CS Paper Radar

ConPro: Contrast Projection Pretraining for Label-Efficient Vessel Segmentation in DSA Sequences

Xinge Guo, Yuanhao Wang, Liqi Shu, Yang Liu, Min Xu

cs.CV ·submitted 2026-09-24 16:09 UTC · v1

Abstract

Dense vessel annotation in digital subtraction angiography (DSA) is labor-intensive, yet every unlabeled sequence records how contrast passes through the vessels. Semi-supervised methods take their targets from the current model, and generic self-supervised pretexts reconstruct static appearance, so this signal goes unused. We propose ConPro, a self-supervised pretraining scheme whose target is a contrast projection, the normalized drop of every pixel below its temporal median over the sequence. On DIAS and DSCA, with 10%, 20% and 50% of the training cases labeled, ConPro improves on training from scratch at every label fraction and is the best of the compared methods on DSCA at 20% and 50% labels. Controlled comparisons show that the gain comes from the target. A temporal-median target with the same input, loss and budget stays at scratch level, and using the projection directly instead of learning it, as an input channel or a pseudo-label, helps little or hurts. ConPro provides pretrained weights without changing the segmentation architecture, so it combines with semi-supervised training, and UniMatch, the strongest baseline, gains 0.5 to 2.0 Dice and 0.9 to 2.3 clDice at every label fraction when started from ConPro weights, reaching 75.4 Dice on DIAS and 81.3 on DSCA.

Comment
5 pages, 4 figures, 2 tables. Submitted to IEEE ICASSP 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Self-training for cross-centre coronary vessel segmentation in X-ray angiography using pre-contrast frame subtraction

cs.CV cs.AI ·2026-10-29 ·Danial Moafi, Aida Moafi, Mostafa Aryafar, Ashkan Sami, Maryam Aryafar
similarity 0.75
Abstract · 7 pages, 2 figures, 3 tables

Deep learning models for coronary vessel segmentation in X-ray angiography often perform poorly on data from centres that were not represented in training. Apart from differences in equipment, the labels of the largest public dataset (ARCADE) are incomplete, as only the segments defined in the SYNTAX score are annotated. In this study, we evaluated whether self-training with pseudo-labels can improve performance on external data without additional manual annotation. Pseudo-labels were generated from two sources, namely the predictions of an nnU-Net model trained on ARCADE and a contrast map obtained by subtracting a pre-contrast frame from the same sequence. The nnU-Net predictions were extended along the contrast map, and pixels detected only in the subtraction image were assigned an ignore label and excluded from the loss. Six models were trained and tested on ARCADE and on two external datasets (XCAD and XACV). All first-round models initialised with the baseline predictions performed better than both the baseline and a control model fine-tuned for the same number of epochs. The model trained on the XCAD pool improved the macro-averaged Dice score by 2.7 points (95% CI 2.3-3.2), while the control decreased it by 0.6 points. A second round of self-training did not lead to further improvement. When an external model trained on 50 fully annotated images was used to generate the initial labels, the XCAD Dice score increased from 0.623 to 0.745 without any XCAD labels, although performance on XACV did not improve because large main vessels were missed. These results suggest that the benefit of self-training depends largely on the sensitivity of the model used to generate the initial pseudo-labels.

0.18

Temporal Diffusion Bridge Model for Vessel Extraction Using Physics-informed Synthetic Data

eess.IV cs.CV ·2026-10-08 ·Jinkui Hao, Donald R. Cantrell, Ramez Abdalla, Sameer A. Ansari, Bo Zhou
code/data similarity 0.67
Abstract · 13 pages, 6 figures. Under review at Medical Image Analysis

Accurate artery extraction from X-ray coronary angiography (XCA) is essential for coronary artery disease diagnosis and intervention. However, low vessel visibility, respiratory and cardiac motion, and limited annotations challenge existing methods. Moreover, most deep learning approaches produce binary vessel masks without preserving clinically relevant intra-arterial contrast information. We propose a Temporal Diffusion Bridge Model (TDBM) that formulates vessel extraction as image translation and learns from physics-informed synthetic data without manual vessel annotations. A physics-based XCA synthesis engine generates diverse, perfectly aligned pairs of contrast-enhanced and contrast-free images. Using these pairs, TDBM learns cross-domain mappings to recover high-fidelity vessel information. Temporal conditioning incorporates adjacent frames to improve consistency, while a vessel-aware contrastive loss exploits background-invariant synthetic pairs to enhance vascular discrimination. We evaluate TDBM on two XCA vessel segmentation datasets and conduct a reader study using two real-patient XCA sequence datasets. Zero-shot segmentation is further assessed on retinal imaging and fluorescence microscopy datasets. Results demonstrate that TDBM consistently outperforms existing methods and generalizes effectively across imaging modalities. Code and trained weights will be available at: https://github.com/Advanced-AI-in-Medicine-and-Physics-Lab/TDBM

0.21

Synthetic training for long-tail haemorrhagic lesion segmentation in data-scarce settings

cs.CV ·2026-10-01 ·Yuan Cao, Sumeet Dash, Antonia Zachariadis, Stefanie Schreiber, Katja Neumann +1 more
published similarity 0.64
Abstract · Accepted: MICCAI 2026 SASHIMI workshop

Cerebral microbleeds (CMBs) and cortical superficial siderosis (cSS) are imaging markers of cerebral small vessel disease, but their automated segmentation is limited by the scarcity of positive cases and voxel-level annotations. We propose a synthetic training framework for long-tail haemorrhagic lesion segmentation that requires no real lesion annotations for training and leverages radiological description of the lesions. Starting from anatomical brain parcellations, the framework applies spatial augmentation and voxel resampling, procedurally inserts cSS and CMB labels using clinical priors on lesion location and morphology, and synthesises images through randomised intensity assignment, blurring, and Rician noise simulation. Models were trained on dynamically generated image-label pairs and evaluated against manual delineations in 10 cSS cases and 13 CMB cases. The proposed configurations outperformed classical filter baselines. For cSS, the hypointensity constrained model achieved higher AUPRC and AUROC than the Frangi filter (AUPRC: 0.284 vs 0.083; AUROC: 0.907 vs 0.731). For CMBs, explicit synthesis of blood vessels as lesion mimics improved performance over the classical baseline (AUPRC: 0.538 vs 0.004; AUROC: 0.999 vs 0.968). These results support our proposal as a feasible strategy for data-scarce haemorrhagic lesion segmentation.

0.39

Scribble Once, Segment the Sequence: Bidirectional Temporal Consistency for Weakly Supervised Segmentation in Echocardiography Sequences

eess.IV cs.CV ·2026-11-16 ·Vincent Li Weixin, Chen Jingkun, Vicente Grau
similarity 0.63
Abstract

Temporal medical image segmentation relies on pixel-wise annotations, which are prohibitively expensive for long image sequences. Existing weakly-supervised methods reduce the annotation burden per frame but still require repeated annotations across the sequence. Furthermore, sparse supervision can result in temporally unstable representations. Addressing both challenges requires a model that can leverage strong spatial priors from large-scale pretraining while minimizing reliance on dense annotations. Frozen 2D vision foundation models provide a promising basis for this by offering transferable spatial representations with low trainable parameters. However, their lack of explicit temporal modeling limits their ability to propagate reliable information across anatomical sequences. To address this, we present a weakly-supervised framework for temporal segmentation from a single scribble-annotated frame, with all remaining frames left unlabeled. The framework combines parameter-efficient adaptation of DINOv3 encoders present in the mean-teacher architecture. Furthermore, a set of complementary losses, including a temporal loss helps generate reliable segmentation priors for the unlabeled frames. This formulation decouples annotation costs from sequence length while retaining the transferable spatial knowledge of the pretrained encoder. Extensive experiments on the publicly available CAMUS and CardiacNet datasets demonstrate that our approach outperforms other scribble-supervised methods. These results show that accurate and temporally consistent segmentation can be achieved from extremely sparse supervision, substantially reducing annotation requirements for temporal echocardiographic segmentation and providing a practical framework for scalable clinical deployment.

0.16

TEMPL: A Resource-Efficient and Transparent Model-Free Framework for Pseudo-Label Generation in Material CT Scans

cs.CV ·2026-10-20 ·Ashiqur Rahman, Venkata Devesh Reddy Seethi, Austin Yunker, Rajkumar Kettimuthu, Hamed Alhoori
similarity 0.62
Abstract

The scarcity of large annotated datasets limits deep learning (DL) segmentation in material CT analysis. DL-based pseudo-labeling can help, but it is often computationally expensive and hard to interpret. We introduce a multi-stage, model-free framework that generates pseudo-labels directly from grayscale CT scans. It combines thresholding, morphological dilation, and a custom breadth-first search region-growing algorithm to produce polygonal annotations without pre-trained weights, labeled data, or a GPU. We compare it against the zero-shot Segment Anything Model (SAM), a fully supervised 3D U-Net, and classical baselines. On a dendrite dataset with ground truth, our method reaches 63.19% IoU versus 10.74% for zero-shot SAM, with four times the instance recall at 0.5 IoU (33.3% versus 8.3%). The supervised 3D U-Net serves as a reference ceiling that requires expert labels. On a silica sand specimen, YOLO models trained on our labels performed comparably to models trained on SAM labels in a qualitative comparison. Across 1,053 extracted grains, the median equivalent diameter was 163.8 micrometers, near the specimen's known 106 to 150 micrometers sieve range, compared with 219.5 micrometers for SAM, whose labels merge adjacent particles and add spurious detections. A sensitivity analysis shows a stable operating range for the key threshold and a sharp, predictable failure point linked to phase contrast. Our method needs 15s per image on a standard CPU versus 28s for SAM on a GPU. These results support our transparent approach as a tool for annotation bootstrapping and microstructural quantification in resource-limited settings.

0.13

DART: Depth-as-Target Pretraining for Surgical Vision Foundation Models

cs.CV ·2026-09-03 ·John J. Han, Adam Schmidt, Muhammad Abdullah Jamal, Jie Ying Wu, Omid Mohareri
published similarity 0.62
Abstract · Accepted to BMVC 2026

Vision foundation models (VFMs) are valuable in data-scarce domains such as surgery, where a single pretrained backbone can provide rich representations for many downstream tasks. Yet the dominant self-supervised pretraining paradigm uses only RGB images, leaving readily available complementary signals, such as depth maps, unused. This is a particular missed opportunity in surgery, where natural-image VFMs transfer poorly while the scene geometry is rich and informative. With strong off-the-shelf models now able to produce pseudo-labeled dense depth for any image corpus, we hypothesize that such signals can be folded into pretraining to learn better representations. We present DART, an RGB-D pretraining recipe that builds on DINOv2 with a simple modification: a pixel-space depth reconstruction objective applied to masked iBOT patches, supervised by pseudo-labeled depth. Depth is used only during pretraining, so fine-tuning and inference remain RGB-only. We find that this pixel-level reconstruction head improves representation quality rather than disrupting it. We further show that depth, which encodes scene geometry, is more effective as a target than alternative dense signals such as Canny edges, confirming that the gains stem from depth rather than added supervision alone. Across eight surgical benchmarks spanning segmentation, depth estimation, and image-level recognition, DART outperforms both natural-image and in-domain baselines, including a vanilla DINOv2 trained on identical data, improving dense prediction while also strengthening image-level understanding. More broadly, DART shows that freely available geometric pseudo-labels can strengthen foundation model pretraining without extra labels or added inference cost, pointing toward stronger backbones for surgery.

0.38

Less Is More in the Long Tail: Stage-Adaptive Sample Selection for Annotation-Efficient Dense Prediction

cs.CV ·2026-09-22 ·Xiaofei Du, Lei Zhang, Shuyu Yan, Manning Wang, Zhijian Song
similarity 0.62
Abstract

Deep learning performance generally improves with increasing training data, yet this scaling is fundamentally constrained by annotation cost in large-scale dense prediction tasks with long-tailed category distributions, where pixel- or voxel-level annotation is prohibitively expensive. We propose SASS (Stage-Adaptive Sample Selection), a stage-adaptive data-selection framework for pool-based active learning in long-tailed dense prediction. SASS combines three components: label-free self-supervised gradient scoring, prior-guided category rebalancing with validation-driven feedback, and stage-adaptive acquisition aligned with model training dynamics. This design avoids candidate ground-truth masks during gradient scoring while making acquisition responsive to long-tail imbalance and evolving representations. We evaluate SASS on a multimodal 3D medical segmentation testbed comprising over 100,000 samples spanning 108 anatomical structures. SASS recovers 98.3% of full-dataset performance with a 40% training-pool annotation budget, outperforming BADGE by 5.1 percentage points. Moreover, SASS exhibits a statistically supported less-is-more pattern, surpassing full-dataset training at the Hard-group level and, at the structure level, for the pancreas and gallbladder. More broadly, SASS shows that annotation-efficient learning depends not only on which samples are selected, but also on how the annotation budget is distributed across categories and when model-derived scores begin to guide selection.

0.18

VeCAS: Vessel-Focused Contrast-Free Angiogram Synthesis for Vascular Interventions

cs.CV ·2026-08-24 ·De-Xing Huang, Chen-Yu Wang, Hao Liang, Xiao-Hu Zhou, Mei-Jiang Gui +8 more
hot direction similarity 0.61
Abstract · 10 pages, 8 figures, 5 tabels, supplementary material: https://dxhuang-casia.github.io/data/vecas_supplementary_material.pdf

X-ray angiography relies on iodinated contrast agents to visualize vascular structures during image-guided interventions. However, contrast administration carries risks of adverse events, motivating the development of contrast-free alternatives. Generating X-ray angiograms directly from non-contrast X-ray images offers a potential solution, but existing approaches remain limited by (i) insufficient control over vascular localization and (ii) inefficient modeling of redundant background content. To address these challenges, we propose VeCAS, a two-stage vessel-focused contrast-free angiogram synthesis framework that separates vascular structure localization from angiographic appearance synthesis. In Stage I, a discriminative model localizes vascular structures in non-contrast X-ray images, while cross-modality latent distillation transfers vessel-sensitive knowledge from X-ray angiograms during training. In Stage II, a vessel-focused inpainting model synthesizes angiographic appearance within the localized vascular regions while preserving the non-vascular background. Experiments on an in-house lower-limb vascular intervention dataset show that VeCAS outperforms the comparison methods in terms of vascular structural fidelity and image quality. Visual Turing tests and physician assessments indicate the perceptual realism of the synthesized angiograms. In addition, robotic guidewire navigation experiments in vascular phantoms show that VeCAS guidance reduces the time to target by 41.4% and the number of operation steps by 40.7% compared with non-contrast guidance. Together, these results suggest the potential of VeCAS to serve as ``meta contrast agent'' for vascular interventions.

0.49