CS Paper Radar

Do Medical Vision Models Reason About Anatomy? Probing the Spatial Inductive Biases of Learned Visual Representations

Naren Akash, Neeraja Ramanan

eess.IV cs.AIcs.CVcs.LG ·submitted 2026-08-28 08:59 UTC · v1

Abstract

Interpreting a CT scan means comparing structures on either side, judging how far apart organs sit, and knowing where each one belongs. Medical vision encoders are evaluated on diagnostic accuracy, or through assembled multimodal systems where a failure is hard to attribute, so it remains unclear whether their representations support any of this. We construct SPAR-Bench, eight probes over multi-organ abdominal CT that separate coordinate localization, relational reasoning, and spatial queries, and apply them to five architectural configurations and three medical foundation models, frozen and finetuned. Probes that ask for a comparison within the slice stay at chance, and neither pretraining scale, finetuning, nor architecture closes the gap. Probes that appear solved in domain fall to chance under zero-shot transfer, indicating that their accuracy reflects recall of canonical anatomy rather than computation over the image. Reading the same frozen features with a pooled head rather than the full set of tokens moves relational recovery from 0.7% to 67.8%, so pooled probing understates what a representation holds. Questions the encoders answer well are answered at chance by four open-weight MLLMs. Our results suggest these encoders carry a map of where organs usually lie, and little of the machinery for comparing structures within a particular patient. Code and data will be available at https://spar-bench.github.io.

Closest papers

Nearest neighbours by meaning across the whole index.

A Modular Agent for Reliable and Auditable Spatial Relation Verification in CT Scans

cs.CV cs.AI ·2026-08-21 ·Simon Vincent Abel, Heiko Hillenhagen, Michael Götz, Timo Ropinski, Ayhan Can Erdur +1 more
publishedbenchmark similarity 0.74
Abstract

Reliable spatial understanding is an important prerequisite for future medical vision-language systems that aim to support radiological report generation and structured image understanding. While modern vision-language models (VLMs) show promising performance on many medical imaging tasks, recent evidence suggests they remain weak in controlled spatial reasoning and often fail to reliably ground spatial relations in image evidence. Given that radiological reasoning hinges on understanding the relative positions of anatomical structures and findings, this spatial weakness poses risks to diagnostic accuracy. We present a modular medical imaging agent for binary spatial relation verification in axial CT slices. Instead of directly predicting spatial answers end-to-end, the system decomposes the task into explicit stages: language parsing, anatomical localization, and deterministic geometric verification. Natural-language queries are converted into structured relation tuples, queried organs are localized with a YOLO-based detector, and the final spatial decision is computed from object centers using deterministic geometric rules. We evaluate the approach on the held-out MIRP spatial QA benchmark and compare it against representative end-to-end VLM baselines. The best-performing hybrid configuration reaches 94.1% accuracy and 94.2% F1, outperforming direct Qwen2-VL prompting by 42.5 percentage points in accuracy, while preserving interpretable intermediate representations and auditable reasoning stages. The results suggest that explicit modular spatial verification can serve as a promising building block for future report-oriented medical imaging agents.

0.31

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

cs.CV cs.AI ·2026-11-07 ·Szymon Płotka, Gizem Mert, Pedro R. A. S. Bassi, Wenxuan Li, Zongwei Zhou +7 more
publishedcode/data similarity 0.72
Abstract · NeurIPS 2026

Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop. We propose Anatomy-Activated Mixture-of-Experts (A$^{2}$MoE), a framework that incorporates anatomical inductive biases within the model's computational path. A$^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical composition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}$MoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A$^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning. The code is available at https://github.com/gmum/A2MoE.

0.41

REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models

cs.CV ·2026-11-06 ·Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi
top venue similarity 0.69
Abstract · 32 pages, 6 figures, Accepted to NeurIPS 2026 ED Track

Evaluation of 3D medical foundation models is typically dominated by downstream task scores, which entangle representation quality with adaptation choices. This is especially critical in volumetric imaging, where spacing and anisotropy can substantially alter image statistics while the anatomy itself remains unchanged. We therefore introduce \textbf{REFORM-3D}, a \textbf{R}epresentation-centric \textbf{E}valuation \textbf{F}ramew\textbf{OR}k for benchmarking frozen 3D medical vision foundation \textbf{M}odels across three questions: Acquisition Robustness, asking whether features remain stable when spacing varies while anatomy is fixed; Cross-Modal Anatomical Alignment, asking whether labeled anatomical structures remain recoverable across modalities under balanced bidirectional retrieval; and Anatomical Transfer, asking whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. These are also pretraining questions, because what a 3D encoder learns depends on how volumes are geometrically presented during self-supervised pretraining. We further introduce Med3DINO encoder family, pretrained on $62.6$K unlabeled MR, CT, PET, CTA, and CBCT volumes under three explicit geometric assumptions: isotropic normalization, voxel-relative sampling, and spacing-aware resampling. Across Med3DINO and heterogeneous external encoders, REFORM-3D reveals module-specific strengths rather than a single model ordering. Within the controlled Med3DINO comparison, voxel-relative sampling yields lower embedding drift, whereas spacing-aware resampling favors anatomical transfer; semantic-transfer advantages depend on the dataset and feature type. Project link: \href{https://endarzboy.github.io/reform3d-website/}{\highlightLR{REFORM-3D}}.

0.50

A 3D foundation model unifying CT interpretation and segmentation

cs.CV ·2026-11-04 ·Yulu Xie, Zilong Li, Shen Xu, Yifan Bai, Liuhong Shi +12 more
similarity 0.67
Abstract · 114 pages, including Supplementary Information; 7 main figures and 2 Extended Data figures

Radiologists interpret computed tomography (CT) scans by jointly determining what a finding represents and where it lies in three-dimensional (3D) anatomy. However, CT models have treated CT interpretation and 3D segmentation as separate tasks, leaving textual findings spatially unverifiable and overlooking potential synergy between clinical understanding and spatial perception. Here we present HoloCT, a generalist 3D foundation model unifying CT interpretation and voxel-level segmentation by jointly modelling whole-volume context and fine-grained anatomical detail, providing 3D masks as evidence. We curated HoloDATA, comprising 195,921 CT scans from 73 public datasets and six clinical cohorts, with 6.2 million instruction dialogues and 2.8 million CT-mask pairs. Across 346 tasks spanning segmentation, lesion screening, visual question answering, and report generation on 61 internal and 12 external datasets, HoloCT outperformed specialist and foundation models. In multicentre validation across 11,455 clinical CT scans from five hospitals, HoloCT outperformed competing models in lesion segmentation and report generation by 18.2 and 15.3 points. It also achieved 85.1% mean accuracy in screening thyroid tumours and colon lesions, exceeding all four participating radiologists in a retrospective reader study. Further analyses revealed bidirectional semantic-spatial synergy: language-guided segmentation delineated unseen anatomical structures and lesions as well as diffuse free-text findings, outperforming the leading approach by 22.1 points, whereas prompting the model to generate corresponding 3D masks alongside its textual outputs significantly improved interpretation performance. HoloCT shows that clinical understanding and spatial perception can be learned together within a single foundation model and offers a path towards more accurate and reliable CT analysis.

0.25

The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging

eess.IV cs.CVcs.LG ·2026-10-09 ·Fabian Drexel, Bernhard Kainz, Jakob N. Kather, Daniel Rueckert, Lisa C. Adams +2 more
similarity 0.66
Abstract · 45 pages, 6 figures

Joint-embedding predictive architectures (JEPAs) learn by predicting teacher representations of masked regions from visible context. Point prediction summarizes the conditional target distribution and cannot reproduce variation that the context does not resolve. We call this constraint predictability bias. In computed tomography (CT), recurrent anatomy is predictable from context, whereas the sporadic, localized pathology that determines clinical interpretation often is not. We introduce TAP-JEPA, a ViT-B/3D trained on 113,611 CT volumes that is competitive with state-of-the-art encoders (COLIPRI, Merlin, VoxelFM) in scan-level classification. We then audit the learned predictive pathway by replaying the exact masking, teacher, and predictor computations used during training. Prediction lowers the mean Skill (prevalence-normalized average precision) from 0.388 to 0.271 for pathology, but only from 0.921 to 0.873 for anatomy. Along the teacher direction, separating pathology from matched control regions in the same organ, prediction moves pathology 34.7% toward the controls and controls 13.6% toward pathology, with larger shifts farther from visible context. Replacing visible matched-control representations increases surrounding-target prediction loss more than fully replacing pathology representations across four pathology categories. Downstream, removing all final-layer pathology tokens reduces the decision margin by at most 0.45% in four of seven scan-level probes. Together, these results show that contextual predictability is not a sufficient proxy for clinical relevance in medical representation learning. Training objectives should therefore retain diagnostic features regardless of their predictability from surrounding anatomy.

0.19

Learning Where to Look: Anatomical Grounding and Guided Attention for Cardiac MRI Vision-Language Models

cs.CV ·2026-09-30 ·Bangwei Guo, Xiao Chen, Boris Mailhe, Jia Yao, Yiqing Wang +6 more
similarity 0.65
Abstract

Cardiac magnetic resonance imaging (CMR) enables assessment of cardiac anatomy, ventricular function, and myocardial tissue characteristics. Clinicians interpret these images by identifying cardiac structures and focusing on the regions relevant to each clinical question, motivating anatomically guided vision-language models (VLMs). Yet CMR-specific supervision for anatomical localisation and clinical question answering remains limited. To address this gap, we investigate fine-grained CMR visual question answering through anatomical grounding and guided attention. We construct 128,915 anatomical-grounding and 42,799 clinical QA pairs across short-axis cine, late gadolinium enhancement, and long-axis cine. These datasets support anatomical recognition, localisation, and clinical assessment without requiring paired reports for individual training images. To help the model learn where to look, we introduce Cardiac Anatomy-Routed Attention (CARA), which selects predicted anatomical priors according to the question and guides decoder attention with learned task-specific strengths. Combining anatomical grounding pretraining with CARA yields our model, CARA-VL. Experiments demonstrate CARA-VL's strengths in clinical assessment and regional localisation across CMR imaging settings, with promising generalization to an external clinical cohort. Together, our data and method provide a practical framework for studying and advancing cardiac visual understanding in VLMs. We will release the QA data derived from public datasets upon publication.

0.37

Localization Lens for Improving Medical Vision-Language Models

cs.CV cs.AI ·2026-10-03 ·Hasan Farooq, Murtaza Taj, Mehwish Nasim, Arif Mahmood
top venuecode/datahighly cited similarity 0.65
Abstract · 10 pages, 1 figure, Medical Image Computing and Computer Assisted Intervention (MICCAI)

Medical Vision-Language Models (Med-VLMs) have demonstrated strong capabilities in clinical tasks. However, they often struggle to understand anatomical structures and spatial positioning, which are crucial for medical reasoning. To address this, we propose a localization-aware enhancement to the Med-VLM pipeline, introducing improvements at three levels: data,architecture, and alignment. First, we introduce localization lens, a set of expert-validated representations that provide richer anatomical and positional context. However, as these representations increase input complexity, we integrate pixel shuffle within the model architecture to filter and refine representations, enhancing spatial information processing while preserving anatomical continuity. Lastly, to effectively align the localization lens representations with textual features, we incorporate decoupled contrastive loss (DCL) alongside the standard loss function. This ensures better feature discrimination and robustness, particularly in data limited medical settings. Through extensive evaluations on medical visual question answering (Med-VQA) datasets, we show that our methodology improves localization-driven performance across different Med-VLM architectures. Our analysis of localization-based questions further reveals that improvements in anatomy and spatial reasoning directly enhance the overall accuracy of Med-VQA upto 6.2%. The proposed approach is model-agnostic and can be seamlessly integrated into existing Med-VLM pipelines. The dataset, code, and trained models will be made publicly available at https://github.com/CVLABLUMS/localizationlens.

0.73

Representation-guided in-context learning for medical image interpretation with multimodal large language models

cs.AI cs.CLcs.CV ·2026-09-21 ·Minda Zhao, Fangyu Hu, Yan Luo, Yutong Yang, Jiahui Cai +6 more
similarity 0.65
Abstract

Medical image interpretation is central to diagnosis and care, yet adapting general-purpose multimodal large language models (MLLMs) often requires resource-intensive domain-specific fine-tuning. Here we introduce representation-guided in-context learning (RG-ICL), a training-free inference framework that retrieves query-aligned demonstrations using frozen encoders, without task-specific parameter updates. Across eight datasets spanning histopathology, radiology and retinal fundoscopy, RG-ICL improved classification (mean gain 20 percentage points) and visual question answering (VQA) (mean gain 13 percentage points) over no-context and conventional ICL, approaching or exceeding training-based comparators. Which cases were retrieved mattered more than how many: 6 query-aligned cases outperformed up to 32 randomly selected ones, whereas fixed or random cases often reduced accuracy below baseline. For VQA, aligning reference cases with both image content and question intent produced further gains. These findings indicate that for medical image interpretation, curating which reference cases an MLLM sees is a practical alternative to retraining it.

0.16