CS Paper Radar

SlimFormer++: Token Mixing Where It Matters for Efficient 3D Medical Image Segmentation

Yang Hong, Lei Zhang, Zhihong Liu, Jianqing Mo, Xujiong Ye

cs.CV ·submitted 2026-10-18 19:19 UTC · v1
code/data

Abstract

To determine where computation is needed in volumetric segmentation networks, we analyze block-level redundancy and stage-wise token-mixer contribution. Centered Kernel Alignment reveals high input-output representational similarity within blocks of representative convolutional, hybrid, and Transformer-style segmentation networks. Similarity-guided pruning reduces their parameter counts by 39-75% while decreasing mean Dice by less than 0.4 percentage points. To examine token mixers within blocks, we introduce Anatomical Relation Distortion, which quantifies how bypassing a mixer distorts feature relations between labeled anatomical positions. Applied to an unpruned candidate architecture, Centered Kernel Alignment indicates high representational redundancy in intermediate encoder mixers, whereas Anatomical Relation Distortion shows that they contribute little and the bottleneck mixer most. These findings motivate SlimFormer++, which uses Selective Mixing blocks with windowed Mamba mixing in the first encoder stage and only residual channel MLPs in deeper stages. At the bottleneck, Augmented Mixing injects similarity-weighted sparse long-range context into the axial taps of a depthwise convolution at cost linear in voxel count. Evaluated against 12 baselines across eight public CT, MRI, and ultrasound datasets (1,809 cases), SlimFormer++ achieves the highest mean Dice (87.84%) and lowest mean HD95 (6.50 mm) with the fewest parameters (5.98 million). These results support stage-aware token mixing as a design strategy for improving the accuracy-efficiency trade-off in volumetric segmentation. The source code is available at https://github.com/WHHHHHY822/SlimFormerPlusPlus

Closest papers

Nearest neighbours by meaning across the whole index.

Steer the Sampling, Not the Kernel Grid: Geometry-Guided Sampling Operator for Volumetric Segmentation

cs.CV ·2026-08-26 ·Sizhe Wang, Himashi Peiris, Zhaolin Chen
top venue similarity 0.71
Abstract · Accepted at MICCAI 2026

Accurate 3D segmentation is central to quantitative lesion assessment and anatomy mapping for clinical planning and follow-up. Thin, elongated, and fine anatomical/pathological structures (e.g., vessels) are a particularly challenging case: a one-voxel boundary error can disconnect a branch and change clinically relevant topology. In encoder-decoder networks (e.g., U-Net), repeated downsampling and fixed-grid convolution blur or alias fine structures and weaken orientation cues, so early mistakes propagate across scales. We propose a geometry-guided local operator that steers where features are sampled, rather than deforming convolutional kernels, under a single formulation for both feature refinement (stride 1) and resolution reduction (stride > 1). At each voxel, it predicts a local orientation and bounded step sizes, samples symmetrically along these directions, and transforms paired samples into compact geometric and boundary cues with lightweight mixing; a cross-scale consensus aligns encoder and decoder features at skip connections to reduce geometric mismatch. Replacing all stride 1 and stride 2 operators in a 3D U-Net yields consistent improvements on BraTS, MSD Hepatic Vessel, and TDSC-ABUS, with notably better boundary metrics (e.g., BraTS Dice 86.1 to 88.9, HD95 7.1 to 6.2; TDSC-ABUS HD95 39.1 to 27.8) while reducing parameters from 2.3M to 0.8M. We further demonstrate that the operator can be integrated into other backbones (e.g., nnU-Net, Swin-UNETR, and MedNeXt) without changing their macro-architectures while providing consistent performance gains.

0.24

TRIUNE-Net: Harmonizing Scale, Shape, and Efficiency in Pancreatic Tumor Segmentation

cs.CV ·2026-09-08 ·Amir Hossein Saleknia, Alireza Kheyrkhah, Sanaz Karimijafarbigloo, Reza Azad, Sina Houshmand +3 more
code/data similarity 0.67
Abstract

Pancreatic tumor segmentation in 3D CT volumes is challenged by extreme scale variability across both the pancreas and tumor, and highly irregular tumor morphology. While recent advances have pushed segmentation performance, existing methods do not explicitly address these challenges and come at the cost of excessive computational complexity, limiting their practicality in resource-constrained clinical environments. We propose TRIUNE-Net, a lightweight unified architecture that harmonizes scale, shape, and efficiency through three synergistic innovations. A multi-scale context aggregation module with stage-adaptive dilated convolutions enables the model to reason across the broad range of anatomical scales present in both organs. A serial linear-deformable attention mechanism combines large effective receptive fields with shapeadaptive deformable convolutions to capture irregular, non-convex tumor morphologies. Finally, an information-preserving downsampling module replaces conventional max pooling entirely, retaining all spatial information while adding negligible parameters, preventing small tumors from being discarded before they can be recognized. On both the MSD Pancreas and NVD Pancreas datasets, TRIUNE-Net achieves state-of-theart results with only 5.86 M parameters and no external pre-training, outperforming all baselines across all key tumor metrics. Specifically, it surpasses the next-best model by 0.45% in tumor Dice, 6.0 points in F1 score, 6.6 points in sensitivity, and 3.4 points in precision, simultaneously reflecting its ability to suppress both missed tumors and false alarms in clinically realistic conditions. Our code is available at: https://github.com/abdora-ai/TRIUNE-Net

0.30

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

cs.CV ·2026-08-25 ·Sebastián González, Karen Sanchez, José M. Saavedra, Marcelo Pizarro, Bernard Ghanem
published similarity 0.65
Abstract · Published at MedAGI in MICCAI 2026

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

0.25

A General-Purpose Dual-Path Interaction Framework for Multi-View Medical Image Segmentation: Alleviating Data Volume Dependency in Small-Sample Regimes

cs.CV ·2026-10-22 ·Shuhuan Wang, Yuanyuan Cui, Pengju Wang, Huimin Guo, Ling Yue +8 more
similarity 0.64
Abstract · 20 pages, 5 figures

The performance of medical image segmentation depends on a large amount of annotated data, and most segmentation models experience a significant drop in performance in low-sample-size scenarios. Existing semi-supervised and weakly supervised methods rely on specific network architectures, while traditional multi-view-assisted segmentation methods require strictly paired samples, which limits their clinical applications. To address these issues, we propose DPIF, a general-purpose plug-and-play dual-path interaction framework compatible with arbitrary encoder-decoder segmentation networks, which leverages cross-view anatomical complementarity to reduce annotation reliance. DPIF first performs Sinkhorn optimal transport-based cross-view distribution alignment to establish global semantic correspondence without sample-level pairing. It then adopts conditional mutual information-guided feature decoupling to enable bidirectional knowledge transfer only within the shared semantic space, suppressing view-specific noise. Finally, persistent homology-based topological regularization encodes anatomical invariants as unsupervised priors to mitigate overfitting. Experiments were conducted using 24 baseline models on a private multicenter echocardiography dataset and two public datasets. The results show that DPIF-enhanced models outperform single-view baseline models when trained on comparable amounts of data. Notably, most dual-path variants trained on 40\% - 60\% of the data achieve performance comparable to that of single-view models trained on the full dataset. This demonstrates that DPIF provides a general-purpose and scalable solution for data-scarce multi-view medical image segmentation problems.

0.26

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.64
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

cs.CV cs.AI ·2026-11-07 ·Szymon Płotka, Gizem Mert, Pedro R. A. S. Bassi, Wenxuan Li, Zongwei Zhou +7 more
publishedcode/data similarity 0.64
Abstract · NeurIPS 2026

Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop. We propose Anatomy-Activated Mixture-of-Experts (A$^{2}$MoE), a framework that incorporates anatomical inductive biases within the model's computational path. A$^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical composition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}$MoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A$^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning. The code is available at https://github.com/gmum/A2MoE.

0.41

MCSeg: Pre-training and Fine-tuning Volumetric Pyramid Transformer for Multi-modal Cardiac Image Segmentation

cs.CV ·2026-08-31 ·Zhiyu Ye, Hairong Zheng, Tong Zhang
publishedcode/data similarity 0.64
Abstract · Accepted for publication in IEEE Journal of Biomedical and Health Informatics

Automatic cardiac image segmentation is pivotal for diagnosing and treating cardiac diseases. In this work, we introduce MCSeg, a volumetric transformer-based network tailored for multi-modal cardiac segmentation. To overcome the architectural mismatch inherent in existing hybrid networks, we propose a novel Scaling Feature Pyramid (SFP). Unlike conventional skip connections, the SFP effectively bridges the single-scale 3D Vision Transformer (ViT) encoder and the multi-scale CNN decoder by transforming the ViT's output into a hierarchical feature pyramid, ensuring that global contextual information is effectively leveraged. For the training paradigm, the ViT encoder first undergoes self-supervised pre-training via masked image modeling. Subsequently, the network is fine-tuned on downstream tasks, during which a regional mutual information (RMI) loss is integrated to improve boundary segmentation accuracy. In experiments, MCSeg consistently outperforms eleven SOTA methods on CT dataset ImageCHD, multi-modal dataset MM-WHS, MRI dataset HVSMR-2.0 and MSD Heart, highlighting the effectiveness of our MCSeg for multi-modal cardiac segmentation tasks. Furthermore, MCSeg's superior performance in few-shot experiment showcases its significant potential in adapting to limited data scenarios. Codes and pre-trained ViT-B weights are open-sourced at https://openi.pcl.ac.cn/OpenMedIA/MCSeg

0.40

MaLViL: Multi-axis Low-rank Vision-LSTM for Medical Image Segmentation

cs.CV ·2026-08-18 ·Afshin Bozorgpour, Sina Ghorbani Kolahi, Moein Heidari, Ilker Hacihaliloglu, Dorit Merhof
publishedcode/data similarity 0.64
Abstract · Accepted at the MICCAI Workshop on Machine Learning in Medical Imaging (MLMI), 2026

Vision-LSTM (ViL) enables efficient global modeling, but its cost still scales with the number of spatial tokens, so existing segmenters confine ViL to a coarse bottleneck and lose fine anatomical detail. Rasterizing 2D features into a 1D sequence further breaks adjacency across the orthogonal scan axis. We propose MaLViL, a Multi-axis Low-rank Vision-LSTM network that extends ViL across decoder resolutions. Bidirectional low-rank ViL (Bi-LRViL) reasons on a compact orthonormal subspace and preserves detail through an orthogonal residual; scale-aware SaLViL restores cross-axis neighbors before serialization; and a Cross-Directional Mixer (CDM) fuses orthogonal horizontal and vertical traversal paths. Statistics-Guided Skip Modulation (SGSM) further retains boundary cues in encoder skips. On skin-lesion, ultrasound, and multi-organ CT benchmarks, MaLViL achieves competitive or state-of-the-art segmentation accuracy, while reducing ViL operator memory by up to $83\times$ at fine decoder resolutions. Code is available at: https://github.com/xmindflow/malvil.

0.40