CS Paper Radar

Prism-SQA: An Interpretable and Adaptable Neural Framework for Surface Electromyography Quality Assessment

Kuan-Chen Wang, Kai-Chun Liu, Ping-Cheng Yeh, Sheng-Yu Peng, Yu Tsao

eess.SP cs.LG ·submitted 2026-09-11 11:23 UTC · v2
published

Abstract

sEMG is vulnerable to various contaminants that distort signal morphology and spectral content. Accurate signal quality assessment (SQA) is essential for identifying such degradation and ensuring reliable clinical analyses and decisions. Recent neural network-based SQA methods achieve accurate quality estimation by learning complex contamination patterns, yet their black-box nature prevents clinicians from understanding or validating the reported scores and limits adaptability to application-specific quality definitions without retraining. To address these limitations, we propose Prism-SQA, an interpretable and adaptable neural framework that reformulates SQA as a physiology-aware source-separation and verification process. Prism-SQA decomposes each input signal into a clean sEMG component and five contaminant-specific components using a U-Net with bidirectional long short-term memory. Each separated contaminant component is examined by a Contaminant Fingerprint Verifier, which enforces physiological plausibility by comparing its temporal and spectral structure with canonical contaminant signatures. This design allows clinicians to inspect how each contaminant affects signal quality, grounding the assessment in transparent, signal-level evidence rather than opaque latent representations. Quality indices computed from the verified components further enable customization of quality criteria across clinical contexts without retraining. We evaluate Prism-SQA on continuous quality-score estimation using synthesized noisy sEMG from public Ninapro datasets and on binary quality classification using a clinical dysphagia dataset. Results show that Prism-SQA achieves competitive or better performance than contemporary black-box neural methods while providing explicit interpretability and adaptability, advancing toward practical and clinically aligned sEMG SQA.

Comment
14 pages, 9 figures, 7 tables, accepted by IEEE Journal of Biomedical and Health Informatics (JBHI)

Closest papers

Nearest neighbours by meaning across the whole index.

SSEMG-Net: A Spectrogram-Based Mamba Network for Surface Electromyography Denoising

eess.SP ·2026-09-10 ·Cheng-Han Shih, Kuan-Chen Wang, Kai-Chun Liu, Ping-Cheng Yeh, Yu Tsao
published similarity 0.67
Abstract · 6 pages, 3 figures, 2 tables. Presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society …

Electrocardiogram (ECG) artifact contamination frequently occurs in surface electromyography (sEMG) when muscles are recorded near the heart. Existing neural network (NN)-based approaches typically perform waveform-level end-to-end denoising with pointwise losses, but often fail to preserve the spectral structures of sEMG. In addition, these models do not exploit the prior knowledge that ECG mainly distorts the low-frequency band of sEMG. We propose SSEMG-Net, a spectrogram-domain model that explicitly captures sEMG-ECG interactions using a bidirectional Mamba backbone and a dual-head decoder for magnitude masking and wrapped-phase estimation. The magnitude masking module is physiologically aware, restricting denoising to the low-frequency sub-band where ECG activity predominates. Experimental results demonstrate that SSEMG-Net achieves superior signal quality and lower feature-extraction error compared to prior methods, underscoring its potential for clinical applications where preserving sEMG spectral features is essential.

0.44

EEG-Xplain: Decoding Neural Black-Boxes of EEG Foundation Models

cs.AI ·2026-09-14 ·Hansong Ma, Junxiao Wang
benchmark similarity 0.58
Abstract

EEG foundation models such as BIOT, LaBraM, and EEGMamba have achieved remarkable performance in neural signal decoding, but their black-box nature limits clinical trust and neuroscientific validation. We propose a unified attribution framework for interpreting EEG foundation models across heterogeneous architectures. The framework integrates gradient-, perturbation-, and activation-based explanation methods to analyze model behavior in spatial, temporal, and frequency dimensions. Spatially, it identifies critical EEG channels and visualizes their distributions using topographic maps. Temporally, it highlights decision-relevant signal segments through attribution heatmaps. In the frequency domain, it quantifies the contributions of canonical EEG rhythms via spectral perturbation analysis. To assess explanation reliability, we introduce a population-level evaluation combining Area Over the Perturbation Curve (AOPC) and cross-method consistency analysis. The framework further leverages Large Language Models (LLMs) to transform structured attribution outputs into natural-language reports, bridging low-level neural representations and high-level semantic reasoning. Experiments on benchmark datasets, including Mumtaz2016 and TUAB, demonstrate that the generated explanations are consistent with established neurophysiological markers, validating meaningful neural representations while exposing potential dependencies on artifacts and spurious patterns. The proposed framework provides a standardized approach for evaluating the interpretability, reliability, and physiological plausibility of EEG foundation models.

0.31

Wearable ECG Quality Assessment: A Deep Learning and Ambulatory Context-Awareness Approach

cs.AI eess.SP ·2026-09-24 ·Xiaopeng Mao, Marike Weisbjerg, Sadasivan Puthusserypady
similarity 0.56
Abstract

This paper presents and evaluates a Deep Learning-based (DL-based) Signal Quality Assessment (SQA) model to distinguish between clean and noisy ambulatory Electrocardiograms (ECG). The model is trained on Copenhagen Center for Health Technology-Contextualized Arrhythmia Database (CACHET-CADB), which, to the best of our knowledge, is the first ambulatory ECG database with both physical and patient-reported contextual data. The model shows stable performance on different databases such as MIT-databases and the latest PyhsioNet/Cinc Challenge 2021 databases. Subsequently, the paper demonstrates how complicated ECG noise can be investigated by the SQA model and the physical contextual data.

0.08

Neuromotor Hierarchy Network: Physiological Inductive Biases for Robust Generalization in sEMG Decoding

cs.LG ·2026-10-06 ·He Wang, Hongyuan Qi, Zhaoxian Zhang, Jinbin Luo, Linyi He +2 more
similarity 0.56
Abstract · Adjust the authors info

Surface electromyography (sEMG) provides a wearable, noninvasive interface to neuromuscular activity for movement decoding and human-computer interaction. Population-scale decoding remains difficult because the relationship between sEMG and neuromuscular activity varies across users and sessions, while task-relevant dynamics span channels and multiple timescales. Learning waveform-to-output mappings from task labels leaves the distinction between recording variability and coordinated motor activity implicit. We introduce the Neuromotor Hierarchy Network (NHN), which learns a compact latent neuromotor state from task supervision to represent task-relevant neuromuscular coordination. NHN constructs this latent state through a hierarchy inspired by neuromotor organization. It adapts recording statistics while preserving relative intensity. Its spatiotemporal encoder uses parameter-efficient channel interactions and modulates features with multi-timescale history. The resulting features yield candidate activations of learned motor primitives, which are temporally integrated and continuously weighted to form the state. Theoretical analysis characterizes the efficiency, temporal behavior, and optimization of NHN's core mechanisms. We evaluate the architecture for both continuous hand-pose estimation on emg2pose and touch-typing recognition on emg2qwerty. On emg2pose, NHN reduces user-averaged angular error by 0.52% to 2.84% across all three generalization splits in both Regression and Tracking relative to Hadidi et al.'s best task-specific variants, using 48.42% to 48.51% fewer parameters. On emg2qwerty, NHN reduces beam-search character error rate by 19.40% zero-shot and 30.42% after fine-tuning relative to SplashNet-Upscale, using 65.86% fewer parameters. Physiology-guided inference of a latent neuromotor state supports parameter-efficient sEMG decoding.

0.18

A Proof-of-Concept Study of Weakly Supervised Labeling of Fine-Grained EEG Components for Artifact Attenuation

cs.LG eess.SP ·2026-10-07 ·Lu Wang-Nöth, Hai Huang, Philipp Heiler, Shuqiong Wu, Liyun Zhang +1 more
similarity 0.55
Abstract

Electroencephalography (EEG) is highly susceptible to electromyographic (EMG) artifacts, whose temporal heterogeneity and spatial-spectral overlap with neural activity can leave mixed sources after blind source separation. Existing artifact-removal methods are further limited by scarce reliable component-level ground truth: expert annotations are costly and subjective, while no established method provides realistic simulation-based ground truth for EMG contamination in multichannel scalp EEG. To address these limitations, we propose a framework combining a frequency-aware high-dimensional representation with Multi-Instance Learning. The representation unfolds separated components into frequency-resolved intra-components, creating a space in which mixed neural and muscular activity becomes more separable, while the weakly supervised learning formulation enables artifact-likelihood scores for individual intra-components to be learned from epoch-level labels without finer-grained ground truth. The resulting intra-component classifier supports fine-grained EMG artifact detection and score-guided attenuation. Experiments on held-out subjects show that the framework learns informative intra-component scores and reduces artifact-related spectral deviations most clearly for jaw tension, with moderate effects for raising eyebrows and limited effects for frowning.

0.12

Deep Neural Networks for Learning Intent from sEMG Signals to Support Hardware Devices for Post-Stroke Neurorehabilitation

cs.LG ·2026-09-09 ·Zakariyya Brewster, Divy Wadhwani, Emily Yan, Aidan Wang, Karma Namgyal +3 more
hot direction similarity 0.55
Abstract

Finger-specific motor intent is a clinically meaningful control signal for post-stroke neurorehabilitation, where residual muscle activity may remain measurable despite weak or incomplete movement. We study five-finger multilabel intent decoding from impaired-arm high-density surface electromyography (sEMG) in PhysioMio, a bilateral longitudinal dataset collected from stroke patients. A common processing protocol aligns movement labels, applies 20--450 Hz Butterworth filtering and Symlet-4 wavelet denoising, segments overlapping 200 ms windows, and extracts twelve time- and frequency-domain descriptors per channel. Direct LSTM, CNN, and GNN baselines reveal complementary behavior: the LSTM attains the highest subset accuracy (0.545), whereas the GNN attains the highest macro F1 (0.706) and macro AUPRC (0.776). Architecture search then identifies CNN-Large as the strongest single-split CNN, with 0.593 subset accuracy and 0.714 macro F1, while CNN-Micro provides a compact architecture for embedded inference. To match a four-sensor hardware design, we retrain CNN-Micro using channels associated with ECRB, ECRL, FDS, and FDP and exclude the ground electrode from model input. Across five seeds, cross-channel knowledge distillation improves the four-channel student over direct training, reaching $0.5219 \pm 0.0114$ subset accuracy, $0.7612 \pm 0.0038$ finger accuracy, and $0.6095 \pm 0.0058$ macro F1. The selected 123K-parameter model accepts nine windows of 48 features and has been exported to ONNX. These results establish a reproducible software path from post-stroke sEMG to compact five-finger intent prediction for subsequent hardware-in-the-loop evaluation.

0.26

SymKL: A Unified Representation-Space Measure of Signal Degradation

cs.CV cs.AI ·2026-10-29 ·Dhananjaya Jayasundara, Sudarshan Rajagopalan, Vishal M. Patel
code/dataunusual similarity 0.55
Abstract

Quantifying degradation between a pristine signal and its degraded observation is fundamental to signal processing, yet existing full-reference measures are inherently modality-specific. We introduce SymKL, a unified full-reference degradation measure based on implicit neural representations (INRs). An INR is fitted once to the pristine reference and characterized by its diagonal Fisher information, which captures the local information geometry of the learned representation. Evaluating the Fisher information with the pristine reference and a degraded observation yields two parameter-sensitivity profiles whose symmetric KL divergence defines the degradation score. The proposed formulation requires only the reference and degraded observation, without knowledge of the corruption process or degradation severity, making it applicable across images, audio, and 3D data. We further derive an exact closed-form expression for the diagonal Fisher of SIREN, enabling efficient computation. Experiments on image, speech, and volumetric 3D benchmarks demonstrate that SymKL accurately tracks degradation severity, remains monotonic where conventional metrics saturate or fail, and provides a unified modality-agnostic measure of signal degradation. Code will be made publicly available after the review process.

0.36

Beyond Reconstruction: A Unified Framework for Trustworthy and Explainable EEG Artifact Removal Evaluation

eess.SP cs.AI ·2026-11-16 ·Phat Lam, Hung Nguyen, Lam Pham, Huy Phan, Dat Tran +3 more
similarity 0.55
Abstract · IEEE journal manuscript under review

Deep-learning methods have achieved strong performance in EEG artifact removal, but evaluation remains dominated by reconstruction metrics such as error, correlation, and signal-to-noise ratio. Although these metrics assess similarity to clean EEG, they do not establish whether models effectively suppress artifacts, preserve neural activity, or provide reliable explanations. To address these limitations, we propose TriX-EEG, a three-level framework for trustworthy and explainable EEG artifact removal. Level 1, Signal Validity (SV), evaluates reconstruction quality and neural band-power preservation. Level 2, Removal Faithfulness (RF), assesses the removed component through artifact error and residual artifact/neural leakage. Level 3, Explanation Reliability (ER), examines model behavior through temporal alignment, causal relevance, and stability. We evaluate TriX-EEG using nine published neural denoisers across three public benchmarks derived from EEGDenoiseNet and the PhysioNet Motion Artifact Contaminated EEG Dataset, covering EOG, EMG, and motion artifacts. Results show that reconstruction metrics alone are insufficient for trustworthy denoiser assessment: RF complements it by revealing whether errors stem from residual artifact or suppressed neural activity, while ER captures distinct aspects of explanation behavior, supporting joint evaluation of three aspects within a unified framework rather than reliance on any single factor. External validation on an independent EEG/EOG dataset and the BCI Competition IV-2a motor-imagery dataset further demonstrates broadly consistent rankings under dataset shift. Higher-ranked denoisers generally preserve more task-relevant information or cause less downstream performance degradation. Overall, TriX-EEG provides a comprehensive basis for EEG denoiser assessment, encouraging models that are not only accurate but also faithful and explainable.

0.27