convergence methods, while high-fidelity simulation and volumetric velocimetry are too slow for routine use. We investigate whether a learned solution operator can reconstruct transient three-dimensional transvalvular hemodynamics from the sparse observation an in-vitro experiment actually provides: a single planar velocity slice and two boundary pressure traces. A Deep Operator Network is pretrained on an experimentally benchmarked URANS database spanning eleven mitral regurgitation orifice phantoms, learning a mapping from a masked two-component planar velocity snapshot to the surrounding volumetric field, and is subsequently adapted to unseen target cases by fine-tuning on their sparse measurements. Adaptation reliably corrects the flow topology within the supervised plane, reorienting a strongly eccentric jet that the pretrained operator predicts as straight, and yields full-field predictions in minutes rather than the days required by the underlying simulations. Its influence decays sharply with distance from that plane, however: measured against phase-resolved particle image velocimetry, the reconstruction error rises from 24.6% at 2mm to 52.6% at 6mm, and the resulting mismatch between corrected and uncorrected layers degrades physical consistency. Single-plane supervision thus constrains the observed plane far more effectively than the surrounding volume, which we identify as the principal obstacle to coherent 4D reconstruction from sparse planar data.

0.18

Agentic AI Reasoning and Learned Sampling for Task-Aware Projection Selection in Sparse-View CT: Predicting Hemodynamics

cs.AI physics.flu-dyn ·2026-10-28 ·Mahmoud Elhadidy, Roshan M. D'Souza, Amirhossein Arzani
similarity 0.59
Abstract

Sparse-view computed tomography (CT) reduces the number of acquired projections, but conventional sampling strategies are designed primarily for image reconstruction rather than for downstream physical inference. Here, we investigate optimal task-aware projection selection for directly predicting hemodynamics from sparse CT angiography (CTA) measurements. Using computational fluid dynamics simulations of intracranial aneurysms, we generate synthetic fan-beam CTA projections and train a Fourier neural operator (FNO) to predict two targets: the spatially resolved time-averaged wall shear stress (TAWSS) field and the spatially averaged TAWSS. The FNO was coupled with optimal input selection for simultaneous optimal sampling and training. Our goal was to investigate if agentic AI could discover optimal sampling strategies that outperform current methods. We compared fixed uniform and golden-angle sampling with three task-aware optimal selection strategies: Gumbel-Softmax, a Soft top-K method, and an agentic AI selector. The methods were compared at different view selection budgets. A detailed analysis of the AI agent was performed to understand its reasoning and performance. For spatially resolved TAWSS, Agentic and Soft top-K achieve the lowest mean errors (Agentic performs slightly better) and substantially outperform fixed sampling under extreme sparsity. For spatially averaged TAWSS, optimized selection becomes important at extremely sparse acquisitions. Analysis of the selected masks reveals multiple distinct subsets concentrated around informative regions. Moreover, masks optimized for hemodynamic prediction yield poor image reconstructions, showing that task-optimal acquisition differs fundamentally from reconstruction-optimal acquisition. This work suggests the possibility of designing sparse acquisitions directly around downstream physical quantities.

0.27

Do Medical Vision Models Reason About Anatomy? Probing the Spatial Inductive Biases of Learned Visual Representations

eess.IV cs.AIcs.CVcs.LG ·2026-08-28 ·Naren Akash, Neeraja Ramanan
similarity 0.58
Abstract

Interpreting a CT scan means comparing structures on either side, judging how far apart organs sit, and knowing where each one belongs. Medical vision encoders are evaluated on diagnostic accuracy, or through assembled multimodal systems where a failure is hard to attribute, so it remains unclear whether their representations support any of this. We construct SPAR-Bench, eight probes over multi-organ abdominal CT that separate coordinate localization, relational reasoning, and spatial queries, and apply them to five architectural configurations and three medical foundation models, frozen and finetuned. Probes that ask for a comparison within the slice stay at chance, and neither pretraining scale, finetuning, nor architecture closes the gap. Probes that appear solved in domain fall to chance under zero-shot transfer, indicating that their accuracy reflects recall of canonical anatomy rather than computation over the image. Reading the same frozen features with a pooled head rather than the full set of tokens moves relational recovery from 0.7% to 67.8%, so pooled probing understates what a representation holds. Questions the encoders answer well are answered at chance by four open-weight MLLMs. Our results suggest these encoders carry a map of where organs usually lie, and little of the machinery for comparing structures within a particular patient. Code and data will be available at https://spar-bench.github.io.

0.13

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.58
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11