CS Paper Radar

Daily listing

2026-09-24 · eess.SP

38 papers first submitted this day (UTC) in eess.SP — Signal Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

AI & Machine Learning 2

A Contraction Framework for Stochastic Operators with Bootstrapping: Application to TD Learning

cs.LG eess.SPmath.OC ·2026-09-24 ·Ids van der Werf, Sergio Rozada, Antonio G. Marques
Abstract · 5 pages, 1 figure

Many iterative algorithms rely on bootstrapping. A variable is updated using a second, frozen copy as a target, which is periodically replaced with the updated variable. Majorize-minimize and inexact proximal-point methods share this structure, as does temporal-difference (TD) learning. However, existing convergence guarantees for scenarios that combine sampled updates with targets refreshed only every $K$ steps rely on the specific structure of the update, such as linear approximation or gradient-based inner steps, and on uniformly bounded sampling error. We instead model the sampled update as a stochastic operator on the parameter space, which reduces the analysis to a contraction argument that needs no gradient structure and allows the sampling error to grow with the iterates. Within this framework, we derive a finite-time bound for i.i.d. samples and any target-update period $K$. We show that the iterates converge geometrically in root mean square to a ball around the fixed point, provided the sensitivity to the frozen target is smaller than the contraction slack of the inner map. Existing deterministic frozen-target contraction and stochastic-gradient-type bounds follow as special cases of our framework, and simulations of TD learning reproduce the predicted contraction rate and scaling of the error floor with the step size.

0.21

Wearable ECG Quality Assessment: A Deep Learning and Ambulatory Context-Awareness Approach

cs.AI eess.SP ·2026-09-24 ·Xiaopeng Mao, Marike Weisbjerg, Sadasivan Puthusserypady
Abstract

This paper presents and evaluates a Deep Learning-based (DL-based) Signal Quality Assessment (SQA) model to distinguish between clean and noisy ambulatory Electrocardiograms (ECG). The model is trained on Copenhagen Center for Health Technology-Contextualized Arrhythmia Database (CACHET-CADB), which, to the best of our knowledge, is the first ambulatory ECG database with both physical and patient-reported contextual data. The model shows stable performance on different databases such as MIT-databases and the latest PyhsioNet/Cinc Challenge 2021 databases. Subsequently, the paper demonstrates how complicated ECG noise can be investigated by the SQA model and the physical contextual data.

0.08