CS Paper Radar

Label-Preserving Fourier Domain Adaptation with Generative-AI and Real Style Donors for 3D Mitral Valve Segmentation

Javeria Javed, Ahmed Salim, Muhammad Mahboob Ur Rahman

eess.IV cs.CV ·submitted 2026-11-03 16:01 UTC · v1

Abstract

Accurate segmentation of the mitral valve from three-dimensional transesophageal echocardiography (3D TEE) is severely restricted by the scarcity of publicly available expert- annotated volumetric datasets. To address this critical limitation, we investigated Fourier Domain Adaptation (FDA), utilizing general-purpose generative-AI images (from platforms like Chat- GPT, Google Gemini, and Microsoft MAI) as annotation-free style donors for 3D mitral valve segmentation. We employed a DeepMitral residual U-Net model on the public MVSeg2023 dataset, comparing six conditions over three runs: real-only training, traditional augmentation, FDA with each generative source, and a non-AI FDA control using real-image style donors, plus an optimization-matched real-only control and a \b{eta} sensitivity analysis. Case-level paired testing showed that FDA with these generative sources led to significant reductions in boundary- and surface-related errors across all three donor conditions relative to the primary real-only baseline. However, the impact on the core segmentation metric, Generalized Dice Score (GDS), proved generator-dependent. ChatGPT-FDA showed a significant GDS advantage over the optimization-matched control but not over the primary baseline, and Gemini-FDA showed no significant GDS difference. Notably, only MAI-FDA provided a statistically robust and significant increase in GDS compared to the primary baseline. The \b{eta} sensitivity was not robust across training runs. These findings confirm that FDA remains an important augmentation mechanism. While generative-AI images offer a practical means of acquiring style diversity without new annotations, the non-AI control performed comparably to ChatGPT-FDA, so we do not conclude that this approach is superior to training with real-image donors.

Comment
7 pages, 1 figure, 3 tables, submitted to IEEE for possible publication

Closest papers

Nearest neighbours by meaning across the whole index.

LISynSeg: Data-Centric Label-to-Image Synthesis for Cross-Modality Whole-Heart Segmentation

cs.CV eess.IV ·2026-08-31 ·Jiacheng Wang, Ivana Isgum, Ipek Oguz
benchmarkcode/data similarity 0.69
Abstract · 12 pages, 4 figures

Whole-heart segmentation (WHS) in computed tomography (CT) and magnetic resonance imaging (MRI) is affected by acquisition shifts and heterogeneous cardiac annotations. Existing WHS systems combine architectural design, transfer learning, and generic spatial or intensity augmentation. We investigate whether changes to data augmentation and training supervision can improve cross-modality WHS while the segmentation architecture is held constant. We present LISynSeg, a data-centric approach that augments real-image nnU-Net training with label-to-image synthesis. Synthetic volumes are generated from cardiac label maps using contrast and acquisition perturbations calibrated to the training cohort, then mixed with real images to retain thoracic context absent from the labels (and thus the synthesized images). We model cardiac label variation through controlled changes in myocardial wall thickness and partial supervision of uncertain vessel endpoints. On the CARE Whole-Heart benchmark, synthetic-only training performs worse than the real-image nnU-Net baseline, whereas calibrated real-synthetic training improves cross-modality segmentation without changing the architecture; the improvement is larger for MRI than for CT. The results show that modifying the training data strategy can benefit model development for heterogeneous cardiac data. Code and trained weights will be released at https://github.com/MedICL-VU/Care26_LISynSeg.

0.38

SymmAdapt: Symmetrical Flow Matching for Source-Free Domain Adaptation in Medical Image Segmentation

cs.CV ·2026-08-23 ·Tal Grossman, Noa Cahan, Hayit Greenspan
published similarity 0.67
Abstract · Accepted at SASHIMI 2026, held in conjunction with MICCAI 2026. To appear in the Springer LNCS proceedings of the MICCAI 2026 Satellite Even…

Domain shift across imaging modalities and acquisition sites remains a significant barrier to the clinical deployment of segmentation models. Source-free unsupervised domain adaptation (SFUDA) addresses this by adapting a pretrained model to an unlabeled target domain without requiring access to sensitive source data. We introduce a novel SFUDA framework built on Symmetrical Flow Matching, a unified generative model that segments an input image and synthesizes a source-like image from a mask within the same learned flow. By initializing inference from a domain-agnostic Gaussian origin, the model preserves structural consistency across domains and grounds predictions in learned anatomy rather than shifted texture statistics. Our pipeline leverages this symmetry to generate reliable pseudo-labels and corresponding source-like synthetic images from unlabeled target data, creating a generative replay buffer that anchors source knowledge during a generative self-training stage that fine-tunes on a joint set of real target and synthetic source-like images. We evaluate on abdominal multi-organ and cardiac segmentation, covering cross-modality MRI<->CT shifts, and multi-site prostate segmentation. Our approach outperforms SFUDA baselines and is competitive with conventional UDA methods.

0.25

Beyond In-Distribution Metrics: A Systematic Out-of-Distribution Evaluation of Congenital Heart Disease Segmentation

cs.CV cs.AI ·2026-09-15 ·Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya +3 more
published similarity 0.66
Abstract · 12 pages, 6 figures, 2 tables. Accepted at STACOM 2026, held in conjunction with MICCAI 2026

Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Although deep-learning methods can automate this process, they are typically evaluated in-distribution, despite clinically relevant shifts in scanner, protocol, institution, population, and imaging modality. We present, to our knowledge, the first systematic evaluation of out-of-distribution (OOD) generalization in CHD segmentation, using ImageCHD as a held-out target cohort. We compare representative segmentation architectures under combined CT and CMR training, CT-only training, self-supervised pretraining, and limited target-domain adaptation. In-distribution performance proves to be a poor indicator of cross-cohort robustness: nnU-Net achieves the highest validation Dice (0.77) but falls to 0.51 on ImageCHD, while SwinUNETR generalizes substantially better, reaching 0.67 Dice. MAE and JEPA pretraining provide only modest additional benefit, suggesting that architecture contributes more to robustness than the tested pretraining strategies in this setting. When limited target-domain supervision is introduced, all SwinUNETR variants exceed 0.76 Dice with only 11 labeled ImageCHD cases. These findings demonstrate that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation.

0.28

Dual Co-Train: Cross-Dataset Ultrasound Tongue Segmentation Under Extreme Data Scarcity

cs.CV cs.AI ·2026-08-18 ·Alisher Myrgyyassov, Zhen Song, Bruce Xiao Wang, Yu Sun, Min Ney Wong +2 more
similarity 0.65
Abstract

Ultrasound tongue contour segmentation remains challenging under cross-dataset domain shift, where limited annotations, probe variability, and acquisition noise often degrade model generalization. We present a source-free domain adaptation framework for robust ultrasound tongue segmentation built on a lightweight UltraUNet backbone. Starting from a checkpoint pretrained on only five labeled source images, simulating an underfitted constrained source model, the proposed method adapts to a fully-unlabeled target domain by iteratively refining pseudo-labels, filtering unreliable masks with a contour-based quality-control module, and generating target-style synthetic image-mask pairs through a segmentation-guided conditional GAN. The student model is then trained on a mixture of clean pseudo-labeled target images, noisy pseudo-labels with consistency regularization, and synthetic samples, enabling closed-loop adaptation without access to source data. We evaluate the method on 12 source-target transfer pairs across eight ultrasound tongue imaging datasets, and conduct source-size scaling experiments and ablation studies. Across all comparisons, the proposed framework improves segmentation overlap and contour accuracy over the baselines, including supervised ones. These results suggest that task-specific pseudo-label refinement and synthetic target-style augmentation can substantially improve source-free adaptation for ultrasound tongue imaging.

0.21

Improving Cross-Site Whole-Heart Segmentation

eess.IV cs.CV ·2026-08-25 ·Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao +2 more
publishedcode/data similarity 0.65
Abstract · 12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

0.51

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.63
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

Unsupervised Adaptation of 3D CT Foundation Models for 3D CBCT Segmentation

cs.CV ·2026-08-27 ·Gauthier Miralles, Loic Le Folgoc, Vincent Jugnon, Pietro Gori
publishedcode/data similarity 0.62
Abstract · Accepted at the EMA4MICCAI workshop at MICCAI 2026. 11 pages, 4 figures, 1 table. Code, trained models, weights, and liver annotations are a…

Accurate 3D segmentation of cone-beam CT (CBCT) is critical for interventional and radiation therapy applications, yet it remains limited by two compounding challenges: the scarcity of annotated CBCT data and the large domain shift from diagnostic CT. Interventional CBCT exhibits fundamental modality differences from conventional CT, driven by acquisition and physics effects as well as contrast-specific vascular content, thereby limiting effective cross-modality model transfer. We propose a novel unsupervised domain adaptation (UDA) framework based on redundancy-reducing feature alignment, enabling 3D CBCT segmentation with no target-domain annotations or inference-time adaptation. Our framework is architecture-agnostic, seamlessly adapting both CNN-based and ViT-based foundation models. We evaluate our method on two challenging CT-CBCT liver segmentation benchmarks: one for interventional vascular procedures and one for radiation therapy, demonstrating that even large-scale pretrained segmentation networks require explicit feature-space bridging to generalize across acquisition modalities, and that our approach consistently outperforms existing pretrained foundation model and UDA strategies. To support reproducibility and benchmarking, we release the liver segmentations for a public CBCT dataset, along with the code, trained models, and weights.

0.41

Thyroid Nodule Segmentation in Ultrasound Images with Conformal Uncertainty Estimation

cs.CV stat.AP ·2026-10-09 ·Francesco Teodori, Pierpaolo Brutti, Umberto Ferraro Petrillo
publishedbenchmark similarity 0.62
Abstract · Presented at the CIBB 2026 conference

Thyroid nodules affect a large proportion of the general population. Although most are benign, a non-negligible fraction is malignant. Ultrasound imaging is the primary diagnostic modality, and accurate nodule segmentation is a prerequisite for CAD systems to classify malignancy and assess metastatic risk.\\ In this work, we propose a thyroid nodule segmentation framework that integrates a DeepLabV3+, channel-attention modules and post-hoc conformal prediction, providing both accurate mask and pixel-level uncertainty estimates. We address thyroid ultrasound nodule segmentation as the first stage of a pipeline that also includes malignancy classification and metastatic risk prediction. We adopt DeepLabV3+, whose Atrous Spatial Pyramid Pooling (ASPP) captures multi-scale context, with an EfficientNet-B5 backbone for its accuracy-efficiency trade-off. Additionally, we test three channel-attention modules: Squeeze-and-Excitation, CBAM and Grouped Channel Attention (GCA), paired with two loss formulations (Dice-BCE and Boundary).\\ Since binary masks do not indicate prediction confidence, we wrap the trained model with a split conformal prediction layer that produces pixel-level uncertainty maps with statistical coverage guarantees.\\ We evaluate all configurations on the TN3K public benchmark using a fixed split and directly compare them with state-of-the-art methods. The plain backbone already improves upon previously reported results, with CBAM + Dice-BCE emerging as the best overall configuration.

0.17