CS Paper Radar

VeCAS: Vessel-Focused Contrast-Free Angiogram Synthesis for Vascular Interventions

De-Xing Huang, Chen-Yu Wang, Hao Liang, Xiao-Hu Zhou, Mei-Jiang Gui, Tian-Yu Xiang, Qin-Yi Zhang, Chen Wang, Xiao-Liang Xie, Shi-Qi Liu, Ming-Yuan Liu, Zhen-Chang Wang, Zeng-Guang Hou

cs.CV ·submitted 2026-08-24 05:43 UTC · v1
hot direction

Abstract

X-ray angiography relies on iodinated contrast agents to visualize vascular structures during image-guided interventions. However, contrast administration carries risks of adverse events, motivating the development of contrast-free alternatives. Generating X-ray angiograms directly from non-contrast X-ray images offers a potential solution, but existing approaches remain limited by (i) insufficient control over vascular localization and (ii) inefficient modeling of redundant background content. To address these challenges, we propose VeCAS, a two-stage vessel-focused contrast-free angiogram synthesis framework that separates vascular structure localization from angiographic appearance synthesis. In Stage I, a discriminative model localizes vascular structures in non-contrast X-ray images, while cross-modality latent distillation transfers vessel-sensitive knowledge from X-ray angiograms during training. In Stage II, a vessel-focused inpainting model synthesizes angiographic appearance within the localized vascular regions while preserving the non-vascular background. Experiments on an in-house lower-limb vascular intervention dataset show that VeCAS outperforms the comparison methods in terms of vascular structural fidelity and image quality. Visual Turing tests and physician assessments indicate the perceptual realism of the synthesized angiograms. In addition, robotic guidewire navigation experiments in vascular phantoms show that VeCAS guidance reduces the time to target by 41.4% and the number of operation steps by 40.7% compared with non-contrast guidance. Together, these results suggest the potential of VeCAS to serve as ``meta contrast agent'' for vascular interventions.

Comment
10 pages, 8 figures, 5 tabels, supplementary material: https://dxhuang-casia.github.io/data/vecas_supplementary_material.pdf

Closest papers

Nearest neighbours by meaning across the whole index.

Temporal Diffusion Bridge Model for Vessel Extraction Using Physics-informed Synthetic Data

eess.IV cs.CV ·2026-10-08 ·Jinkui Hao, Donald R. Cantrell, Ramez Abdalla, Sameer A. Ansari, Bo Zhou
code/data similarity 0.70
Abstract · 13 pages, 6 figures. Under review at Medical Image Analysis

Accurate artery extraction from X-ray coronary angiography (XCA) is essential for coronary artery disease diagnosis and intervention. However, low vessel visibility, respiratory and cardiac motion, and limited annotations challenge existing methods. Moreover, most deep learning approaches produce binary vessel masks without preserving clinically relevant intra-arterial contrast information. We propose a Temporal Diffusion Bridge Model (TDBM) that formulates vessel extraction as image translation and learns from physics-informed synthetic data without manual vessel annotations. A physics-based XCA synthesis engine generates diverse, perfectly aligned pairs of contrast-enhanced and contrast-free images. Using these pairs, TDBM learns cross-domain mappings to recover high-fidelity vessel information. Temporal conditioning incorporates adjacent frames to improve consistency, while a vessel-aware contrastive loss exploits background-invariant synthetic pairs to enhance vascular discrimination. We evaluate TDBM on two XCA vessel segmentation datasets and conduct a reader study using two real-patient XCA sequence datasets. Zero-shot segmentation is further assessed on retinal imaging and fluorescence microscopy datasets. Results demonstrate that TDBM consistently outperforms existing methods and generalizes effectively across imaging modalities. Code and trained weights will be available at: https://github.com/Advanced-AI-in-Medicine-and-Physics-Lab/TDBM

0.21

BSC-Net: A Small-Branch-Sensitive Structural Continuity Network for Coronary Vessel Segmentation and Quantitative Angiographic Analysis

cs.CV ·2026-09-14 ·Wanxian Li, Jiaqian Qin, Qingyi Xian, Yazhi Li, Song Chen +2 more
similarity 0.64
Abstract · 29 pages, 9 figures, including Supplementary Material

Vessel segmentation in X-ray coronary angiography (XCA) is a fundamental step for quantitative coronary analysis and subsequent assessment of coronary artery disease. However, accurate vessel segmentation remains challenging because of imaging noise, complex bifurcations, and the overlap of vessels and background structures, which can lead to disrupted vascular connectivity and missed small branches. In this work, we propose BSC-Net, a ResNet-U-Net-based framework tailored to improve small-vessel representation and repair vascular structural continuity. BSC-Net enhances small-vessel representation through targeted sampling and improves vascular structural continuity by integrating long-range contextual modeling and Edge-Informed Loss (EIL). BSC-Net was validated on two public XCA datasets, demonstrating state-of-the-art (SOTA) performance in coronary vessel segmentation with Dice and IoU scores of 77.8%/90.6% and 64.5%/83.0%, respectively. Furthermore, based on the obtained vessel segmentation, we performed automated quantitative coronary analysis and derived clinically relevant morphological and hemodynamic parameters, including stenosis ratio, time-to-peak, and relative propagation velocity. These results demonstrate that BSC-Net produces accurate vessel segmentation results with preserved vascular continuity for quantitative coronary assessment, enabling reliable downstream analysis and clinical evaluation of coronary artery disease.

0.21

Self-training for cross-centre coronary vessel segmentation in X-ray angiography using pre-contrast frame subtraction

cs.CV cs.AI ·2026-10-29 ·Danial Moafi, Aida Moafi, Mostafa Aryafar, Ashkan Sami, Maryam Aryafar
similarity 0.62
Abstract · 7 pages, 2 figures, 3 tables

Deep learning models for coronary vessel segmentation in X-ray angiography often perform poorly on data from centres that were not represented in training. Apart from differences in equipment, the labels of the largest public dataset (ARCADE) are incomplete, as only the segments defined in the SYNTAX score are annotated. In this study, we evaluated whether self-training with pseudo-labels can improve performance on external data without additional manual annotation. Pseudo-labels were generated from two sources, namely the predictions of an nnU-Net model trained on ARCADE and a contrast map obtained by subtracting a pre-contrast frame from the same sequence. The nnU-Net predictions were extended along the contrast map, and pixels detected only in the subtraction image were assigned an ignore label and excluded from the loss. Six models were trained and tested on ARCADE and on two external datasets (XCAD and XACV). All first-round models initialised with the baseline predictions performed better than both the baseline and a control model fine-tuned for the same number of epochs. The model trained on the XCAD pool improved the macro-averaged Dice score by 2.7 points (95% CI 2.3-3.2), while the control decreased it by 0.6 points. A second round of self-training did not lead to further improvement. When an external model trained on 50 fully annotated images was used to generate the initial labels, the XCAD Dice score increased from 0.623 to 0.745 without any XCAD labels, although performance on XACV did not improve because large main vessels were missed. These results suggest that the benefit of self-training depends largely on the sensitivity of the model used to generate the initial pseudo-labels.

0.18

ReG-SAM: Reference Graph-Driven SAM for 2D Foundational Vessel Segmentation

cs.CV cs.AI ·2026-09-25 ·Donghang Lyu, Zichen Zhang, Oleh Dzyubachyk, Marius Staring
similarity 0.62
Abstract

Vessel segmentation in medical images is essential for many clinical tasks, ranging from diagnosis to treatment planning. However, it remains challenging due to complex vascular morphology and diverse imaging conditions. Existing deep learning methods rarely aim at building a generalizable vessel segmentor across anatomies and modalities. While the Seg- ment Anything Model (SAM) has shown promise for med- ical image segmentation, its original design does not fully exploit vascular morphology and struggles with fine-grained vascular structures, leading to suboptimal performance. In this paper, we propose ReG-SAM, a SAM-based framework tailored to 2D vessel segmentation that leverages reference graph set for enhancing vascular representations. Specifically, we introduce two modality-aware representations derived from the reference masks: graph prompt embeddings (GPEs) that encode global spatial features from graphs, and vascu- lar prototype embeddings (VPEs) that capture fine-grained modality-specific vessel characteristics from multi-scale fea- ture maps and vascular masks. Since both require vascular masks that are unavailable during inference and require robust modality-aware vascular feature representations, we construct a modality-wise vascular database and develop two reference graph-guided representation learning schemes for estimating GPEs and VPEs using samples from the database rather than ground-truth masks. Extensive experiments across 19 datasets demonstrate that ReG-SAM consistently outperforms existing baselines, even those using manual prompts, particularly on challenging thin vessels.

0.09

MoE-based Feature Adapter for Prompt-free Binary Coronary Artery Segmentation in X-ray Angiography

cs.CV ·2026-08-25 ·Lin Xi, Yingliang Ma
similarity 0.62
Abstract

Accurate segmentation of coronary arteries in X-ray angiography videos is essential for quantitative coronary analysis and image-guided interventions. However, accurate segmentation remains challenging because coronary vessels are thin and exhibit low contrast, while the presence of catheters, guidewires, and complex anatomical background structures can further interfere with vessel delineation. Existing U-Net- and Transformer-based models provide strong baselines, but their shared feature-adaptation pathways may be insufficient for heterogeneous angiographic appearances. In this paper, we propose a prompt-free mixture-of-experts (MoE) feature adapter for binary coronary artery segmentation. Built upon parameter-efficient Vision Transformer adapters, the proposed method uses multiple lightweight experts with input-dependent top-$k$ routing to adaptively refine vessel-related features while limiting active computational cost. Experiments on MOSXAV and external evaluation on XACV show that the proposed method outperforms representative baselines and improves cross-dataset generalisation. These results suggest that MoE-based adapter learning is effective for robust coronary artery segmentation in X-ray angiography videos.

0.26

ConPro: Contrast Projection Pretraining for Label-Efficient Vessel Segmentation in DSA Sequences

cs.CV ·2026-09-24 ·Xinge Guo, Yuanhao Wang, Liqi Shu, Yang Liu, Min Xu
similarity 0.61
Abstract · 5 pages, 4 figures, 2 tables. Submitted to IEEE ICASSP 2027

Dense vessel annotation in digital subtraction angiography (DSA) is labor-intensive, yet every unlabeled sequence records how contrast passes through the vessels. Semi-supervised methods take their targets from the current model, and generic self-supervised pretexts reconstruct static appearance, so this signal goes unused. We propose ConPro, a self-supervised pretraining scheme whose target is a contrast projection, the normalized drop of every pixel below its temporal median over the sequence. On DIAS and DSCA, with 10%, 20% and 50% of the training cases labeled, ConPro improves on training from scratch at every label fraction and is the best of the compared methods on DSCA at 20% and 50% labels. Controlled comparisons show that the gain comes from the target. A temporal-median target with the same input, loss and budget stays at scratch level, and using the projection directly instead of learning it, as an input channel or a pseudo-label, helps little or hurts. ConPro provides pretrained weights without changing the segmentation architecture, so it combines with semi-supervised training, and UniMatch, the strongest baseline, gains 0.5 to 2.0 Dice and 0.9 to 2.3 clDice at every label fraction when started from ConPro weights, reaching 75.4 Dice on DIAS and 81.3 on DSCA.

0.31

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.61
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

Cross-Architectural Feature Fusion for Coronary Artery Stenosis Detection in X-ray Angiography

cs.CV ·2026-10-23 ·Haobo Zhu, Mojtaba Lashgari, Jason Chai, Giovanni Luigi De Maria, Vicente Grau +1 more
similarity 0.61
Abstract · 12 pages, 3 figures

Coronary artery disease remains a leading cause of mortality, with stenosis detection from invasive X-ray Coronary Angiography (XCA) critical for diagnosis. Manual interpretation is time-consuming, subjective, and variable, especially under low contrast and vessel overlap. Existing deep learning methods often rely solely on detection or segmentation, limiting performance. We propose a hybrid framework, Fusion-YOLOv11-L, combining a YOLOv11-L detector with a pretrained UNet++ via a channel attention gating module. This enables fusion of semantic and vessel-aware structural features, improving localisation of stenotic regions. The UNet++ is pretrained on ARCADE vessel segmentation dataset to provide anatomically informed representations. Experiments on the relabeled ARCADE (ARCADE*) dataset show improved performance over YOLOv11-L, achieving AP@50 of 0.585 and F1-score of 0.596. Cross-domain evaluation on a dataset from the Oxford Acute Myocardial Infarction (OxAMI) Study reveals performance degradation due to domain shift, mitigated using test-time adaptation and augmentation. Test-time augmentation improves AP@50 from 0.434 to 0.480, indicating better generalisability. These results show that cross-architecture feature fusion and lightweight adaptation improve robustness and generalisability of automated stenosis detection in XCA.

0.27