CS Paper Radar

SSEMG-Net: A Spectrogram-Based Mamba Network for Surface Electromyography Denoising

Cheng-Han Shih, Kuan-Chen Wang, Kai-Chun Liu, Ping-Cheng Yeh, Yu Tsao

eess.SP ·submitted 2026-09-10 15:04 UTC · v1
published

Abstract

Electrocardiogram (ECG) artifact contamination frequently occurs in surface electromyography (sEMG) when muscles are recorded near the heart. Existing neural network (NN)-based approaches typically perform waveform-level end-to-end denoising with pointwise losses, but often fail to preserve the spectral structures of sEMG. In addition, these models do not exploit the prior knowledge that ECG mainly distorts the low-frequency band of sEMG. We propose SSEMG-Net, a spectrogram-domain model that explicitly captures sEMG-ECG interactions using a bidirectional Mamba backbone and a dual-head decoder for magnitude masking and wrapped-phase estimation. The magnitude masking module is physiologically aware, restricting denoising to the low-frequency sub-band where ECG activity predominates. Experimental results demonstrate that SSEMG-Net achieves superior signal quality and lower feature-extraction error compared to prior methods, underscoring its potential for clinical applications where preserving sEMG spectral features is essential.

Comment
6 pages, 3 figures, 2 tables. Presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

DR-net-Mamba: Selective State-Space Modeling for Long-Range ECG Time-Series Denoising

cs.LG cs.AI ·2026-09-28 ·Basile Morel, Samuel Ruiperez-Campillo, Andreas P. Streich, Julia E. Vogt, Thomas Hofmann
similarity 0.68
Abstract · First three authors are co-first. Last two authors are co-last

Electrocardiogram (ECG) recordings are corrupted by non-stationary noise sources that degrade diagnostic reliability, particularly in ambulatory and long-duration recordings. Deep learning denoisers exist, but convolutional architectures are limited by their receptive field, transformer-based models scale quadratically with sequence length, and diffusion-based approaches incur prohibitive inference cost. We propose a Mamba-augmented model that inserts selective state-space blocks at the convolutional bottleneck, combining local feature extraction with long-range temporal modeling at linear complexity. We comprehensively evaluate the proposed model with respect to reconstruction fidelity, noise robustness, recording-length scaling, and downstream diagnostic classification across over 40 pathology classes. On synthetic and real datasets, our model achieves the highest SNR and lowest RMSE, with the Mamba advantage increasing with sequence length and in low-SNR regimes. On classification with two independent classifiers, the proposed Mamba-based models achieve the best macro AUROC among all denoisers and improve over their convolutional base models. Calibration is more nuanced and classifier-dependent: denoising improves Binary Cross-Entropy and Brier score on Inception1D but often fails to beat the noisy input on ResNet1D-Wang, and the lead-specific Mamba variant is the only denoiser to improve both calibration metrics over the noisy baseline on both classifiers. Per-class analysis reveals a morphology-dependent benefit: Mamba substantially improves ST/T-change diagnoses, which depend on broad, context-sensitive waveforms.

0.07

Prism-SQA: An Interpretable and Adaptable Neural Framework for Surface Electromyography Quality Assessment

eess.SP cs.LG ·2026-09-11 ·Kuan-Chen Wang, Kai-Chun Liu, Ping-Cheng Yeh, Sheng-Yu Peng, Yu Tsao
published similarity 0.67
Abstract · 14 pages, 9 figures, 7 tables, accepted by IEEE Journal of Biomedical and Health Informatics (JBHI)

sEMG is vulnerable to various contaminants that distort signal morphology and spectral content. Accurate signal quality assessment (SQA) is essential for identifying such degradation and ensuring reliable clinical analyses and decisions. Recent neural network-based SQA methods achieve accurate quality estimation by learning complex contamination patterns, yet their black-box nature prevents clinicians from understanding or validating the reported scores and limits adaptability to application-specific quality definitions without retraining. To address these limitations, we propose Prism-SQA, an interpretable and adaptable neural framework that reformulates SQA as a physiology-aware source-separation and verification process. Prism-SQA decomposes each input signal into a clean sEMG component and five contaminant-specific components using a U-Net with bidirectional long short-term memory. Each separated contaminant component is examined by a Contaminant Fingerprint Verifier, which enforces physiological plausibility by comparing its temporal and spectral structure with canonical contaminant signatures. This design allows clinicians to inspect how each contaminant affects signal quality, grounding the assessment in transparent, signal-level evidence rather than opaque latent representations. Quality indices computed from the verified components further enable customization of quality criteria across clinical contexts without retraining. We evaluate Prism-SQA on continuous quality-score estimation using synthesized noisy sEMG from public Ninapro datasets and on binary quality classification using a clinical dysphagia dataset. Results show that Prism-SQA achieves competitive or better performance than contemporary black-box neural methods while providing explicit interpretability and adaptability, advancing toward practical and clinically aligned sEMG SQA.

0.65

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.65
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25

DiSR-ECG: Residual Shifting Conditional Diffusion for Robust ECG Super-Resolution

eess.SP ·2026-09-15 ·Fan-Yi Hsu, I Chiu, Kuan-Chen Wang, Sheng-Yu Peng, Yu Tsao
published similarity 0.64
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026)

Electrocardiogram (ECG) signals are essential for arrhythmia diagnosis. With the growing adoption of long-term monitoring via wearable and portable devices, energy-efficient acquisition has become critical, motivating the development of ECG super-resolution (SR) techniques to reconstruct high-resolution signals from low-sampling-rate inputs. While recent SR methods based on discriminative neural networks have shown strong performance, their robustness under distribution shift remains uncertain, which poses a key challenge for real-world deployment. In this study, we propose DiSR-ECG, a residual shifting conditional diffusion framework for robust ECG SR. The model integrates residual shifting with Mamba-based temporal modeling and conditional guidance to enable accurate multi-lead reconstruction. Experiments on two large-scale ECG databases, PTB-XL for in-domain evaluation and Chapman Shaoxing for cross-dataset evaluation, demonstrate that DiSR ECG achieves state-of-the-art performance in both settings, with particularly strong generalization under distribution shift. These results highlight the potential of DiSR-ECG to provide reliable and clinically applicable ECG reconstruction for real-world monitoring.

0.25

Decoder Design Matters for ECG Delineation

cs.LG cs.AI ·2026-09-15 ·Joseph Scharpf, William Han, Chaojing Duan, Michael A. Rosenberg, Emerson Liu +1 more
code/datahot direction similarity 0.62
Abstract · 5 pages, 3 figures

Electrocardiogram (ECG) delineation identifies the boundaries of P waves, QRS complexes, and T waves, providing structural annotations that can guide AI models in learning to interpret ECGs. However, training accurate delineation models requires manual annotations that are scarce and time-consuming to obtain. Recent work addresses this limitation through semi-supervised learning (SSL), but the design of the architecture, particularly the decoder, has received less attention. To this end, we propose R-U-Net, an ECG delineation model that pairs a ResNet-18 encoder with a U-Net decoder. On SemiSegECG, R-U-Net outperforms the strongest evaluated ResNet-18 + fully convolutional network (FCN) head baseline in each of the 16 in-domain settings by 3.3-13.0 mIoU and achieves 82.6 mIoU in the cross-domain setting, an improvement of 8.1 mIoU. Controlled ablations show that decoder design contributes more to performance gains than the evaluated SSL methods, motivating further exploration of architectures for ECG delineation. All code is open-source at github.com/ELM-Research/ECG-Delineation.

0.47

Deep Neural Networks for Learning Intent from sEMG Signals to Support Hardware Devices for Post-Stroke Neurorehabilitation

cs.LG ·2026-09-09 ·Zakariyya Brewster, Divy Wadhwani, Emily Yan, Aidan Wang, Karma Namgyal +3 more
hot direction similarity 0.61
Abstract

Finger-specific motor intent is a clinically meaningful control signal for post-stroke neurorehabilitation, where residual muscle activity may remain measurable despite weak or incomplete movement. We study five-finger multilabel intent decoding from impaired-arm high-density surface electromyography (sEMG) in PhysioMio, a bilateral longitudinal dataset collected from stroke patients. A common processing protocol aligns movement labels, applies 20--450 Hz Butterworth filtering and Symlet-4 wavelet denoising, segments overlapping 200 ms windows, and extracts twelve time- and frequency-domain descriptors per channel. Direct LSTM, CNN, and GNN baselines reveal complementary behavior: the LSTM attains the highest subset accuracy (0.545), whereas the GNN attains the highest macro F1 (0.706) and macro AUPRC (0.776). Architecture search then identifies CNN-Large as the strongest single-split CNN, with 0.593 subset accuracy and 0.714 macro F1, while CNN-Micro provides a compact architecture for embedded inference. To match a four-sensor hardware design, we retrain CNN-Micro using channels associated with ECRB, ECRL, FDS, and FDP and exclude the ground electrode from model input. Across five seeds, cross-channel knowledge distillation improves the four-channel student over direct training, reaching $0.5219 \pm 0.0114$ subset accuracy, $0.7612 \pm 0.0038$ finger accuracy, and $0.6095 \pm 0.0058$ macro F1. The selected 123K-parameter model accepts nine windows of 48 features and has been exported to ONNX. These results establish a reproducible software path from post-stroke sEMG to compact five-finger intent prediction for subsequent hardware-in-the-loop evaluation.

0.26

TinyCardioUNet: IMU-to-ECG Translation with Graph-Encoded Inter-Axis Dependencies and Tensor Decomposition-Based Parameter Reduction

cs.LG ·2026-09-24 ·Seungwoo Han, Ingon Chanpornpakdi, Motoi Noda, Puwadej Leelasiri, Ibuki Hiruma +1 more
code/data similarity 0.60
Abstract · The source code and pretrained models are available at https://github.com/ttlabtuat/TinyCardioUNet

Estimating electrocardiography (ECG) from a chest-worn inertial measurement unit (IMU) enables continuous heart rate (HR) monitoring without the discomfort of electrodes. We propose TinyCardioUNet, a lightweight UNet that uses all six IMU axes without prior channel selection, refines its bottleneck with a graph neural network that encodes inter-axis dependencies, and employs tensor decomposition with automatic variational Bayesian rank selection for parameter reduction. On a public dataset, TinyCardioUNet achieves an RMSE of $0.098$ and a Pearson correlation coefficient of $0.677$ with only $36.0$k parameters and remains comparatively robust to additive noise, demonstrating accurate ECG reconstruction with a compact model.

0.40

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

cs.LG ·2026-08-24 ·Wenhan Jiang, Zhipeng Deng, Jiale Zhou, Haolin Wang, Yafei Ou +1 more
top venue similarity 0.60
Abstract · Accepted at MICCAI 2026

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.

0.55