CS Paper Radar

A 3D foundation model unifying CT interpretation and segmentation

Yulu Xie, Zilong Li, Shen Xu, Yifan Bai, Liuhong Shi, Jiao Chen, Xianglei Kong, Wenchao Zhu, Na Shen, Xianghua Ye, Yang Yan, Jiaju Zheng, Yunsong Peng, Yanzhou Su, Chaohui Yu, Hao Luo, Fan Wang

cs.CV ·submitted 2026-11-04 13:07 UTC · v1

Abstract

Radiologists interpret computed tomography (CT) scans by jointly determining what a finding represents and where it lies in three-dimensional (3D) anatomy. However, CT models have treated CT interpretation and 3D segmentation as separate tasks, leaving textual findings spatially unverifiable and overlooking potential synergy between clinical understanding and spatial perception. Here we present HoloCT, a generalist 3D foundation model unifying CT interpretation and voxel-level segmentation by jointly modelling whole-volume context and fine-grained anatomical detail, providing 3D masks as evidence. We curated HoloDATA, comprising 195,921 CT scans from 73 public datasets and six clinical cohorts, with 6.2 million instruction dialogues and 2.8 million CT-mask pairs. Across 346 tasks spanning segmentation, lesion screening, visual question answering, and report generation on 61 internal and 12 external datasets, HoloCT outperformed specialist and foundation models. In multicentre validation across 11,455 clinical CT scans from five hospitals, HoloCT outperformed competing models in lesion segmentation and report generation by 18.2 and 15.3 points. It also achieved 85.1% mean accuracy in screening thyroid tumours and colon lesions, exceeding all four participating radiologists in a retrospective reader study. Further analyses revealed bidirectional semantic-spatial synergy: language-guided segmentation delineated unseen anatomical structures and lesions as well as diffuse free-text findings, outperforming the leading approach by 22.1 points, whereas prompting the model to generate corresponding 3D masks alongside its textual outputs significantly improved interpretation performance. HoloCT shows that clinical understanding and spatial perception can be learned together within a single foundation model and offers a path towards more accurate and reliable CT analysis.

Comment
114 pages, including Supplementary Information; 7 main figures and 2 Extended Data figures

Closest papers

Nearest neighbours by meaning across the whole index.

Scaling 3D Visual Grounding in Abdominal CT

cs.CV cs.LG ·2026-10-02 ·Sam Church, Danyal Maqbool, Joshua D. Warner, Andrew Voter, Junjie Hu +2 more
similarity 0.72
Abstract

Visual grounding models can enhance radiology workflows by linking report findings to image regions. This is particularly valuable for 3D CT, where findings often occupy a tiny fraction of the volume. Training 3D grounding models requires large sets of paired phrases and regions, and building such datasets is expensive, requiring radiologists to annotate images by hand. We posit that this supervision is already created implicitly during routine reporting, as radiologists frequently place 2D annotations (e.g., distance measurement, arrows) on key images to make measurements and to support report interpretation. We introduce an automated pipeline that converts these routine clinical annotations into large-scale phrase-region supervision for 3D visual grounding. The pipeline links each annotation to the corresponding finding in the report through metadata matching, then uses a promptable 3D segmentation model to convert the 2D annotation into a volumetric mask. This produces phrase-mask-volume datasets without requiring additional radiologist annotation. Applied to a single institution's clinical picture archiving and communication system (PACS), our approach generated 105K phrase-mask-volume triplets from 59K abdominal CT exams. We also introduce two abdominal CT grounding benchmarks, LocusBench-Onc and LocusBench-ED, which comprise 240 oncology and 260 emergency-department radiologist-reviewed phrase-mask-volume triplets, respectively, with the latter spanning 13 distinct categories such as appendicitis, hematoma, and hernia. We further introduce LocusCT, a 3D visual grounding model trained on this dataset, which achieves hit rates of 0.725 on LocusBench-Onc and 0.773 on LocusBench-ED, substantially outperforming comparator models. These results show that routine PACS annotations are a scalable, previously unused source of supervision for 3D visual grounding.

0.08

HounsWorld: A Multimodal World Model for Hidden Patient-State Readout, Reconstruction, and Simulation

cs.CV ·2026-08-13 ·Yunhao Bai, Zhongwei Qiu, Guangyu Guo, Yiming Huang, Tony C. W. Mok +3 more
benchmarkcode/data similarity 0.71
Abstract

Clinical intelligence requires estimating a patient's underlying condition from incomplete observations rather than learning isolated mappings from scans to answers. Volumetric medical images provide dense observations of anatomy, attenuation, and lesions, whereas clinical language provides sparse but complementary semantic observations. We formulate CT-centered intelligence as inference over a shared latent patient state, under which readout, reconstruction, and simulation all become state-dependent prediction problems. To operationalize this view, we introduce HounsBench, a computed tomography (CT) centric patient-state benchmark that unifies these three task families with patient-disjoint splits and per-family metrics, and HounsWorld, a 3B multimodal world model that treats volumetric scans and language as observations of the shared state through Joint Understanding-Generation Learning. A shared transformer forms an implicit patient-state estimate and supports three outputs: query-conditioned answers that read out the state, reports and captions that reconstruct it in language, and condition-specific CT volumes for low-dose denoising, virtual contrast enhancement, and anatomy-constrained text-and-mask-to-volume generation. Zero-initialized CT adapters preserve pretrained multimodal mappings, while condition-explicit Hounsfield-unit window sampling exposes clinically meaningful density observations. HounsWorld shows strong performance across all three task families while consistently improving CT understanding through clinically structured completion. Our project is available at https://github.com/byhwhite/HounsWorld.git

0.24

RepConTUR: A Report-Conditioned Volumetric Multimodal Model for Abdominal Tumor Segmentation

cs.CV ·2026-10-29 ·Seunghwan Lee, Sangjoon Park, Jongmin Lee, Yoon Jo Kim, Wonyoung Cho +2 more
code/data similarity 0.71
Abstract · Submitted to CVPR 2027

Tumor delineation is required for radiotherapy planning, yet automatic segmentation is limited by errors, predominantly false positives, that distort dose and increase editing time. The radiology report accompanies the scan and localizes disease at the suborgan level, but existing text-promptable models condition on short referring phrases, and most operate in 2D. We present RepConTUR, a single native-3D early-fusion multimodal model that conditions volumetric abdominal tumor segmentation on the narrative report. We extend AbdomenAtlas 3.0 to a suborgan-level promptable segmentation dataset and generate report-based VQA pairs, yielding four report-derived tasks on the same annotations: referring segmentation (RES), report-grounded segmentation (GSEG), report generation (RRG), and visual question answering (VQA). We train RepConTUR, comprising a 3D CT encoder, an early-fusion language model, and a native-3D segmentation module, jointly on the four tasks. Across liver, kidney and pancreas, RepConTUR attains the highest Dice similarity coefficient (DSC), instance-wise precision, and detection F1 among the text-promptable baselines, and adding the report raises mean precision while leaving recall comparable. Against two vision-only specialists, nnU-Net and the report-supervised R-Super, RepConTUR attains the highest value on every in-domain metric for liver and pancreas and the highest mean DSC, recall, precision, and detection F1 over the four out-of-distribution public cohorts. Ablations indicate that conditioning on the narrative report raises detection F1 from 0.499 to 0.528 within the same model, that joint GSEG training raises RES F1 from 0.450 to 0.482, and that the native-3D segmentation module raises GSEG F1 from 0.139 to 0.528 over its 2D counterpart. Code is available at https://github.com/Oncosoft-Research/RepConTUR.

0.20

SAMI3D-DW: Interactive Segmentation of Any 3D Medical Images

cs.CV ·2026-09-22 ·Ping Gong, Shiyuan Su, Fandong Zhang, Xinchen Han, Haowei Sun +2 more
benchmark similarity 0.70
Abstract · 28 pages, 5 figures; replacement version with reordered category-level Dice scores presentation to better reflect clinical conventions., cla…

Interactive segmentation of 3D medical images supports quantitative analysis of anatomical structures and disease while allowing users to specify and refine their targets. Despite substantial progress by nnInteractive and VISTA3D, reliable segmentation across diverse clinical targets remains challenging, particularly for complex anatomical structures and the heterogeneous, long-tailed spectrum of pathology. We present SAMI3D-DW V1 (hereafter SAMI3D-DW), an interactive 3D segmentation model trained on Deepwise's large-scale proprietary medical image datasets. We evaluate the model under simulated user interactions on a CT/MR benchmark comprising 4,326 cases from 219 source datasets, spanning 107 anatomical and pathological categories, organized by a medical taxonomy and evaluated with a category-balanced DSC score. SAMI3D-DW achieves the highest category-macro Dice among evaluated methods in both interaction modes. With one point, it scores 0.5756 versus 0.5316 for nnInteractive, the strongest baseline, rising to 0.7771 versus 0.7495 with five points. With bounding-box initialization, the scores are 0.7129 versus 0.6530. After five corrective clicks, SAMI3D-DW reaches 0.8004 versus 0.7868. For radiologists and clinicians, SAMI3D-DW enables segmentation of complex anatomical structures, including intracranial vessel trees on CT and MR angiography, with a few clicks. In a preliminary in-house comparison involving neurofibromatosis type 1 (NF1), SAMI3D-DW-assisted tumor annotation took minutes per case and approximately one-fifteenth of the time required for manual annotation, highlighting its potential to support volumetric treatment-response assessment.

0.23

MetaStructAtlas: A Grounded 3D Vision-Language Dataset and Benchmark for Functional and Structural Reasoning in Whole-Body PET/CT

cs.CV ·2026-09-03 ·Chenguang Zheng, Le Xue, Yichi Zhang, Wenbo Zhang, Zehui Ling +6 more
benchmarkdataset similarity 0.70
Abstract

The joint interpretation of metabolic function and anatomical structure is essential for clinical diagnosis in whole-body PET/CT. Although recent advances in 3D medical vision-language models have demonstrated remarkable progress, current efforts are limited to regional CT imaging, leaving a critical void in comprehensive whole-body PET/CT analysis. In this work, we introduce MetaStructAtlas, a large-scale dataset for grounded whole-body PET/CT interpretation that synthesizes multimodal imaging with integrated anatomical, metabolic, and semantic annotations. MetaStructAtlas provides 490 co-registered 3D PET and CT volumes with 50,470 organ-level segmentation masks and grounded radiology reports. To facilitate interactive reasoning, we further developed MetaStructVQA, a standardized 3D grounded visual question-answering benchmark containing 100,565 QA pairs. This framework explicitly links diagnostic queries to visual evidence across modalities, encompassing anatomical, morphological, and metabolic characteristics. Finally, we evaluate state-of-the-art 3D medical VLMs on MetaStructVQA, establishing a robust foundation for multimodal representation learning and integrated whole-body reasoning in nuclear medicine.

0.24

Uni-Loc: Weakly Supervised 3D CT Pathology Localization via Spatially Grounded Vision-Language Classification

cs.CV ·2026-11-09 ·Hao-Chih Lee, Zahi A. Fayad, Xueyan Mei
similarity 0.70
Abstract

Accurate localization of abnormalities in three-dimensional (3D) CT scans is essential for linking automated predictions with clinically relevant pathological findings. We propose Uni-Loc, a vision-language framework that unifies pathology classification and 3D localization using scan-level supervision. Uni-Loc derives both predictions and localization maps from spatial similarities between pathology-conditioned queries and image features. A token-to-voxel upsampling module enables high-resolution localization, while gradient-guided thresholding identifies pathology regions without additional learned parameters. Evaluated on five localization tasks comprising 355 annotated CT scans, Uni-Loc achieves macro-averaged voxel-level AUROC/AUPR of 96.1\%/34.5\%, outperforming relevance propagation (80.7%/13.9%) and gradient saliency (88.7%/8.1%). Uni-Loc also achieves classification AUROC of 88.39% on CT-RATE and 78.03% on RAD-ChestCT, improving over a matched baseline. These results demonstrate effective 3D pathology localization without requiring pathology-specific voxel-level supervision.

0.12

Instance-Guided Report Anchoring for Text-Free 3D Abnormality Segmentation in Chest CT

cs.CV ·2026-08-31 ·Zhenyu Bu, Haoyan Ding, Chushu Shen, Xinyuan Zheng, Peiyu Duan +5 more
similarity 0.69
Abstract

Accurate 3D abnormality segmentation in chest CT requires dense spatial supervision, but obtaining expert voxel-level labels is costly. Radiology reports, however, are routinely generated during clinical interpretation and contain instance-specific descriptions that can provide additional guidance without new dense annotation. Existing vision-language grounding methods typically require report-derived findings at inference, making localization dependent on paired text and limiting each forward pass to a queried finding. We propose Instance-Guided Report Anchoring (IGRA), a model-agnostic module that preserves the correspondence between each annotated abnormality instance and the report finding that describes it. IGRA pools each instance representation and anchors it to the corresponding finding embedding during training; all text-related components are discarded at inference. We further reformulate free-text grounding on ReXGroundingCT as multi-label volumetric segmentation by merging same-category instances, allowing all abnormality categories to be predicted in one image-only forward pass. IGRA improves Dice by 22.5% over the strongest image-only baseline (30.93 vs. 25.25) and is comparable to VoxTell on the single-finding subset (30.29 vs. 30.43). Applied unchanged to four standard 3D segmentation backbones, IGRA improves Dice and hit rate across all architectures. Zero-shot evaluation on LIDC-IDRI, PleThora, and a private in-house dataset further shows consistent gains over image-only baselines.

0.17

NV-Reason-CT: 3D Visual Language Model for CT Analysis

cs.CV cs.AI ·2026-09-23 ·Andriy Myronenko, Dong Yang, Yucheng Tang, Baris Turkbey, Benjamin Simon +13 more
similarity 0.69
Abstract

We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.

0.16