AI & Machine Learning 5

Expert-level detection of low-voltage intervals in EEG as a robust biomarker of neonatal encephalopathy

cs.LG eess.SPphysics.med-ph ·2026-10-08 ·John M. O'Toole, Sean R. Mathieson, Aurel Luca, Soraia Ventura, Sean Griffin +2 more
benchmark
Abstract · 22 pages, 8 figures, and 9 tables including the appendix. Under review

Background: Discontinuity in neonatal EEG is a critical marker of brain dysfunction but can be difficult to quantify visually. Inter-burst intervals (IBIs) are a key characteristic of discontinuity, yet their definition does not easily translate to AI detection. Objectives: To introduce low-voltage intervals (LVIs), defined exclusively by amplitude and duration, as a context-independent alternative to IBIs, develop an AI detection method for LVIs, and assess their clinical utility as a marker of brain injury. Methods: We developed a ConvNeXt model to detect LVIs and compared its performance with existing methods. We then tested the clinical relevance of detected LVIs across four applications: 1) grading background EEG abnormalities on an open benchmark dataset, 2) classifying clinical hypoxic-ischaemic encephalopathy (HIE) grades and comparing with a normal EEG dataset, 3) seizure prediction, and 4) association with seizure burden. Results: For training and validation, 654 hours of per-channel EEG from 123 neonates were reviewed and 51,162 LVIs were annotated. On held-out validation, ConvNeXt had an AUC of 0.996 and a Matthews correlation coefficient of 0.926. Model-reader agreement exceeded inter-reader agreement ($Δκ= 0.025$, 95% CI: 0.007 to 0.045, $p<0.001$), attaining expert-level equivalence. On a combined dataset of 444 neonates, percentage LVI showed a strong association with EEG grades (Spearman's $ρ=0.801$), a moderate association with HIE grades ($ρ=0.384$), a weaker association with seizure burden ($ρ=0.244$), and a strong seizure prediction capacity (AUC $=0.872$). Conclusion: AI detection of LVIs achieves expert-level equivalence, whereas quantitative features do not. Automated LVI quantification provides a robust clinical biomarker of neonatal encephalopathy associated with background EEG activity, HIE severity, and seizure risk.

0.43

Differentiable Systematic Resampling for Variational Sequential Monte Carlo

cs.LG stat.MLeess.SP ·2026-10-08 ·Fredrik Cumlin, Saikat Chatterjee
top venuetheory
Abstract · Accepted to NeurIPS 2026

Particle filters are a standard tool for nonlinear state estimation, but their resampling step is discrete, preventing gradient-based learning in variational sequential Monte Carlo. We introduce Differentiable Systematic Resampling (DSR), a temperature-controlled relaxation of systematic resampling, that preserves the CDF-ordered, banded structure of systematic resampling while enabling full gradient flow. DSR converges to exact systematic resampling as the temperature vanishes, and we prove a pointwise exponential convergence rate for the induced bias. Compared to optimal-transport-based differentiable resampling, DSR avoids iterative solvers and has substantially lower computational overhead. Experiments on stochastic dynamical systems and real-world handwriting data show that DSR achieves comparable or superior filtering and dynamics learning performance.

0.35

Instruction-Conditioned Electromagnetic Spectrum Understanding via Budget-Adaptive Signal Tokenization

cs.AI eess.SP ·2026-10-08 ·Lei Zhai, Zhihao Chang, Shuyuan Yang, Zhixi Feng
Abstract

Electromagnetic spectrum monitoring increasingly requires flexible analysis beyond task-specific recognition and detection. Multimodal large language models offer a unified interface, but extending vision-language models (VLMs) to raw I/Q signals requires tokenization that balances fidelity against a strict budget. For signals, dense encoding causes token costs to grow with observation length, whereas fixed-resolution compression may discard short-duration or localized signal evidence. Thus, we propose \textbf{BATok}, a budget-adaptive signal tokenizer that adjusts token capacity to the input length while allocating that capacity according to the signal content. BATok constructs candidate representations from signal-derived features using lightweight multi-resolution branches, then combines a local energy prior with learnable queries to resample these representations into compact signal tokens. The number of tokens adapts to the input length while remaining strictly bounded. The resulting tokens are projected into the language embedding space of VLMs. We further introduce \textbf{EMSpec-Instruct}, a multimodal instruction dataset aligning raw I/Q signals, waterfall images, and language supervision for modulation recognition, structured detection, and language-conditioned signal grounding. Experiments show that BATok learns effective signal representations and achieves competitive performance across all tasks.

0.24

A Group-Aware Comparative Study of Classical Machine Learning and Deep Learning Methods for Sensor-Based Human Activity Recognition

cs.LG cs.AIeess.SP ·2026-10-08 ·Wahyu Pebrianto
Abstract

Human Activity Recognition (HAR) using wearable or smartphone inertial sensors is commonly evaluated with both classical machine learning and deep learning methods. However, reported performance can be strongly affected by sensor modality, dataset characteristics, and data-splitting strategy. This study presents a controlled comparative evaluation of four classical machine learning models and four deep learning models on two public HAR datasets, UCI-HAR and KU-HAR. Three sensor modalities were considered: accelerometer (ACC), gyroscope (GYRO), and their combination (ACC+GYRO). Classical machine learning models used handcrafted statistical features, while deep learning models operated directly on raw sensor sequences. The primary evaluation employed five-fold StratifiedGroupKFold cross-validation, with subject- or participant-level grouping to prevent group overlap between training and test folds. Macro-F1 was used as the primary performance metric. The results show that deep learning did not consistently outperform classical machine learning. On UCI-HAR, the evaluated deep learning models achieved slightly higher macro-F1 values, whereas on KU-HAR, LightGBM achieved 0.857 compared with 0.828 for the highest-performing evaluated deep learning model. Regarding sensor modality, the combined ACC+GYRO configuration generally outperformed ACC or GYRO alone on both datasets. The evaluation protocol also had a substantial effect: for CNNBiLSTMAttn with ACC+GYRO, random splitting increased macro-F1 by 0.033 on UCI-HAR and 0.093 on KU-HAR compared with grouped evaluation. These findings highlight the importance of model family, sensor modality, dataset characteristics, and group-aware evaluation when assessing sensor-based HAR systems.

0.14

Self-Supervised Speech Representations for Cross-Speaker Dysarthria Detection During Awake Craniotomy

cs.LG cs.SDeess.SP ·2026-10-08 ·Kanthila Chinmayi, Abdallah Nassib, Misy Harrison, Panheleux Celine, Saliou Vanessa +2 more
Abstract

Detecting intra-operative speech impairment during awake craniotomy is essential for preserving language function. However, automated detection remains challenging because operating-room recordings contain substantial acoustic interference, clinically relevant speech events are rare, and available cohorts are small and heterogeneous across speakers. This study presents a systematic component-wise evaluation of a pipeline for distinguishing dysarthric from no-trouble speech in the DATABRASE corpus of awake-craniotomy recordings. The pipeline incorporates speaker diarization to isolate patient speech, a multi-view representation combining handcrafted acoustic descriptors with multilayer wav2vec 2.0 embeddings, speaker-conditional normalization and transferability-based feature selection to improve cross-speaker robustness, and a cascaded classifier comprising a gradient-boosted first stage and a neural second stage. Evaluation was conducted under strict speaker-independent conditions using leave-one-speaker-out cross-validation. The results show that cross-speaker performance is influenced more strongly by the speech representation than by classifier choice. The AUCs of three classifiers differed by no more than 4.7%, whereas replacing conventional acoustic descriptors with the multilayer self-supervised representation produced AUC improvements of 18.2%-26.1%. Diarization-conditioned feature extraction and the proposed classifier cascade provided additional consistent gains. These findings indicate that reliable patient-specific speech isolation and strong pretrained representations are more important than increased classifier complexity in low-resource intra-operative settings. They also quantify the potential performance gains that may be achieved through patient-specific preoperative calibration.

0.09