Background: Discontinuity in neonatal EEG is a critical marker of brain dysfunction but can be difficult to quantify visually. Inter-burst intervals (IBIs) are a key characteristic of discontinuity, yet their definition does not easily translate to AI detection. Objectives: To introduce low-voltage intervals (LVIs), defined exclusively by amplitude and duration, as a context-independent alternative to IBIs, develop an AI detection method for LVIs, and assess their clinical utility as a marker of brain injury. Methods: We developed a ConvNeXt model to detect LVIs and compared its performance with existing methods. We then tested the clinical relevance of detected LVIs across four applications: 1) grading background EEG abnormalities on an open benchmark dataset, 2) classifying clinical hypoxic-ischaemic encephalopathy (HIE) grades and comparing with a normal EEG dataset, 3) seizure prediction, and 4) association with seizure burden. Results: For training and validation, 654 hours of per-channel EEG from 123 neonates were reviewed and 51,162 LVIs were annotated. On held-out validation, ConvNeXt had an AUC of 0.996 and a Matthews correlation coefficient of 0.926. Model-reader agreement exceeded inter-reader agreement ($Δκ= 0.025$, 95% CI: 0.007 to 0.045, $p<0.001$), attaining expert-level equivalence. On a combined dataset of 444 neonates, percentage LVI showed a strong association with EEG grades (Spearman's $ρ=0.801$), a moderate association with HIE grades ($ρ=0.384$), a weaker association with seizure burden ($ρ=0.244$), and a strong seizure prediction capacity (AUC $=0.872$). Conclusion: AI detection of LVIs achieves expert-level equivalence, whereas quantitative features do not. Automated LVI quantification provides a robust clinical biomarker of neonatal encephalopathy associated with background EEG activity, HIE severity, and seizure risk.

Comment
22 pages, 8 figures, and 9 tables including the appendix. Under review

Closest papers

Nearest neighbours by meaning across the whole index.

U-NeXt: General-purpose event detection for neonatal EEG

cs.LG eess.SPphysics.med-ph ·2026-10-23 ·Robert Hogan, Sean R. Mathieson, Aurel Luca, Soraia Ventura, Sean Griffin +2 more
similarity 0.71
Abstract

We developed U-NeXt, a general framework for neonatal electroencephalography (EEG) event detection based on semantic segmentation. Its convolutional encoder-decoder directly segments individual channels using long input segments to preserve temporal context. A shared architecture and training framework were developed using low-voltage interval, artefact, and seizure datasets containing 51, 98, and 278 neonates, respectively, comprising over 11,000 hours of EEG and 82,000 annotated events. Performance was compared with task-specific ConvNeXt classifiers. For seizure detection, we also evaluated U-NeXt+, trained on an expanded dataset. Both U-NeXt variants and the ConvNeXt baseline were evaluated on two independent held-out seizure datasets, Helsinki and Cork, comprising 130 neonates, with recordings annotated by three experts. U-NeXt improved detection across all three event types, with particular gains in sensitivity for short events. U-NeXt+ achieved Matthews correlation coefficients of 0.862 and 0.891 on Helsinki and Cork, respectively, and improved hourly seizure burden correlations by 30-40% relative to ConvNeXt. U-NeXt+ met the criterion for expert-level performance on both datasets (p < 0.001). In separate computational benchmarks, U-NeXt reduced batch inference time relative to ConvNeXt by 254-fold on a central processing unit and 200-fold on a graphics processing unit. A common segmentation framework improves detection across diverse neonatal EEG event types while substantially reducing inference time. Accurate seizure burden estimates and performance comparable to expert reviewers support its potential use in continuous monitoring and clinical decision support.

0.12

Best Practices in EEG Analysis: Preprocessing, Modeling, and Machine Learning

eess.SP cs.LG ·2026-09-29 ·Parsa Razmara, Woojae Jeong, Aditya Kommineni, Raymundo Cassani, Richard Leahy +1 more
published similarity 0.66
Abstract · 38 pages, 5 figures. Chapter 16 of the 2026 monograph "Electroencephalogram Signals and Cognition," edited by Hema A. Murthy, Shrikanth Nara…

Electroencephalography (EEG) analysis requires careful choices in preprocessing, statistical modeling, and machine learning because EEG signals are highly susceptible to artifacts, volume conduction, low signal-to-noise ratio, and substantial inter-subject variability. This chapter provides a practical and methodological guide to modern EEG analysis, spanning EEG preprocessing, artifact removal, filtering, bad-channel detection and interpolation, re-referencing, independent component analysis (ICA), and preprocessing of simultaneous EEG-fMRI recordings. We review major approaches for computational EEG analysis, including event-related potentials (ERPs), time-frequency analysis, functional and effective connectivity, source localization, multivariate decoding, permutation testing, and multiple-comparison correction. We then examine machine-learning methods for EEG, from feature-based classifiers to deep learning and emerging EEG foundation models, with emphasis on cross-subject generalization, limited-data regimes, data leakage, evaluation metrics, and fair benchmarking. Reproducibility is treated as a core requirement throughout, including transparent preprocessing, BIDS-EEG data organization, standardized derivatives, preservation of raw data, and FAIR data practices. The chapter is intended as a practical reference for researchers developing reliable, interpretable, and reproducible EEG analysis and machine-learning pipelines.

0.27

OOD Detection for EEG-based Machine Learning in High-Risk Environments

cs.LG ·2026-08-18 ·Philipp Bomatter, Henry Gouk
benchmark similarity 0.66
Abstract

Machine learning models for electroencephalography (EEG) analysis show great promise across a wide range of applications, but their deployment in high-risk domains is hindered by their vulnerability to distribution shifts. Encountering out-of-distribution (OOD) data can lead to catastrophic, overconfident predictive failures. While OOD detection methods can mitigate these risks, they remain heavily under-explored for EEG. Moreover, evaluations in the broader literature typically evaluate OOD detection performance in isolation, ignoring their practical impact on downstream applications. To bridge this gap, we introduce a benchmark for EEG OOD detection, evaluate a broad range of methods, and furthermore evaluate their value in two clinical downstream prediction task. Our results disentangle OOD detection and model uncertainty estimation capabilities, which are frequently conflated in the literature, provide actionable insights about the current state of the art for EEG OOD detection and model uncertainty estimation, and demonstrate how complementary methods for both aspects can be combined to form a robust safety net for the deployment of EEG-based machine learning models in real-world applications.

0.13

EEGBind: Detecting Source-Level Interictal Epileptiform Discharges via EEG-Centric Multimodal Binding

cs.LG cs.MMq-bio.NC ·2026-09-09 ·Muchen Li, Anglin Liu, Xuetian Gao, Ruijian Xu, Jintai Chen
top venuebenchmarkcode/data similarity 0.64
Abstract · 7 pages, 5 figures. Accepted to the 34th ACM International Conference on Multimedia (MM '26)

Source-level analysis of interictal epileptiform discharges (IEDs) is relevant to presurgical evaluation and treatment planning because it helps characterize where epileptiform activity is likely to arise. Beyond detecting whether an IED is present, this setting requires assigning IED-positive activity to clinically meaningful brain-region categories. This setting is challenging because source-region evidence in short electroencephalography (EEG) windows can be subtle, partial, and affected by subject variability, class imbalance, and imperfect multimodal context. We present EEGBind, an EEG-centric multimodal binding framework for five-class source-level IED classification. EEGBind treats EEG as the primary modality and binds synchronized video-context features around an EEG-centric representation. Instead of relying on early or overly strong multimodal fusion, which may perturb the source-sensitive EEG representation, EEGBind uses video context as auxiliary evidence for robust classification. A view-consistent repair stage is further used to improve hidden-set robustness while preserving the learned source-class boundary. On the NeuroMM 2026 Grand Challenge Track 3 NMM-Source-IED benchmark, EEGBind achieves 0.8395 on weighted-F1 and outperforms strong competitors. These results support EEG-centric multimodal binding as a practical strategy for source-level IED classification. The open-source code is available at https://github.com/HKUSTGZ-ML4Health-Lab/NeuroMM2026_IED_Detection.

0.55

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.63
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

RobustSeiz: An Open-Source Framework for Benchmarking the Robustness of EEG Seizure Detection Models

cs.LG eess.SP ·2026-09-03 ·Mohammad Mohammadi, Alireza Zarei
code/data similarity 0.61
Abstract · 28 pages, 13 numbered figures, 9 tables; full-page graphical abstract and supplementary material included. Submitted to the Journal of the A…

Despite strong performance on held-out electroencephalography (EEG) data, seizure detectors may fail under real-world acquisition variability, artifacts, and adversarial inputs. We introduce RobustSeiz, an open-source, model-agnostic framework that provides a standardized, reproducible protocol for stress-testing and comparing seizure detectors under controlled, clinically motivated distribution shifts before deployment. We standardize four public scalp-EEG corpora (CHB-MIT, TUSZ, Siena, and SeizeIT1) into BIDS-EEG trees and evaluate subject-independent detectors on held-out splits. Environment, noise, and adversarial transforms are swept over predefined hyperparameter grids. Each run reports sample- and event-level sensitivity, precision, F1, false positives per 24 h, Lead and Lag onset timing, and Monte Carlo dropout predictive agreement. RobustSeiz includes a Dockerized GPU pipeline, experiment registry, and full-evaluation and research-subset modes. We demonstrate the framework with a contemporary seizure detector on TUSZ across the complete implemented shift grid; an AWGN analysis illustrates how perturbation severity changes detection quality, onset timing, and predictive agreement. RobustSeiz provides a shared benchmarking standard for evaluating seizure-detector robustness under realistic clinical stressors, extending pre-deployment assessment beyond clean-data accuracy.

0.22

Towards Modality-Agnostic Seizure Classification: A Unified Deep Learning Framework for Heterogeneous EEG and Intracranial EEG Signals

cs.LG cs.AI ·2026-10-12 ·Ramya Sundaram, Muhammad Aslam Jarwar, M Uma, Sunder Ali Khowaja, Qurat-Ul-Ain Mastoi
similarity 0.60
Abstract

Seizure prediction and detection, essential for clinical treatment of epilepsy, remain the crucial task of this neurological disease. EEG and iEEG are widely used to analyze epilepsy due to its capability of capturing discriminative brain activities at high time resolution. However, existing works generally analyze either EEG or iEEG seizure activity separately, where EEG analysis has been well-researched, while more and more works consider iEEG for its higher specificity at the spatial level and signal quality. Currently, most of the existing seizure prediction systems are single-modal in nature, which limits its application to a variety of clinical conditions. Therefore, a common framework to analyze seizures with both EEG and iEEG signals needs to be developed. This paper presents a new framework of multimodal seizure classification integrating the heterogeneous EEG and iEEG recordings from different subjects and sources. A specific framework, called Unified Multimodal Signal Harmonization (UMSH), is developed for harmonizing signals with varied sampling rates and recording conditions. Moreover, to handle the extremely class-imbalanced problem in the data sets, we use a Conditional Generative Adversarial Network (cGAN) based data augmentation technique to generate synthetic samples to balance the class distribution. The proposed framework uses the EEGNet-Vision Transformer (EEGNet-ViT) as the feature extraction and classification network to learn the local discriminative patterns as well as global contextual information in the multimodal seizure data. Experimental results demonstrate the effectiveness of the proposed framework for robust seizure classification, emphasizing the potential of integrated EEG-iEEG multimodal learning in advancing next-generation epilepsy monitoring and clinical decision-support systems.

0.11

Predicting Only from Selected Evidence: A Tempered Product-of-Experts Bottleneck for Auditable EEG Diagnosis

eess.SP ·2026-08-25 ·Yinghao Wang, Shujian Yu, Duc Han Le, Zhikai Yu, Changming Wang +1 more
similarity 0.59
Abstract

Pretrained EEG backbones improve transfer performance, but downstream diagnosis heads remain hard to audit: predictions are made from unrestricted hidden states, whereas explanations are usually produced only after the decision. We introduce tPoE-EIB, an evidence-information bottleneck head for adapting EEG backbones under an evidence-only prediction constraint. tPoE-EIB selects temporal and channel evidence, maps the selected summaries to Gaussian experts over a shared latent variable, and fuses them with a tempered product-of-experts posterior. The classifier observes only this latent, so the decision path is explicit and rate-limited by the expected posterior KL. This gives a tractable supervised objective with an information-rate penalty, while the closed-form tempered posterior mitigates overconfident fusion from correlated evidence axes. We evaluate tPoE-EIB on pretrained EEG foundation-model backbones across six diagnosis settings: event-type classification, abnormality detection, seizure detection, cognitive-decline staging, depression screening, and cerebrovascular-disease classification. The evaluation spans public benchmarks and in-house clinical cohorts, binary screening and fine-grained staging, and sparse and dense montages. tPoE-EIB preserves competitive balanced accuracy and improves over representative post-hoc explanations on selection-faithfulness audits, including insertion-deletion and gate-causality tests. Its structured posterior further enables integration-faithfulness audits, including expert-drop, posterior-reliance, and expert-disagreement tests. Overall, these results suggest that evidence-only, rate-limited fusion is a practical route to auditable diagnosis on top of frozen EEG foundation backbones.