CS Paper Radar

SPARC: Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI

Arnaud Boutillon, Naomi Clarke, Tomas Woodgate, Daniel West, Alina Schneider, Rachael Franklin, Anthony Price, Jo Hajnal, Kuberan Pushparajah, David Lloyd, Maria Deprez

cs.CV ·submitted 2026-08-19 07:07 UTC · v1

Abstract

Fetal cardiac MRI (fCMR) provides valuable diagnostic information complementary to echocardiography, particularly for complex congenital heart disease (CHD). Dynamic cine imaging captures cardiac motion essential for assessment of cardiac function; however, the reconstruction of 3D+time cine volumes from 2D+time acquired slices remains challenging due to unpredictable fetal motion and the absence of automated and robust processing tools suitable for clinical deployment. We present the SPARC pipeline (Slice-to-volume Pipeline for Automated Reconstruction of gated 3D+time fetal Cardiac MRI) which combines physics-informed slice-to-volume reconstruction (SVR) of Doppler ultrasound (DUS) gated stacks of slices, assisted by deep learning (DL) models for thoracic segmentation and anatomical reorientation. The proposed SVR algorithm achieves a tenfold reduction in reconstruction time relative to existing frame-wise approaches ($4.8 \pm 1.0$ vs $49.0 \pm 14.1$ min, $p < 0.0001$) while improving the reconstruction quality. Thoracic segmentation performance using ensemble aggregation exceeded inter-rater agreement (Dice $84.7 \pm 3.9\%$ vs $81.4 \pm 7.7\%$, $p<0.05$), while anatomical reorientation achieved a success rate of $90.1\%$. End-to-end evaluation on a large held-out clinical cohort ($n = 121$) demonstrated fully automatic processing in $82.6\%$ of cases with a mean runtime of $7.1 \pm 1.3$ min, compatible with clinical deployment. The complete SPARC pipeline is publicly available as a Docker container https://hub.docker.com/r/aboutill/sparc and is currently deployed at our institution as a clinical research tool.

Closest papers

Nearest neighbours by meaning across the whole index.

SV-Cine: Diagnosis-Conditioned Segmentation of Single Ventricle Physiology via Generative Data Augmentation

cs.CV physics.med-ph ·2026-09-11 ·Lila Cunge
similarity 0.74
Abstract · arXiv admin comment: This version has been removed by arXiv administrators as the submitter did not have the rights to agree to the license …

Single Ventricle Physiology (SVP) is a rare subtype of congenital heart disease characterized by the presence of a single functional cardiac ventricle with atypical anatomic configurations that challenge conventional image segmentation approaches. The scarcity of clinical data and the morphological diversity across SVP subtypes make the development of robust segmentation methods particularly difficult. To address these limitations, we propose a cardiac MRI segmentation framework focused on ventricular chambers and myocardium segmentation tailored for SVP. First, we introduce a data augmentation pipeline that generates synthetic 3D cardiac meshes using SDF4CHD and corresponding synthetic cardiac MRI through generative modeling. Second, we introduce SV-Cine, a diagnosis-conditioned adaptation of the foundation model CineMA that incorporates patient-level diagnostic information through Feature-wise Linear Modulation layers, enabling diagnosis-aware feature adaptation during segmentation. We evaluated the framework on an internal cohort with varying SVP subtypes. SV-Cine achieved median Dice scores of 0.89 (IQR: 0.80--0.91) for the left ventricle and 0.72 (IQR: 0.54--0.84) for the right ventricle, outperforming the strongest baseline, nnU-Net, by 0.39 Dice points on right ventricle segmentation. It also yields a median ejection fraction error of 5.55 percentage points (IQR: 3.41--7.69) for the dominant ventricle. Compared with the internal cohort, LV and myocardium segmentation performance was lower for the external cohort; whereas RV Dice scores were comparable for both cohorts. Our findings suggest that a pretrained foundation model can be adapted for highly specialized downstream tasks through usage of diagnosis priors while leveraging anatomic knowledge learned from large-scale MRI datasets during pretraining.

0.12

Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI Reconstruction

cs.CV ·2026-10-06 ·Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
publishedcode/data similarity 0.66
Abstract · Accepted at ECCVW 2026

Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while preserving diagnostic fidelity. Recent reconstruction methods are typically trained from scratch and often require large amounts of task-specific data, limiting their robustness under data scarcity and distribution shifts. In this work, we investigate whether pretrained vision foundation models can serve as effective priors for accelerated cardiac MRI reconstruction. We propose a reconstruction framework that integrates frozen and parameter-efficiently adapted visual encoders, including CLIP, BiomedCLIP, and DINOv2, within a transformer-based reconstruction architecture. Extensive experiments on the CMRxRecon2023 and CMRxRecon2024 benchmarks demonstrate that pretrained representations consistently outperform a transformer trained from scratch across multiple acceleration factors. We further evaluate performance under limited supervision and cross-dataset transfer, showing that foundation models provide superior data efficiency and generalization. While frozen representations are particularly effective in extreme low-data regimes, Low-Rank Adaptation (LoRA) yields additional gains when moderate amounts of training data are available. Among the evaluated backbones, DINOv2 achieves the strongest overall performance. These findings highlight the potential of vision foundation models as robust and transferable priors for cardiac MRI reconstruction.

0.31

Beyond In-Distribution Metrics: A Systematic Out-of-Distribution Evaluation of Congenital Heart Disease Segmentation

cs.CV cs.AI ·2026-09-15 ·Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya +3 more
published similarity 0.66
Abstract · 12 pages, 6 figures, 2 tables. Accepted at STACOM 2026, held in conjunction with MICCAI 2026

Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Although deep-learning methods can automate this process, they are typically evaluated in-distribution, despite clinically relevant shifts in scanner, protocol, institution, population, and imaging modality. We present, to our knowledge, the first systematic evaluation of out-of-distribution (OOD) generalization in CHD segmentation, using ImageCHD as a held-out target cohort. We compare representative segmentation architectures under combined CT and CMR training, CT-only training, self-supervised pretraining, and limited target-domain adaptation. In-distribution performance proves to be a poor indicator of cross-cohort robustness: nnU-Net achieves the highest validation Dice (0.77) but falls to 0.51 on ImageCHD, while SwinUNETR generalizes substantially better, reaching 0.67 Dice. MAE and JEPA pretraining provide only modest additional benefit, suggesting that architecture contributes more to robustness than the tested pretraining strategies in this setting. When limited target-domain supervision is introduced, all SwinUNETR variants exceed 0.76 Dice with only 11 labeled ImageCHD cases. These findings demonstrate that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation.

0.28

Anatomy-Aligned Surface Field Learning for Myocardial Reconstruction from Sparse Short-Axis Cine MRI

cs.CV ·2026-09-24 ·Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
code/data similarity 0.65
Abstract · 12

Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis (SAX) cine MRI is sparsely sampled along the through-plane direction, making dense and anatomically consistent surface reconstruction challenging. In this study, we propose an anatomy-aligned surface learning framework that parameterizes the epicardial and endocardial surfaces on a shared circumferential-longitudinal UV domain. This formulation converts irregular 3D reconstruction into structured coordinate-field completion with explicit correspondence across subjects and cardiac phases. Sparse SAX contours are encoded as UV observation fields, coverage-aware sampling improves robustness to incomplete slice coverage, and topology- and distortion-aware learning preserves circumferential continuity and local surface quality. Experiments on three public cine MRI datasets showed that the proposed method consistently outperformed representative mesh-based and implicit reconstruction approaches, achieving overall Chamfer distances of $2.887$~mm on ACDC, $2.641$~mm on M\&Ms, and $2.810$~mm on M\&Ms-2. The reconstructed sequences also preserved ventricular function, with end-diastolic volume and ejection fraction errors of $3.3$~mL and $1.1 \%$, respectively. These results demonstrate that anatomy-aligned UV learning provides an accurate, efficient, and correspondence-aware representation for sparse cine MRI reconstruction and myocardial modeling. The source code will be available at https://github.com/yuan-xiaohan/SAX2MyoSurf.

0.23

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.65
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.16

FM-Recon: Exploring Foundation Model Features for Accelerated Cardiac Cine MRI Reconstruction

cs.CV cs.AI ·2026-11-16 ·Donghang Lyu, Marius Staring, Ruochen Gao, Jochen Keupp, Hildo J. Lamb +1 more
similarity 0.65
Abstract

Foundation models have demonstrated strong feature extraction capabilities across various medical imaging tasks, yet their potential for MRI reconstruction remains largely unexplored, particularly within unrolled reconstruction networks and under artifact-corrupted inputs. In this work, we explore whether and how features from pretrained foundation models can benefit accelerated cardiac cine MRI reconstruction. To this end, we propose FM-Recon, a framework that refines and integrates extracted features from frozen image encoder of foundation models into an unrolled reconstruction network. Through extensive experiments on the CMRxRecon2023 dataset, we systematically evaluate foundation model features across different reconstruction settings. Our results show that foundation models can extract informative representations from artifact-corrupted inputs and improve reconstruction performance, particularly at moderate acceleration factors. These findings demonstrate the potential of foundation model features for accelerated MRI reconstruction and provide insights into their effective integration into unrolled reconstruction networks.

0.09

AI-Based Multi-View Echocardiographic Image Synthesis using Dynamic Shape Control

cs.CV cs.AI ·2026-11-13 ·João Freitas, Anca Balinisteanu, Ahmed Youssef, Vitor Hugo Pereira, Jan D'hooge +1 more
published similarity 0.65
Abstract · 5 pages, 2 figures, accepted for publication in the Proceedings of the 2026 IEEE International Ultrasonics Symposium (IUS 2026)

Although automated methods have improved echocardiographic workflows, progress remains constrained by the need for large, well-annotated datasets. As the development of clinical databases is often limited by ethical and logistical challenges, synthetic data generation has emerged as a promising alternative. However, existing approaches commonly rely on left ventricle shape-based supervision or are tailored to specific cardiac views, limiting the generation of additional standard and unconventional imaging planes and the preservation of multi-view consistency across cardiac chambers. To address these limitations, we propose a novel framework for shape-controlled synthesis of multi-view echocardiographic sequences. First, multi-view cross-sections are extracted from dynamic whole-heart meshes. Ultrasound-like appearance is then introduced through a two-stage AI-based pipeline. In Stage 1, an unpaired GAN-diffusion model translates these cross-sections into realistic echocardiographic frames. As this translation is performed independently at the frame level, Stage 2 employs masked video reconstruction to improve temporal coherence and cardiac motion. Evaluation demonstrated high frame-level realism for both stages, while the integration of Stage 2 substantially improved video-level motion quality and temporal consistency. Overall, the proposed framework enables the generation of realistic multi-view echocardiographic sequences from diverse cardiac models, providing a scalable source of annotated data for dataset augmentation and the development of multi-view cardiac assessment methods.

0.33

MRI-Guided Reslice-Refined Cross-Slice SDF Reconstruction of the Left Ventricle from Cardiac MRI with Sparse Axial Supervision

cs.CV ·2026-09-08 ·Quanxin Zheng, Shuai Zhao
code/data similarity 0.65
Abstract

Reconstructing a three-dimensional left-ventricular (LV) endocardial surface from cardiac magnetic resonance (CMR) data is challenging when supervision is available on only a small number of axial slices. Through-plane geometry is weakly constrained, and automatically generated two-dimensional masks can propagate segmentation errors into the recovered shape. We present MR-RS-SDFR, a per-case implicit signed distance field (SDF) framework that reconstructs a continuous LV surface from a CMR volume and sparse axial weak masks. The method first builds a cross-slice SDF initialization from axial and longitudinal geometric cues and then refines the field using two complementary signals: MRI edge-field normal alignment, which provides an image-derived boundary cue independent of the weak masks, and differentiable reslice Dice and contour consistency, which preserve agreement with the observed planes. We evaluate three weak-mask generators -- LOO TransUNet, LOO nnU-Net, and an off-the-shelf Medical SAM3 model used without MM-WHS-specific training or fine-tuning -- and five sparsity levels from 4 to 64 axial planes. In the sparse-16 setting, final MR-RS-SDFR reconstruction reaches 0.928 Dice and 3.80mm HD95 with Medical SAM3 masks. The upstream generators do not exhibit a single common ranking across 2D and dense 3D segmentation, and nnU-Net- and Medical-SAM3-driven sparse reconstruction achieve the same mean final Dice despite different upstream error profiles. Across all three sparse-16 mask sources, MR-RS-SDFR is numerically better than protocol-matched full GHD+DVS in both Dice and HD95. Final Dice improves markedly from sparse-4 to sparse-16 and then saturates at the reported precision through sparse-64. These results support MRI-guided per-case SDF refinement as a reconstruction strategy that remains effective across weak-mask generators and supervision densities.

0.24