CS Paper Radar

LHMCF-Net: A Learned Hyperbolic Mean Curvature Flow Network for Medical Images Segmentation

Shuangshuang Duan, Chunlei He, Shoujun Huang, Dexing Kong

cs.CV math-ph ·submitted 2026-08-21 10:05 UTC · v1

Abstract

Motivated by the classical Chan-Vese model and the ability of deep priors to capture complex spatial structures, we develop a segmentation model that leverages learned hyperbolic mean curvature flow (LHMCF) as a mathematical foundation for integrating feature space data fidelity and deep structural priors within a unified high-dimensional framework. The proposed LHMCF model is governed by a second-order dissipative hyperbolic PDE, where the introduction of a velocity field provides inertia and momentum to the evolving interface. This hyperbolic mechanism enables the contour to bypass noise-induced local minima and propagate coherently through low-contrast or ambiguous regions, addressing limitations inherent to first-order parabolic flows. To solve the continuous LHMCF model, we construct a deep unfolding network, named LHMCF-Net, which maps the iterative numerical procedure of the PDE into a sequence of discrete evolution stages. Each stage corresponds to one physically interpretable update of the underlying dynamical system, allowing the network to inherit the stability and geometric consistency of the PDE while supporting end-to-end optimization. Comprehensive experiments on three publicly available medical segmentation datasets demonstrate that LHMCF-Net achieves superior performance, particularly in challenging scenarios with low contrast and unclear boundaries. These results highlight the effectiveness of embedding hyperbolic geometric evolution into deep unfolding architectures and underscore the potential of physically inspired models for robust medical image segmentation.

Closest papers

Nearest neighbours by meaning across the whole index.

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

cs.CV cs.LGq-bio.QM ·2026-08-20 ·Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais
published similarity 0.66
Abstract · International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

0.23

M-Net: Integrating Spectral Features and Physical Field Operators into Deep Learning for Medical Image Segmentation

cs.CV cs.AI ·2026-08-12 ·Jing Zhu, Ye Wang, Fumin Wang
similarity 0.65
Abstract

Purpose: Deep learning-based medical image segmentation has achieved remarkable success, yet purely data-driven approaches often fail to exploit the rich mathematical structure inherent in medical images. We investigate whether explicit mathematical inductive biases, specifically matrix spectral analysis and vector calculus operators, can enhance segmentation beyond data-driven learning alone. Methods: We propose M-Net (Math-Augmented Network), which integrates three complementary mathematical priors into U-Net: (1) continuous spectral features derived from the condition number of centered local pixel matrices, providing a differentiable measure of texture ill-conditioning; (2) physical field operators (divergence and a discrete curl-like boundary irregularity operator) computed from image gradient fields, capturing focal intensity extrema and edge non-smoothness; and (3) a Math-Attention Gate (MAG) that adaptively fuses mathematical features with CNN-extracted deep features at skip connections. Results: Experiments on three benchmarks (LiTS, KiTS, and BraTS) show that M-Net achieves Dice scores of 78.42%, 76.15%, and 83.67%, outperforming baseline U-Net by 12.37%, 3.52%, and 5.55% on liver, kidney, and brain tumor segmentation, respectively. Ablations reveal that the condition-number feature contributes a 2.14% gain over binary invertibility features, while MAG adds 1.45% over simple concatenation. Conclusion: M-Net establishes that mathematical inductive biases provide effective complementary information for medical image segmentation. The continuous condition-number feature offers superior gradient information over discrete alternatives, and MAG preserves these priors throughout the network. This work opens avenues for integrating linear algebra and vector calculus into deep architectures for medical imaging.

0.04

O2D-MedNet: An Optimization-Aware Dual-Domain Framework for Robust Medical Image Segmentation

cs.CV ·2026-10-26 ·Shipeng Hu, Miaohui Wang, Jing Qin, Sukun Tian, Yuchun Sun
similarity 0.64
Abstract · 16 pages, 12 figures

Medical image segmentation (MIS) remains challenging due to composite degradations and multi-scale geometric variations, which jointly impair lesion-background separability, structural consistency, and optimization stability. Existing single-stream frameworks entangle heterogeneous cues within a single representation pathway, while hybrid-stream approaches often rely on generic or static fusion, limiting effective coordination across domains and failing to explicitly address optimization instability. To overcome these limitations, we propose a new optimization-aware dual-domain framework for MIS (O2D-MedNet). First, a degradation-aware dualdomain interaction (DDI) module integrates Fourier - and Wavelet-domain features to suppress degradation-sensitive responses while preserving structural and fine-detail information. Second, a cross-backbone contour-guided fusion (CGF) module enables selective interaction between CNN-based local detail modeling and visual state-space-based global structure modeling, improving boundary accuracy and representation consistency. Third, a gradient-context optimization (GCO) strategy stabilizes training by adaptively adjusting learning dynamics based on loss trends and gradient statistics, mitigating instability caused by class imbalance and heterogeneous sample difficulty. Extensive experiments on six benchmarks demonstrate consistent improvements over state-of-the-art MIS methods across multiple imaging modalities. Further analyses confirm enhanced sensitivity, structural consistency, and optimization stability, validating the effectiveness of the proposed O2D-MedNet for robust MIS under heterogeneous conditions.

0.20

Two-Parameter Flow Map Learning for Continuous-Time Diffeomorphic Image Registration

cs.CV ·2026-09-09 ·Mohammadjavad Matinkia, Nilanjan Ray
top venue similarity 0.64
Abstract · Published at European Conference on Computer Vision (ECCV), 2026

Diffeomorphic image registration is central to medical image analysis, enabling anatomically consistent alignment across subjects. Most learning-based diffeomorphic methods model autonomous ODEs(ordinary differential equations) by parameterizing a stationary velocity field and recovering deformations via scaling-and-squaring. While non-autonomous ODEs with time-dependent velocities increase expressiveness, existing approaches rely on numerical integration to implicitly enforce flow structure that entangles model expressiveness with discretization accuracy. We propose a framework to directly learn the continuous-time solution of a non-autonomous ODE formulated as a two-parameterflow map. By enforcing cocycle consistency, a fundamental structural property of time-varying flows, we learn the flow maps without time discretization and velocity integration during training. The framework recovers diffeomorphic mappings at inference using a small number of compositions. Our proposed framework seamlessly incorporates standard registration backbones and improves alignment accuracy consistently across nine datasets while preserving diffeomorphic structure. Notably, the proposed method achieves an average Dice improvement of 2.1% on brain MRI benchmarks, a 12% TRE reduction on lung CT, and a 2.6% Dice gain on cardiac MRI and ultrasound datasets.

0.46

Low-Rank Velocity Fields as a Structural Prior for Unsupervised 4D Medical Image Interpolation

cs.CV ·2026-08-25 ·Haojin Li, Hengzhuo Wang, Chang Liu, Zhiheng Ma, Heng Li +1 more
top venue similarity 0.62
Abstract · MICCAI 2026

Endpoint-only unsupervised 4D medical image interpolation synthesizes intermediate volumes from sparsely sampled sequences with only the start and end volumes available for training; however, this weakly constrained setting often yields intermediates with unstable boundaries and non-physiological motion, limiting interpretability and downstream analysis. We propose low-rank velocity fields as a structural prior, constraining motion to a structured Tucker low-rank velocity field space that decomposes motion into globally shared spatial bases and a compact sample-specific core, thereby encouraging spatially correlated, anatomy-consistent deformation while suppressing voxel-wise high-frequency artifacts. To capture global coordination and local non-rigid details, we model motion in a coarse-to-fine multi-scale scheme and compose scale-wise deformations at inference to synthesize volumes at arbitrary times. We further provide a theoretical analysis showing that, under Tucker parameterization, low-rank parameters control the smoothness energy of the velocity field, explaining why low-rank modeling promotes smoother motion. Experiments on ACDC and 4D-Lung demonstrate state-of-the-art performance, remaining competitive with methods trained with intermediate-frame supervision, and producing intermediates with improved structural coherence and more stable anatomical contours.

0.53

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.62
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.14

SymmAdapt: Symmetrical Flow Matching for Source-Free Domain Adaptation in Medical Image Segmentation

cs.CV ·2026-08-23 ·Tal Grossman, Noa Cahan, Hayit Greenspan
published similarity 0.62
Abstract · Accepted at SASHIMI 2026, held in conjunction with MICCAI 2026. To appear in the Springer LNCS proceedings of the MICCAI 2026 Satellite Even…

Domain shift across imaging modalities and acquisition sites remains a significant barrier to the clinical deployment of segmentation models. Source-free unsupervised domain adaptation (SFUDA) addresses this by adapting a pretrained model to an unlabeled target domain without requiring access to sensitive source data. We introduce a novel SFUDA framework built on Symmetrical Flow Matching, a unified generative model that segments an input image and synthesizes a source-like image from a mask within the same learned flow. By initializing inference from a domain-agnostic Gaussian origin, the model preserves structural consistency across domains and grounds predictions in learned anatomy rather than shifted texture statistics. Our pipeline leverages this symmetry to generate reliable pseudo-labels and corresponding source-like synthetic images from unlabeled target data, creating a generative replay buffer that anchors source knowledge during a generative self-training stage that fine-tunes on a joint set of real target and synthetic source-like images. We evaluate on abdominal multi-organ and cardiac segmentation, covering cross-modality MRI<->CT shifts, and multi-site prostate segmentation. Our approach outperforms SFUDA baselines and is competitive with conventional UDA methods.

0.25

Unsupervised Anatomical Feature Learning via Diffusion Models: Enhanced Medical Image Segmentation with Denoising Diffusion Probabilistic Models

cs.CV cs.AIcs.LG ·2026-08-26 ·Akshat G, Divyansh Gupta, Shaleen Bhatnagar, Shilpa Ankalaki, Tusar Kanti Mishra
similarity 0.62
Abstract · 15 pages, 5 figures. Submitted for peer review

Acquiring pixel-level annotations for medical image segmentation is a severe bottleneck. Traditional U-Net architectures, while effective, learn local texture patterns and lack awareness of global anatomical structures, leading to boundary delineation failures in low-data regimes. This research paper proposes utilizing unsupervised Denoising Diffusion Probabilistic Models (DDPMs) to extract anatomical features. We train a DDPM on 21 unlabeled abdominal CT scans to learn structural representations, transferring the encoder weights to a downstream segmentation task evaluated on the BTCV multi-organ dataset. Diffusion pretraining significantly improved liver segmentation: Dice increased from $0.75\pm0.36$ to $0.93\pm0.16$ ($p < 5.33\times10^{-26}$, 0.529 Cohen's d), Average Surface Distance (ASD) decreased by 66%, and 95th-percentile Hausdorff Distance (HD95) reduced by 45%. For kidney segmentation, Dice improved from $0.90\pm0.19$ to $0.95\pm0.10$ ($p < 4.01\times10^{-11}$). Multi-organ pooled performance showed a 68% variance reduction and a 74% improvement in boundary precision (Dice $0.95\pm0.07$). Crucially, frozen encoder models retained > 80% of fine-tuned performance without exposure to segmentation labels, proving the existence of learned anatomical priors. In low-data scenarios, diffusion-pretrained models maintained robust performance with only 50% (Dice: 0.92 liver, 0.94 kidney), 25%, and even 10% (Dice: 0.89 liver, 0.71 kidney) of labeled data. Using unlabeled images for diffusion-based pretraining successfully embeds robust anatomical features prior to human supervision, transforming U-Nets into anatomy-aware systems.

0.21