CS Paper Radar

EEGBind: Detecting Source-Level Interictal Epileptiform Discharges via EEG-Centric Multimodal Binding

Muchen Li, Anglin Liu, Xuetian Gao, Ruijian Xu, Jintai Chen

cs.LG cs.MMq-bio.NC ·submitted 2026-09-09 05:15 UTC · v1
top venuebenchmarkcode/data

Abstract

Source-level analysis of interictal epileptiform discharges (IEDs) is relevant to presurgical evaluation and treatment planning because it helps characterize where epileptiform activity is likely to arise. Beyond detecting whether an IED is present, this setting requires assigning IED-positive activity to clinically meaningful brain-region categories. This setting is challenging because source-region evidence in short electroencephalography (EEG) windows can be subtle, partial, and affected by subject variability, class imbalance, and imperfect multimodal context. We present EEGBind, an EEG-centric multimodal binding framework for five-class source-level IED classification. EEGBind treats EEG as the primary modality and binds synchronized video-context features around an EEG-centric representation. Instead of relying on early or overly strong multimodal fusion, which may perturb the source-sensitive EEG representation, EEGBind uses video context as auxiliary evidence for robust classification. A view-consistent repair stage is further used to improve hidden-set robustness while preserving the learned source-class boundary. On the NeuroMM 2026 Grand Challenge Track 3 NMM-Source-IED benchmark, EEGBind achieves 0.8395 on weighted-F1 and outperforms strong competitors. These results support EEG-centric multimodal binding as a practical strategy for source-level IED classification. The open-source code is available at https://github.com/HKUSTGZ-ML4Health-Lab/NeuroMM2026_IED_Detection.

Comment
7 pages, 5 figures. Accepted to the 34th ACM International Conference on Multimedia (MM '26)
DOI
10.1145/3767308.3837697

Closest papers

Nearest neighbours by meaning across the whole index.

Towards Modality-Agnostic Seizure Classification: A Unified Deep Learning Framework for Heterogeneous EEG and Intracranial EEG Signals

cs.LG cs.AI ·2026-10-12 ·Ramya Sundaram, Muhammad Aslam Jarwar, M Uma, Sunder Ali Khowaja, Qurat-Ul-Ain Mastoi
similarity 0.71
Abstract

Seizure prediction and detection, essential for clinical treatment of epilepsy, remain the crucial task of this neurological disease. EEG and iEEG are widely used to analyze epilepsy due to its capability of capturing discriminative brain activities at high time resolution. However, existing works generally analyze either EEG or iEEG seizure activity separately, where EEG analysis has been well-researched, while more and more works consider iEEG for its higher specificity at the spatial level and signal quality. Currently, most of the existing seizure prediction systems are single-modal in nature, which limits its application to a variety of clinical conditions. Therefore, a common framework to analyze seizures with both EEG and iEEG signals needs to be developed. This paper presents a new framework of multimodal seizure classification integrating the heterogeneous EEG and iEEG recordings from different subjects and sources. A specific framework, called Unified Multimodal Signal Harmonization (UMSH), is developed for harmonizing signals with varied sampling rates and recording conditions. Moreover, to handle the extremely class-imbalanced problem in the data sets, we use a Conditional Generative Adversarial Network (cGAN) based data augmentation technique to generate synthetic samples to balance the class distribution. The proposed framework uses the EEGNet-Vision Transformer (EEGNet-ViT) as the feature extraction and classification network to learn the local discriminative patterns as well as global contextual information in the multimodal seizure data. Experimental results demonstrate the effectiveness of the proposed framework for robust seizure classification, emphasizing the potential of integrated EEG-iEEG multimodal learning in advancing next-generation epilepsy monitoring and clinical decision-support systems.

0.11

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.70
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

Best Practices in EEG Analysis: Preprocessing, Modeling, and Machine Learning

eess.SP cs.LG ·2026-09-29 ·Parsa Razmara, Woojae Jeong, Aditya Kommineni, Raymundo Cassani, Richard Leahy +1 more
published similarity 0.67
Abstract · 38 pages, 5 figures. Chapter 16 of the 2026 monograph "Electroencephalogram Signals and Cognition," edited by Hema A. Murthy, Shrikanth Nara…

Electroencephalography (EEG) analysis requires careful choices in preprocessing, statistical modeling, and machine learning because EEG signals are highly susceptible to artifacts, volume conduction, low signal-to-noise ratio, and substantial inter-subject variability. This chapter provides a practical and methodological guide to modern EEG analysis, spanning EEG preprocessing, artifact removal, filtering, bad-channel detection and interpolation, re-referencing, independent component analysis (ICA), and preprocessing of simultaneous EEG-fMRI recordings. We review major approaches for computational EEG analysis, including event-related potentials (ERPs), time-frequency analysis, functional and effective connectivity, source localization, multivariate decoding, permutation testing, and multiple-comparison correction. We then examine machine-learning methods for EEG, from feature-based classifiers to deep learning and emerging EEG foundation models, with emphasis on cross-subject generalization, limited-data regimes, data leakage, evaluation metrics, and fair benchmarking. Reproducibility is treated as a core requirement throughout, including transparent preprocessing, BIDS-EEG data organization, standardized derivatives, preservation of raw data, and FAIR data practices. The chapter is intended as a practical reference for researchers developing reliable, interpretable, and reproducible EEG analysis and machine-learning pipelines.

0.47

A Proof-of-Concept Study of Weakly Supervised Labeling of Fine-Grained EEG Components for Artifact Attenuation

cs.LG eess.SP ·2026-10-07 ·Lu Wang-Nöth, Hai Huang, Philipp Heiler, Shuqiong Wu, Liyun Zhang +1 more
similarity 0.66
Abstract

Electroencephalography (EEG) is highly susceptible to electromyographic (EMG) artifacts, whose temporal heterogeneity and spatial-spectral overlap with neural activity can leave mixed sources after blind source separation. Existing artifact-removal methods are further limited by scarce reliable component-level ground truth: expert annotations are costly and subjective, while no established method provides realistic simulation-based ground truth for EMG contamination in multichannel scalp EEG. To address these limitations, we propose a framework combining a frequency-aware high-dimensional representation with Multi-Instance Learning. The representation unfolds separated components into frequency-resolved intra-components, creating a space in which mixed neural and muscular activity becomes more separable, while the weakly supervised learning formulation enables artifact-likelihood scores for individual intra-components to be learned from epoch-level labels without finer-grained ground truth. The resulting intra-component classifier supports fine-grained EMG artifact detection and score-guided attenuation. Experiments on held-out subjects show that the framework learns informative intra-component scores and reduces artifact-related spectral deviations most clearly for jaw tension, with moderate effects for raising eyebrows and limited effects for frowning.

0.12

Predicting Only from Selected Evidence: A Tempered Product-of-Experts Bottleneck for Auditable EEG Diagnosis

eess.SP ·2026-08-25 ·Yinghao Wang, Shujian Yu, Duc Han Le, Zhikai Yu, Changming Wang +1 more
similarity 0.66
Abstract

Pretrained EEG backbones improve transfer performance, but downstream diagnosis heads remain hard to audit: predictions are made from unrestricted hidden states, whereas explanations are usually produced only after the decision. We introduce tPoE-EIB, an evidence-information bottleneck head for adapting EEG backbones under an evidence-only prediction constraint. tPoE-EIB selects temporal and channel evidence, maps the selected summaries to Gaussian experts over a shared latent variable, and fuses them with a tempered product-of-experts posterior. The classifier observes only this latent, so the decision path is explicit and rate-limited by the expected posterior KL. This gives a tractable supervised objective with an information-rate penalty, while the closed-form tempered posterior mitigates overconfident fusion from correlated evidence axes. We evaluate tPoE-EIB on pretrained EEG foundation-model backbones across six diagnosis settings: event-type classification, abnormality detection, seizure detection, cognitive-decline staging, depression screening, and cerebrovascular-disease classification. The evaluation spans public benchmarks and in-house clinical cohorts, binary screening and fine-grained staging, and sparse and dense montages. tPoE-EIB preserves competitive balanced accuracy and improves over representative post-hoc explanations on selection-faithfulness audits, including insertion-deletion and gate-causality tests. Its structured posterior further enables integration-faithfulness audits, including expert-drop, posterior-reliance, and expert-disagreement tests. Overall, these results suggest that evidence-only, rate-limited fusion is a practical route to auditable diagnosis on top of frozen EEG foundation backbones.

0.24

iEEG Can Help EEG: Improving Clinical Scalp EEG Analysis through Intracranial Priors

cs.LG eess.SPq-bio.NC ·2026-11-16 ·Xianglong Bao, Yi Ding, Zengxiang Li, Nan Liu, Kewen Wang +2 more
top venuecode/data similarity 0.66
Abstract · Accepted at KDD 2027

Scalp electroencephalography (EEG) is a cornerstone of clinical brain monitoring, making the quality of its signal fundamental to downstream tasks and models. However, that signal is heavily contaminated by non-neural interference and blurred by volume conduction. Existing methods operate almost exclusively within the scalp modality, so they inherit the contamination they would need to overcome. In practice, intracranial EEG (iEEG) observes the neural activity with far higher fidelity, yet it is invasive and therefore scarce, and the two modalities are rarely recorded as pairs at scale, share no common channel space, and offer no clean ground truth to directly supervise a mapping. Motivated by the neuronal synchronization mechanism shared by the two modalities, we propose a reprogramming approach that fits a signal-to-signal model on iEEG alone and freezes it as a cross-modal prior. We introduce ReBrain, a framework to transfer an iEEG-learned prior to scalp EEG, which re-expresses any scalp signal through that prior and can be inserted upstream of any downstream model with no pairing or fine-tuning. ReBrain consistently improves host models across recordings from multiple hospitals and across architecture families, and our analysis traces this gain to genuine neural structure carried by iEEG rather than to the architecture itself. This work provides evidence that a scarce clean modality can serve as a transferable prior for an abundant noisy one, offering a general recipe for cross-modal transfer among biosignals. Our code is available at https://github.com/Xianglong-Bao/ReBrain.

0.62

Virtual iEEG from Scalp EEG: Charting the Landscape of Source Imaging, Intracranial Inference and Reconstruction

cs.CV ·2026-08-27 ·Dongyi He, Xiangkai Wang, Hongjie Yan, Luping Song, Wai Ting Siok +1 more
similarity 0.66
Abstract

Intracranial electroencephalography (iEEG) provides temporally precise and spatially specific access to neural activity from focal and deep brain regions, but its invasiveness and restricted anatomical coverage limit routine use. These constraints have motivated scalp-to-intracranial inference, termed virtual iEEG when model outputs carry iEEG-defined event, feature, representation, or contact-level waveform semantics. This review presents a target-centred framework distinguishing event inference, feature translation, and waveform reconstruction, while separating predictability from observability, identifiability, fidelity, and utility. Evidence is evaluated according to cohort independence, anatomical and spectral coverage, train--test separation, and target-patient adaptation. Current studies support inference of selected intracranial events, low-frequency components, and task-related representations, but not unique recovery of arbitrary contact-level activity. Stronger validation requires appropriate controls, source-imaging baselines, uncertainty assessment, and incremental-utility testing. Future progress depends on independent paired datasets and prospective evidence that virtual iEEG adds value beyond scalp EEG and EEG source imaging.

0.22

RobustSeiz: An Open-Source Framework for Benchmarking the Robustness of EEG Seizure Detection Models

cs.LG eess.SP ·2026-09-03 ·Mohammad Mohammadi, Alireza Zarei
code/data similarity 0.65
Abstract · 28 pages, 13 numbered figures, 9 tables; full-page graphical abstract and supplementary material included. Submitted to the Journal of the A…

Despite strong performance on held-out electroencephalography (EEG) data, seizure detectors may fail under real-world acquisition variability, artifacts, and adversarial inputs. We introduce RobustSeiz, an open-source, model-agnostic framework that provides a standardized, reproducible protocol for stress-testing and comparing seizure detectors under controlled, clinically motivated distribution shifts before deployment. We standardize four public scalp-EEG corpora (CHB-MIT, TUSZ, Siena, and SeizeIT1) into BIDS-EEG trees and evaluate subject-independent detectors on held-out splits. Environment, noise, and adversarial transforms are swept over predefined hyperparameter grids. Each run reports sample- and event-level sensitivity, precision, F1, false positives per 24 h, Lead and Lag onset timing, and Monte Carlo dropout predictive agreement. RobustSeiz includes a Dockerized GPU pipeline, experiment registry, and full-evaluation and research-subset modes. We demonstrate the framework with a contemporary seizure detector on TUSZ across the complete implemented shift grid; an AWGN analysis illustrates how perturbation severity changes detection quality, onset timing, and predictive agreement. RobustSeiz provides a shared benchmarking standard for evaluating seizure-detector robustness under realistic clinical stressors, extending pre-deployment assessment beyond clean-data accuracy.

0.22