CS Paper Radar

TinyCardioUNet: IMU-to-ECG Translation with Graph-Encoded Inter-Axis Dependencies and Tensor Decomposition-Based Parameter Reduction

Seungwoo Han, Ingon Chanpornpakdi, Motoi Noda, Puwadej Leelasiri, Ibuki Hiruma, Toshihisa Tanaka

cs.LG ·submitted 2026-09-24 10:00 UTC · v1
code/data

Abstract

Estimating electrocardiography (ECG) from a chest-worn inertial measurement unit (IMU) enables continuous heart rate (HR) monitoring without the discomfort of electrodes. We propose TinyCardioUNet, a lightweight UNet that uses all six IMU axes without prior channel selection, refines its bottleneck with a graph neural network that encodes inter-axis dependencies, and employs tensor decomposition with automatic variational Bayesian rank selection for parameter reduction. On a public dataset, TinyCardioUNet achieves an RMSE of $0.098$ and a Pearson correlation coefficient of $0.677$ with only $36.0$k parameters and remains comparatively robust to additive noise, demonstrating accurate ECG reconstruction with a compact model.

Comment
The source code and pretrained models are available at https://github.com/ttlabtuat/TinyCardioUNet

Closest papers

Nearest neighbours by meaning across the whole index.

Accurate and Auditable ECG Classification via Visibility Graph Neural Networks

cs.LG cs.AI ·2026-10-30 ·Artur Xavier, Guilherme Henrique Gomes Evangelista, Aitazaz Khan, Antonio Luiz Pinho Ribeiro, Mohammed J. Zaki +2 more
hot direction similarity 0.61
Abstract · 43 pages, 10 figures, 21 tables, including Supplementary Information

Physicians read electrocardiograms (ECGs) from waveform shape and timing, yet accurate deep-learning classifiers rarely show which waveform regions drive their predictions. We introduce LYNX-ECG, a graph neural network that represents each heartbeat as a sparse visibility graph of timestamped turning points. On CODE-Test, LYNX-ECG reaches a macro F1 score of 0.889, outperforming five baselines including the ECGFounder foundation model, while its graphs need about 14% of the storage of graphs built from every sample. Because each node maps to a specific ECG time, we can delete clinically defined waveform regions and alter beat timing to audit predictions. For conduction disorders, the clinically expected region was the strongest evidence in more than 90% of correct predictions. Bradycardia and tachycardia calls follow heart rate with conduction intervals held fixed, and atrial fibrillation calls vanish when beat-to-beat variation is removed. Sparse visibility graphs thus pair accurate ECG classification with clinically grounded, testable explanations.

0.31

Analysis of Respiratory Sinus Arrhythmia with Neural Networks

cs.LG cs.AI ·2026-09-04 ·Julian Szymanski, Patryk Orkisz, Higinio Mora
top venue similarity 0.61
Abstract

The paper introduces a neural network-based approach for analyzing ECG signals to estimate respiratory rate by leveraging the phe- nomenon of Respiratory Sinus Arrhythmia (RSA). Our method employs a deep learning model trained to predict respiratory waveforms directly from ECG input data. To achieve this, we developed and evaluated three different neural network architectures capable of automatically extract- ing relevant features from ECG signals without the need for manual preprocessing. The proposed approach offers a robust and scalable solu- tion for non-invasive respiratory monitoring, with potential applications in healthcare and wearable technology

0.40

SSEMG-Net: A Spectrogram-Based Mamba Network for Surface Electromyography Denoising

eess.SP ·2026-09-10 ·Cheng-Han Shih, Kuan-Chen Wang, Kai-Chun Liu, Ping-Cheng Yeh, Yu Tsao
published similarity 0.60
Abstract · 6 pages, 3 figures, 2 tables. Presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society …

Electrocardiogram (ECG) artifact contamination frequently occurs in surface electromyography (sEMG) when muscles are recorded near the heart. Existing neural network (NN)-based approaches typically perform waveform-level end-to-end denoising with pointwise losses, but often fail to preserve the spectral structures of sEMG. In addition, these models do not exploit the prior knowledge that ECG mainly distorts the low-frequency band of sEMG. We propose SSEMG-Net, a spectrogram-domain model that explicitly captures sEMG-ECG interactions using a bidirectional Mamba backbone and a dual-head decoder for magnitude masking and wrapped-phase estimation. The magnitude masking module is physiologically aware, restricting denoising to the low-frequency sub-band where ECG activity predominates. Experimental results demonstrate that SSEMG-Net achieves superior signal quality and lower feature-extraction error compared to prior methods, underscoring its potential for clinical applications where preserving sEMG spectral features is essential.

0.44

Atrial Fibrillation Detection with Arbitrary Leads via a Codebook-Based Reconstruction-Classification Framework

cs.LG q-bio.QM ·2026-08-19 ·Hongtao Li, Jia Wei, Guoyao Li, Yuchen Lei, Guangnian Ma +4 more
benchmark similarity 0.60
Abstract

\textbf{Background and Objective}: Reliable atrial fibrillation (AF) detection from electrocardiogram (ECG) signals remains challenging in real-world clinical settings due to variable lead configurations, cross-dataset domain shifts, and pervasive physiological and technical artifacts. So we develop a robust and generalizable deep learning model for accurate AF detection.\\ \textbf{Methods}: We propose the Dual-Codebook Graph Collaborative Network (DCGCNet), a novel end-to-end vector-quantized variational autoencoder that jointly performs AF classification and ECG reconstruction. DCGCNet introduces two key components: (1) a Local-Global Contrastive Module for learning noise-invariant representations, and (2) an Adaptive Codebook Vector Quantizer that dynamically refines codebook prototypes to better align with input data distributions, thereby preventing codebook collapse and enhancing generalization.\\ \textbf{Results}: DCGCNet achieves state-of-the-art performance in standard intra-dataset 12-lead evaluation and demonstrates exceptional cross-dataset generalization across seven diverse settings, consistently attaining AUC > 0.98 in all cases. Furthermore, it maintains high diagnostic accuracy under realistic noisy conditions, including baseline wander, powerline interference, and EMG artifacts.\\ \textbf{Conclusions}: DCGCNet establishes a new benchmark for robust, generalizable, and noise-resilient AF detection, showing strong potential for deployment in real-world clinical environments.

0.15

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.59
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.59
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25

Graph-Based Pseudo-multimodal Contrastive Learning for 12-Lead ECG Representations

cs.LG ·2026-08-27 ·Mengyu Wang, Kozo Okada, Takafumi Goto, Natsuko Jinba, Hiroki Yamaya +2 more
published similarity 0.59
Abstract · 7 pages, 7 figures. Presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026…

12-lead electrocardiogram (ECG) is a standard, non-invasive examination widely used for diagnosing coronary artery disease, where clinical interpretation relies on comparing waveform patterns across multiple leads. However, most existing ECG analysis methods focus on single-lead signals or treat each lead independently, and typically process ECG signals as one-dimensional time-series data using CNNs or RNNs. While effective in modeling local waveform changes, such approaches have difficulty capturing inter-lead dependency and global waveform patterns essential for clinical diagnosis. To address this limitation, we propose a graph-based pseudo-multimodal contrastive learning framework called Graph-CMMC. ECG waveforms are transformed into Gramian Angular Difference Field (GADF) images to construct complementary representations of the same cardiac activity, enabling a pseudo-multimodal learning setting. Using all 12 leads, Graph-CMMC aligns waveform and GADF representations in a self-supervised manner, while a graph-based relational module is employed to model inter-lead dependency and enforce structural consistency across leads during contrastive learning. Experimental results on a multi-label coronary artery occlusion classification task demonstrate that the proposed framework achieves competitive performance compared to supervised learning methods. These results further suggest the effectiveness of using GADF as a complementary representation and incorporating explicit graph-based modeling of inter-lead dependency for learning robust 12-lead ECG representations.

0.32

Wearable ECG Quality Assessment: A Deep Learning and Ambulatory Context-Awareness Approach

cs.AI eess.SP ·2026-09-24 ·Xiaopeng Mao, Marike Weisbjerg, Sadasivan Puthusserypady
similarity 0.59
Abstract

This paper presents and evaluates a Deep Learning-based (DL-based) Signal Quality Assessment (SQA) model to distinguish between clean and noisy ambulatory Electrocardiograms (ECG). The model is trained on Copenhagen Center for Health Technology-Contextualized Arrhythmia Database (CACHET-CADB), which, to the best of our knowledge, is the first ambulatory ECG database with both physical and patient-reported contextual data. The model shows stable performance on different databases such as MIT-databases and the latest PyhsioNet/Cinc Challenge 2021 databases. Subsequently, the paper demonstrates how complicated ECG noise can be investigated by the SQA model and the physical contextual data.

0.08