CS Paper Radar

Steer the Sampling, Not the Kernel Grid: Geometry-Guided Sampling Operator for Volumetric Segmentation

Sizhe Wang, Himashi Peiris, Zhaolin Chen

cs.CV ·submitted 2026-08-26 14:01 UTC · v1
top venue

Abstract

Accurate 3D segmentation is central to quantitative lesion assessment and anatomy mapping for clinical planning and follow-up. Thin, elongated, and fine anatomical/pathological structures (e.g., vessels) are a particularly challenging case: a one-voxel boundary error can disconnect a branch and change clinically relevant topology. In encoder-decoder networks (e.g., U-Net), repeated downsampling and fixed-grid convolution blur or alias fine structures and weaken orientation cues, so early mistakes propagate across scales. We propose a geometry-guided local operator that steers where features are sampled, rather than deforming convolutional kernels, under a single formulation for both feature refinement (stride 1) and resolution reduction (stride > 1). At each voxel, it predicts a local orientation and bounded step sizes, samples symmetrically along these directions, and transforms paired samples into compact geometric and boundary cues with lightweight mixing; a cross-scale consensus aligns encoder and decoder features at skip connections to reduce geometric mismatch. Replacing all stride 1 and stride 2 operators in a 3D U-Net yields consistent improvements on BraTS, MSD Hepatic Vessel, and TDSC-ABUS, with notably better boundary metrics (e.g., BraTS Dice 86.1 to 88.9, HD95 7.1 to 6.2; TDSC-ABUS HD95 39.1 to 27.8) while reducing parameters from 2.3M to 0.8M. We further demonstrate that the operator can be integrated into other backbones (e.g., nnU-Net, Swin-UNETR, and MedNeXt) without changing their macro-architectures while providing consistent performance gains.

Comment
Accepted at MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

UniPro: Unified Multi-Mode Medical Image Segmentation from 2D Images to 3D Volumes via Propagation

cs.CV ·2026-10-03 ·Bangwei Guo, Yunhe Gao, Meng Ye, Yang Zhou, Difei Gu +3 more
similarity 0.73
Abstract

Medical image segmentation remains fragmented along two axes: segmentation paradigms and data dimensionality. Existing methods are typically developed separately for semantic, in-context, and interactive segmentation, and are further specialized to either native 2D images or 3D volumetric data. In clinical practice, however, segmentation workflows take many forms: a case may be initialized by semantic prediction, reference-guided segmentation, or user interaction. Regardless of how it begins, fine-grained refinement is naturally performed on 2D views; for volumetric scans, such 2D edits must propagate coherently to the rest of the volume. We present UniPro, a unified model that bridges segmentation paradigms and data dimensionality, using propagation to extend 2D segmentation to 3D volumes. Our key insight is that volumetric propagation and in-context segmentation share the same reference-conditioned prediction mechanism, differing only in whether the reference image-mask pairs come from other cases or from previously segmented neighboring slices. Building on this view, UniPro supports semantic, in-context, interactive, and propagation-based segmentation within a single slice-based framework, using class priors, reference exemplars, user clicks, and neighboring-slice predictions as mode-specific conditioning inputs. To improve propagation reliability, UniPro further incorporates bidirectional and 3D supervision to regularize slice-wise propagation beyond per-slice losses. Extensive experiments across diverse modalities and anatomies show that UniPro achieves strong performance across all segmentation settings, enabling annotation-efficient 3D segmentation from sparse 2D initialization and reducing slice-by-slice correction effort.

0.13

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.73
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23

Flow Matching Meets 3D Curvilinear Structure Segmentation in Medical Imaging

cs.CV cs.LGq-bio.QM ·2026-08-20 ·Sidi Mohamed Sid'El Moctar, Nicolas Vitry, Hélène Bouvrais
published similarity 0.71
Abstract · International Workshop on Machine Learning in Medical Imaging (MLMI 2026) @ MICCAI

Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology. While deep learning approaches for 3D curvilinear segmentation have been proposed, they are often tailored to specific anatomies or modalities, limiting generalization across clinical settings and leaving room for improvement. Recent generative models have shown the benefits of iterative prediction for structured segmentation tasks, yet diffusion-based methods suffer from computationally expensive sampling, hindering their use on high-resolution 3D volumes. We present 3D-CurvSegFlow, a flow matching-based model for 3D curvilinear structure segmentation. The model learns a continuous transformation from a simple source distribution to the target vascular representation, enabling progressive refinement of complex curvilinear geometries with efficient inference. We evaluate our method on Three public challenging datasets covering distinct anatomies and modalities: portal vein, cerebral vessel, and coronary arteries. Using a common architecture and training strategy across all tasks, our method outperforms general-purpose and vessel-specific approaches, with strong preservation of thin branches and vascular continuity. This work not only advances the state-of-the-art in 3D curvilinear segmentation but also opens new avenues for efficient, generalizable, and clinically applicable methods in medical image analysis.

0.23

SlimFormer++: Token Mixing Where It Matters for Efficient 3D Medical Image Segmentation

cs.CV ·2026-10-18 ·Yang Hong, Lei Zhang, Zhihong Liu, Jianqing Mo, Xujiong Ye
code/data similarity 0.71
Abstract

To determine where computation is needed in volumetric segmentation networks, we analyze block-level redundancy and stage-wise token-mixer contribution. Centered Kernel Alignment reveals high input-output representational similarity within blocks of representative convolutional, hybrid, and Transformer-style segmentation networks. Similarity-guided pruning reduces their parameter counts by 39-75% while decreasing mean Dice by less than 0.4 percentage points. To examine token mixers within blocks, we introduce Anatomical Relation Distortion, which quantifies how bypassing a mixer distorts feature relations between labeled anatomical positions. Applied to an unpruned candidate architecture, Centered Kernel Alignment indicates high representational redundancy in intermediate encoder mixers, whereas Anatomical Relation Distortion shows that they contribute little and the bottleneck mixer most. These findings motivate SlimFormer++, which uses Selective Mixing blocks with windowed Mamba mixing in the first encoder stage and only residual channel MLPs in deeper stages. At the bottleneck, Augmented Mixing injects similarity-weighted sparse long-range context into the axial taps of a depthwise convolution at cost linear in voxel count. Evaluated against 12 baselines across eight public CT, MRI, and ultrasound datasets (1,809 cases), SlimFormer++ achieves the highest mean Dice (87.84%) and lowest mean HD95 (6.50 mm) with the fewest parameters (5.98 million). These results support stage-aware token mixing as a design strategy for improving the accuracy-efficiency trade-off in volumetric segmentation. The source code is available at https://github.com/WHHHHHY822/SlimFormerPlusPlus

0.33

CoInS-Net: A Continuous Position-Aware Network for Joint Medical Image Interpolation and Segmentation

cs.CV ·2026-08-10 ·Yujia Sun, Ningfeng Que, Peiting Shi, Rongrong Fu, Yingying Yang +2 more
similarity 0.70
Abstract

Accurate medical image interpolation and anatomical structure segmentation are fundamental for computer-aided diagnosis and treatment planning. Anisotropic medical volumes with sparse through-plane sampling often suffer from structural discontinuity and boundary blur, hindering reliable clinical image analysis. Most existing methods implement interpolation and segmentation independently, which introduces redundant computation and fails to fully exploit complementary cross-slice structural information between sequential slices. To address these issues, we propose a continuous position-aware interaction network, termed CoInS-Net, for joint frame interpolation and lesion segmentation. Unlike conventional cascaded interpolation-then-segmentation paradigms, the framework enables bidirectional interaction under a shared Swin encoder with continuous spatial coordinate queries. A spatially continuous position interpolation module generates target-position features at every scale from the relative coordinate and physical spacing, and a prototype-based task mutual interaction module lets the segmentation and interpolation branches exchange global structure through a small set of shared prototypes rather than dense feature mixing. A multi-scale task-cooperative decoder further separates each scale into shared and task-specific components, so the two tasks reinforce common anatomy while preserving their distinct requirements down to the boundary level, without extra annotations. Experiments on four public medical imaging datasets with diverse modalities and anatomical regions demonstrate that the proposed method outperforms conventional single-task schemes. The joint optimization framework effectively realizes mutual promotion between interpolation and segmentation tasks, providing a reliable and universal technical scheme for intelligent clinical medical image analysis.

0.34

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.70
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.14

Where to Look Matters: Rethinking Sub-Volume Sampling in 3D Medical Self-supervised Learning

cs.CV ·2026-10-09 ·Junkai Liu, Le Zhang
publishedcode/data similarity 0.70
Abstract · NeurIPS 2026. Project page: https://volumeprobe.github.io/

Self-supervised learning on 3D medical images commonly relies on random sub-volume sampling during pretraining. However, random cropping implicitly treats all spatial regions as equally worth observing, despite anatomical priors and spatial redundancy that make regions inherently unequal in their value for representation learning. To this end, we first show through controlled crop-quality manipulations that better sub-volumes lead to better downstream transfer, revealing the observation policy as an overlooked bottleneck in 3D medical SSL. Motivated by this finding, we revisit sub-volume sampling as a where-to-look problem. We propose VolumeProbe, a plug-and-play framework that replaces random cropping with an offline coarse-to-fine probe bank guided by anatomy-awareness, informativeness, and diversity. We instantiate VolumeProbe as a lightweight Lite variant using geometric and image-statistical cues, and a diagnostic Feat variant using frozen visual features, to examine whether lightweight volume-intrinsic priors suffice or richer semantic cues reliably provide additional value. Extensive experiments across multiple 3D medical SSL backbones and downstream tasks demonstrate that VolumeProbe-Lite consistently improves transfer performance over random sampling. Mechanistic analyses further link these gains to more anatomically plausible and informative observations, reduced spatial redundancy, more efficient learning dynamics, and more structured representations.

0.22

Really Need Recursion? Revisiting One-pass Registration with Multi-level Multi-space Contextual Guidance

eess.IV cs.AI ·2026-10-15 ·Yue Lin, Shenghai Wu, Mingyuan Meng
top venue similarity 0.70
Abstract · Accepted at MICCAI 2026

Deformable image registration is a fundamental challenge in medical image analysis. Recent deep learning-based methods typically adopt either one-pass architectures that complete registration in a single network iteration, or recursive architectures that refine registration through multiple passes. While recursive methods often improve accuracy, they incur substantial computational overhead and slower inference speed. In this paper, we challenge the necessity of recursion for high-performance deformable registration and propose M2CG, a one-pass registration network with Multi-level Multi-space Contextual Guidance. It performs multi-step progressive pyramid registration within a single iteration, guided at each step by contextual cues from three levels (previous, current, and subsequent steps) and four spaces (image space, image feature space, segmentation space, and segmentation feature space). Our M2CG supports both unsupervised (without any labels) and semi-supervised (with segmentation labels for partial training data) registration, and has achieved state-of-the-art performance across two well-benchmarked inter-/intra-patient medical registration tasks with eight public datasets. Our findings suggest that the current reliance on recursion may stem from the absence of sufficient contextual cues that comprehensively characterize the remaining distance to the target alignment.

0.31