CS Paper Radar

Multi-Stage NeRF for Efficient 3D Coronary Artery Reconstruction from Two Narrow-Angle Angiographic Projections

Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee

cs.CG cs.CV ·submitted 2026-09-14 13:34 UTC · v1
top venue

Abstract

X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learning-based 2D-to-3D reconstruction methods typically require wide angular coverage or multiple views, assumptions that are rarely satisfied in routine practice where only two projections with narrow angular separation are available. To address these challenges, we propose NeCA++, a multi-stage self-supervised neural radiance field (NeRF) framework tailored to clinically realistic acquisition constraints. The framework decomposes reconstruction into two stages that progressively refine spatial support and representation capacity. In the first stage, a coarse 3D representation of the vasculature is reconstructed, restricting the subsequent optimisation to regions with a higher likelihood of vessel presence, termed an active region. Afterward reconstruction is restricted to this region while higher-resolution representations are progressively activated to recover fine vascular details. This multi-stage strategy focuses learning on anatomically plausible regions, mitigates gradient dilution under extreme sparsity, and stabilises global topology before recovering fine vascular branches. Furthermore, two vessel-specific regularisations are introduced: a ray-aligned constraint to reduce projection-induced ambiguity, and a bimodal density penalty to enable early vessel-background separation. Extensive experiments across three datasets (ImageCAS, ASOCA, and Synthetic RCA) and four angular configurations demonstrate consistent superiority over state-of-the-art baselines, particularly under clinically realistic narrow-angle settings, while achieving reconstruction within 58 seconds per case.

Comment
11 pages, 2 figures

Closest papers

Nearest neighbours by meaning across the whole index.

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

cs.CV ·2026-10-07 ·Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
code/data similarity 0.74
Abstract · 22 pages, 5 figures, 10 tables, including references and appendix. Code and pretrained models: https://github.com/G2304138H/PPCAR-Net . Proj…

Sparse-view 3D coronary reconstruction commonly relies on cross-view correspondence and triangulation, which are vulnerable to vessel overlap and foreshortening, or on volumetric prediction followed by vascular-graph extraction, which does not directly provide centrelines and radii. We introduce PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that directly predicts a branch-structured centreline-and-radius representation without explicit point matching, triangulation, or an intermediate volume. Given a variable number of segmented views, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch presence, B-spline centreline trajectories, and dense radius profiles. Projection-guided geometry and radius refiners then sample local evidence from the input views and apply residual corrections learned with 3D supervision. We evaluate representation fidelity and sparse-view reconstruction quantitatively and qualitatively. On simulated angiographic masks generated from CT-derived coronary anatomy, PPCAR-Net produces better connected artery reconstructions and achieves strong centreline accuracy, particularly for RCA, while maintaining competitive volumetric overlap. Coarse-to-fine inference takes 121 ms, enabling real-time reconstruction.

0.29

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.73
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

Anatomy-Aligned Surface Field Learning for Myocardial Reconstruction from Sparse Short-Axis Cine MRI

cs.CV ·2026-09-24 ·Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
code/data similarity 0.71
Abstract · 12

Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis (SAX) cine MRI is sparsely sampled along the through-plane direction, making dense and anatomically consistent surface reconstruction challenging. In this study, we propose an anatomy-aligned surface learning framework that parameterizes the epicardial and endocardial surfaces on a shared circumferential-longitudinal UV domain. This formulation converts irregular 3D reconstruction into structured coordinate-field completion with explicit correspondence across subjects and cardiac phases. Sparse SAX contours are encoded as UV observation fields, coverage-aware sampling improves robustness to incomplete slice coverage, and topology- and distortion-aware learning preserves circumferential continuity and local surface quality. Experiments on three public cine MRI datasets showed that the proposed method consistently outperformed representative mesh-based and implicit reconstruction approaches, achieving overall Chamfer distances of $2.887$~mm on ACDC, $2.641$~mm on M\&Ms, and $2.810$~mm on M\&Ms-2. The reconstructed sequences also preserved ventricular function, with end-diastolic volume and ejection fraction errors of $3.3$~mL and $1.1 \%$, respectively. These results demonstrate that anatomy-aligned UV learning provides an accurate, efficient, and correspondence-aware representation for sparse cine MRI reconstruction and myocardial modeling. The source code will be available at https://github.com/yuan-xiaohan/SAX2MyoSurf.

0.23

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.69
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

eess.IV cs.CV ·2026-11-03 ·Tianyuan Wang, Kenan Niu, Stefano Stramigioli
similarity 0.68
Abstract · 10 pages, 5 figures, 2 tables

Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

0.12

Temporal Diffusion Bridge Model for Vessel Extraction Using Physics-informed Synthetic Data

eess.IV cs.CV ·2026-10-08 ·Jinkui Hao, Donald R. Cantrell, Ramez Abdalla, Sameer A. Ansari, Bo Zhou
code/data similarity 0.68
Abstract · 13 pages, 6 figures. Under review at Medical Image Analysis

Accurate artery extraction from X-ray coronary angiography (XCA) is essential for coronary artery disease diagnosis and intervention. However, low vessel visibility, respiratory and cardiac motion, and limited annotations challenge existing methods. Moreover, most deep learning approaches produce binary vessel masks without preserving clinically relevant intra-arterial contrast information. We propose a Temporal Diffusion Bridge Model (TDBM) that formulates vessel extraction as image translation and learns from physics-informed synthetic data without manual vessel annotations. A physics-based XCA synthesis engine generates diverse, perfectly aligned pairs of contrast-enhanced and contrast-free images. Using these pairs, TDBM learns cross-domain mappings to recover high-fidelity vessel information. Temporal conditioning incorporates adjacent frames to improve consistency, while a vessel-aware contrastive loss exploits background-invariant synthetic pairs to enhance vascular discrimination. We evaluate TDBM on two XCA vessel segmentation datasets and conduct a reader study using two real-patient XCA sequence datasets. Zero-shot segmentation is further assessed on retinal imaging and fluorescence microscopy datasets. Results demonstrate that TDBM consistently outperforms existing methods and generalizes effectively across imaging modalities. Code and trained weights will be available at: https://github.com/Advanced-AI-in-Medicine-and-Physics-Lab/TDBM

0.21

Sub-Voxel Displacement and Ipsilateral Territory Decoupling for 3D Bilateral Coronary Artery Tree Reconstruction in Cardiac CT Angiography

cs.CV q-bio.TO ·2026-10-05 ·Zeyu Jia, Xin Ming
similarity 0.67
Abstract · 18 pages, 4 figures, 7 tables; includes combined Supplementary Material (Algorithms A1-A5 and Tables S1-S5)

Reconstructing topologically complete, sub-voxel-accurate 3D bilateral coronary artery trees from cardiac CT angiography (CCTA) requires simultaneously recovering continuous centerline trajectories and separating dense left/right coronary territories without cross-ostial collisions. We present a five-stage tubular drift and ipsilateral territory decoupling framework (M1-M5). Stage M1 pairs a 398,843-parameter multi-scale 3D pyramid encoder with a four-head tubular field network predicting vesselness probability, signed tubular boundary distance, unit tangent vectors, and continuous 3D centripetal displacement vectors. Stage M2 introduces recall-preserving multi-task optimization with 7-group AdamW parameter decoupling, L2-SP backbone regularization, and per-step anchor shrinkage. Stage M3 calibrates cylindrical Valsalva-sinotubular-junction wall coordinates and native-resolution orifice contact expectations for robust left and right ostial rooting. Stage M4 constructs a scalar-potential-weighted minimum-cost arborescence followed by normal-plane cross-sectional pullback and centripetal trajectory pruning. Stage M5 enforces coverage-guarded ipsilateral-field-coupled bilateral collision reduction and subtree handover. Across a 14-case held-out development cohort (Dev-14, 17-arm forward incremental build and 9-arm leave-one-out ablation) and an independent 50-case out-of-sample evaluation cohort (OOS-50) benchmarked against seven external architectures (nnU-Net, 3D UX-Net, Swin-UNETR, MedNeXt, CS2-Net, clDice-UNet, and Point-UNet), M1-M5 reduces bilateral chamfer distance on Dev-14 from 3.4381 mm to 2.2759 mm and achieves 2.7671 mm on OOS-50 with 7.11% bilateral collision rate and 79.7% distal branch completeness.

0.29

Pix2Rep-v2: Data-Efficient Representation Learning for Dense Medical Imaging Applications

cs.CV ·2026-09-01 ·S. Sifaoui, E. Angelini, S. Toupin, T. Pezel, L. Le Folgoc
top venuecode/data similarity 0.67
Abstract · Accepted at MICCAI 2026

Dense self-supervised learning (SSL) is a powerful paradigm for learning without annotations the local descriptors required to solve dense medical imaging tasks. We present Pix2Rep-v2, a framework for SSL of pixel- and voxel-level representations suitable for few-shot downstream applications. Pix2Rep-v2 addresses the main challenges of dense SSL by leveraging a redundancy reduction objective at the pixel-level with a principle of equivariance of dense representations, that scales efficiently to 3D or wide field-of-view applications. We evaluate our method on four datasets, across multiple tasks, multiple modalities and anatomical structures using multiple backbones in 2D and 3D, and under various data regimes. As an alternative to linear probing or full fine-tuning on the downstream task, we also propose an in-context variant, without downstream training, based on a dense prototype approach. Pix2Rep-v2 shows substantially higher data-efficiency in few-shot scenarios compared to fully supervised baselines, and is competitive with the state-of-the-art e.g., +9.3 Dice points in one-shot segmentation on the M&Ms-2 dataset. Our code and pre-trained models are publicly available at https://github.com/BioMedTP/pix2rep-v2.

0.77