WIPSNet: Deep Learning for Paediatric Wheeze Detection from Overnight Impedance Pneumography

Felix Oury, Harley Day, Karina Mayoral, Ville-Pekka Seppä, Sejal Saglani, Reiko J. Tanaka

cs.LG eess.SP ·submitted 2026-09-30 11:58 UTC · v1
publishedcode/data

Abstract

Overnight impedance pneumography (IP) is used to monitor paediatric respiratory health. Its current clinical readout, the Expiratory Variability Index (EVI), compresses each IP recording into a single scalar and achieves an AUC of 0.633 for night-level wheeze classification. We introduce Wheeze Impedance Pneumography Scalogram Network (WIPSNet), a 3D ResNet operating on stacked continuous wavelet transform scalograms of overnight IP signals. On a 15-patient cohort (60 nights, 281 hours), WIPSNet achieves an AUC of $0.783 \pm 0.026$, outperforming EVI, a state-space model (Mamba), and two modern sleep-staging architectures. Performance peaks at a volumetric depth corresponding to 32 minutes of temporal context, suggesting that multi-scale temporal aggregation is important for modelling nocturnal respiratory dynamics. Overall, these results indicate that structured time-frequency representations combined with 3D convolutional architectures provide an effective approach for learning from long, irregular physiological time series.

Comment
Accepted at the Workshop on Structured Data for Health, ICML 2026. Code: https://github.com/felix-oury/WIPSNet

Closest papers

Nearest neighbours by meaning across the whole index.

RespFocus: Learning Temporal Evidence for Weakly Supervised Respiratory Sound Classification

cs.LG cs.AI ·2026-10-11 ·Yi Tian, Xiaohuan Chen, Yufei tang, Xinyu Lin, Hongliang Li +3 more
similarity 0.65
Abstract · 9 pages, 5 figures,2 tables

Respiratory auscultation provides a low-cost means of assessing pulmonary function, yet transient crackles and sustained wheezes can be difficult to recognize in noisy clinical recordings. Conventional deep learning classifiers often operate as black boxes, offering limited insight into the temporal acoustic evidence supporting their predictions. We present RespFocus, a weakly supervised framework that uses multiple instance learning (MIL) to learn inspectable temporal evidence from cycle-level labels and integrate it into classification. We also introduce PedResp2026, a multicenter pediatric respiratory sound cohort collected in routine clinical environments with adjudicated cycle-level annotations. In classification experiments, RespFocus achieves four-class Scores of 69.55\% on public ICBHI 2017 and 72.91\% on PedResp2026. Evidence diagnostics and matched temporal interventions support the functional contribution of the learned evidence to model predictions. Together, these findings highlight RespFocus's potential as a tool for automated respiratory sound diagnosis.

0.30

Acoustic Respiratory Phase Detection on Mobile Devices

cs.AI cs.LG ·2026-11-12 ·Julian Szymanski, Tomasz Sankowski, Piotr Sulewski, Iwo Czartowski, Javier Medina Quero
similarity 0.64
Abstract

Breathing monitoring is important for well-being, stress regulation, and guided breathing exercises, yet existing approaches often rely on contact-based sensors or controlled environments. This paper presents a non-invasive framework for respiratory phase detection using acoustic signals recorded on commodity smartphones. The proposed hybrid CNN-Transformer architecture combines local spectral feature extraction with long-range temporal modeling to capture the cyclic structure of breathing. The model is evaluated using a Leave-One-Subject-Out (LOSO) protocol on the Foundation Dataset and on an independent unseen test set comprising over 1300 breathing cycles and 2 hours of continuous recordings. The proposed 3-class formulation achieves 72.85% frame-level accuracy and 96.6% cycle-level exhalation detection efficiency in the LOSO evaluation, while achieving 76.94% frame-level accuracy, a Cohen's Kappa score of 0.65, and 99.2% cycle-level exhalation detection efficiency on the unseen test set. Results suggest that accurate respiratory monitoring may be achievable under data-constrained conditions, indicating that appropriate temporal modeling can learn transferable respiratory representations and generalize to previously unseen participants. An end-to-end ONNX deployment pipeline enables privacy-preserving on-device inference with latency below 20 ms, supporting real-time monitoring on mobile and wearable devices.

0.18

Design and Architecture of Airmod: An Active Noise Cancellation and Deep Learning System for Real-Time Respiratory Rate Estimation from Tracheal Sounds

cs.SD ·2026-10-27 ·Shang-Ran Huang, Fu-Shun Hsu, Ji-Chang Huang, Chuan Chen, Shou-Zen Fan +3 more
similarity 0.64
Abstract

Tracheal auscultation is recommended by clinical practice guidelines, and required by some U.S. state regulations, for monitoring ventilation during procedural sedation and monitored anesthesia care. However, continuous auscultation with a conventional stethoscope is impractical, susceptible to ambient noise, and difficult to interpret. We developed the Artificial Intelligence Respiratory MOnitoring Device (Airmod), an FDA-cleared software as a medical device (510(k) K242798) that continuously monitors tracheal sounds and estimates breath-to-breath respiratory rate in real time. In this paper, we describe its software architecture and key processing modules. Ambient noise is suppressed by active noise control, using a normalized least-mean-square adaptive filter with a dual-microphone electronic stethoscope. A multiclass convolutional bidirectional gated recurrent unit (CNN-BiGRU) model detects inhalations and exhalations in 15-s inference windows. It was trained on HF_Tracheal_V2, a new database of 373 continuous tracheal sound recordings (8,521 min; 107,644 labeled inhalations) from 369 subjects under sedation. To handle continuous acoustic streaming, Airmod runs inference on overlapping 15-s windows. It refines the detected inhalations by removing incomplete events, low-energy false positives, and double counts, concatenates them into a history list, and estimates respiratory rate from the mean period of the last three breaths. On the test set, at the default 2-s prediction interval with refinement enabled, inhalation detection achieved a sensitivity of 0.828, a positive predictive value of 0.832, and an F1-score of 0.830. Airmod also broadcasts the noise-cancelled tracheal sound and displays a real-time spectrogram to help clinicians recognize respiratory abnormalities.

0.21

AF-Mamba: Efficient Long-Term Signal Modeling for Early Prediction of Atrial Fibrillation Onset

cs.LG ·2026-09-07 ·Yongbin Lee, Ki H. Chon
code/data similarity 0.63
Abstract · 11 pages, 5 figures, 7 tables. Extended version of IEEE BSN 2025. Code: https://github.com/yongbin98/AF_Mamba

Atrial fibrillation (AF) is the most common cardiac arrhythmia and is associated with increased risks of stroke and heart failure. The growing availability of wearable and portable ECG monitoring enables continuous assessment of cardiac rhythm outside clinical settings. Predicting AF before its onset could provide additional lead time for timely clinical assessment and potentially improve the management of patients at risk of AF-related complications. This study focuses on predicting AF onset one hour in advance using long-term RR intervals (RRIs). To address this challenge, we propose a deep learning architecture that integrates temporal convolutional networks (TCNs) for local features encoding with Mamba, a selective state-space model capable of long-range sequence modeling. This hybrid TCN-Mamba design enables efficient training and inference on one-hour input windows, overcoming limitations of Transformers' quadratic scaling and recurrent networks' vanishing gradients. In subject-wise 5-fold testing, the proposed model achieved a sensitivity of 0.889, specificity of 0.943, F1-score of 0.813, AUROC of 0.974, and AUPRC of 0.933. In paired cross-dataset holdout evaluation, AF-Mamba maintained discriminative performance across unseen AF and NSR datasets, achieving a mean AUROC of 0.897. Compared against state-of-the-art AF prediction models and general time-series models, AF-Mamba achieved competitive predictive performance while providing a favorable performance-efficiency trade-off for long RRI sequences. These findings demonstrate the potential of AF-Mamba for accurate AF prediction one hour in advance and real-time continuous ambulatory monitoring.

0.38

Time-Aware Tranformer-Based Prediction Model for AECOPD

cs.LG ·2026-08-21 ·Weihao Qu, Ling Zheng, Dongyang Wang, Jiacun Wang, Haowen Pan
publishedcode/data similarity 0.62
Abstract · 5 pages, 1 figure, 1 table. Published in MEDINFO 2025

The rapid symptom change of Acute exacerbation of chronic obstructive pulmonary disease (AECOPD) makes it critical to have time-sensitive prediction models. However, most current machine learning models studying AECOPD use clinical and laboratory data, which will inevitably cause latency. To ensure timely detection of AECOPD and minimize latency, this paper focuses on home monitoring scenarios where only respiratory data from daily-use ventilators is available. We introduce a Time-Aware transformer-based AECOPD prediction model, which generates meaningful patient representations using the Time-Aware transformer to capture the symptoms and their temporal progression in ventilator data. Our experimental results demonstrate that our Time-Aware transformer-based approach outperforms traditional methods in multiple classification tasks, highlighting its potential to enhance AECOPD prediction accuracy.

0.62

Breath-Dx: A Time Series Classification Benchmark for Disease Screening with eNose

cs.LG cs.AI ·2026-11-11 ·Ivan Poddiakov, Ivan Kruzhilov, Galina Zubkova, Svetlana Erofeeva, Andrey Savchenko +1 more
publishedbenchmarkdatasetcommunity pick similarity 0.62
Abstract · IEEE ICDM 2026 - Best Paper Runner-Up (Applied Track)

Electronic nose (eNose) technology offers a portable, non-invasive route for disease screening via exhaled breath analysis. However, progress in the field is hindered by the lack of systematic benchmarks that compare machine learning methods under realistic conditions, particularly sensor drift, a known but rarely quantified failure mode. Most existing studies rely on small, private datasets with inconsistent protocols, rendering results non-comparable and slowing progress. We introduce Breath-Dx, the first comprehensive benchmark of time series classification methods for breath-based disease screening. Our work leverages the Scent of Health (S-OH) dataset, the largest public clinical eNose collection to date, comprising 1,234 patients across nine diagnostic groups, each providing a 17-channel multivariate time series with explicit temporal train/test splits that account for sensor drift. We systematically evaluate 10 methods spanning four families: feature-based tabular learners, convolution-based models, graph-based, and time series architectures. All methods degrade significantly under temporal validation (0.05-0.12 AUC drop compared to random cross-validation), confirming that drift embeds a strong temporal signal. Under this realistic evaluation, the best methods achieve ROC AUC of 0.74-0.76 for some lung conditions, though others remain near chance. Recurrent architectures show the most consistent performance across diseases, while specialized time series methods achieve the highest peak results. Demographic confounders matter: breath signals provide independent diagnostic value for some conditions but add little beyond age for others. We release the S-OH dataset, all temporal splits, evaluation protocols, and code to enable reproducible research and accelerate progress in clinical breathomics.

0.43

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

cs.LG cs.AIcs.SD ·2026-10-12 ·Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi
similarity 0.61
Abstract

Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.

0.13

NanoSleep: A Parameter-Efficient Hybrid Temporal Convolutional Network for Single-Channel Sleep Stage Classification

cs.LG ·2026-08-19 ·S M Asif Hossain, Shruti Kshirsagar
similarity 0.61
Abstract

Sleep stage classification from single-channel electroencephalography (EEG) is essential for wearable and home-based sleep monitoring. However, many deep learning models achieve high accuracy at the cost of large model sizes, which limits their deployment on resource-constrained devices. In this work, we present NanoSleep, a compact hybrid temporal convolutional network for automatic sleep stage classification. NanoSleep combines a learnable Sinc-convolutional front end, a dual-branch feature extractor that fuses multi-scale temporal and spectral representations, a gated dilated temporal convolutional backbone with channel recalibration, and a conditional random field for sequence-level decoding. We further employ a weighted calibrated focal loss to address class imbalance. We evaluate NanoSleep on the Sleep-EDF and Sleep-EDF-Expanded datasets using subject-wise cross-validation. The proposed model consistently outperforms six representative baseline methods, and an ablation study confirms the contribution of each major component. These results demonstrate that NanoSleep provides an effective balance between accuracy and efficiency, making it well suited for wearable devices, home-based sleep monitoring, and resource-constrained clinical applications.